期刊文献+

大型锅炉水冷壁高温腐蚀分析及改进措施 被引量:28

The high temperature corrosion on water cooled wall in large-scale boiler and its improvement
下载PDF
导出
摘要 针对石门电厂锅炉水冷壁存在的高温腐蚀现象 ,通过高温腐蚀垢样分析断定硫化物型高温腐蚀 ,从煤的含硫量、煤质特性、炉内切圆大小、一次风气流偏转贴墙情况、煤粉细度等方面分析了水冷壁发生高温腐蚀的原因 ,研究认为靠近水冷壁的还原性气氛是造成高温腐蚀的重要原因 ,针对具体原因 ,提出了一次风反切、侧边风技术。 In the view of high temperature corrosion on water cooled wall in the furnace, the type of high temperature corrosion was described by analyzing corrosive product. Several aspects of high temperature corrosion on the water cooled walls were investigated such as the content of sulfur, circle diameter, velocity of primary air, coal quantity, fineness of pulverized coal. The main reason of the high temperature corrosion was the near-wall reducing gas. Some measures were put forward to improve it.
出处 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2004年第3期20-22,共3页 Journal of Huazhong University of Science and Technology(Natural Science Edition)
关键词 大型锅炉水冷壁 高温腐蚀 还原性气氛 反切 large-scale boiler water cooled wall high temperature corrosion reducing gas anti-tangent
  • 相关文献

参考文献4

二级参考文献23

  • 1丘纪华,陈刚,李佛金,孙学信.应用计算机模拟技术分析预测炉内煤粉燃烧过程[J].中国电机工程学报,1995,15(5):306-310. 被引量:10
  • 2高桥恭郎(日) 等.PM型低NOx燃烧器的开发[J].三菱重工技报,1981,18(5).
  • 3谏壁发电厂 能源部西安热工所.谏壁发电厂1000t/h直流炉水冷壁烟侧高温腐蚀的原因分析和防治[M].,1992,6..
  • 4朱彤.直流燃烧器结构与运行参数对炉内空气动力场影响的研究.哈尔滨工业大学博士学位论文[M].,1997,6..
  • 5上海锅炉厂.石洞口发电厂1025t/h直流锅炉水冷壁高温腐蚀情况及冶标工作总结[M].,1991..
  • 6赵宗让 章明川.四角切圆燃烧锅炉煤粉射流逆向稳燃技术的研究开发.锅炉燃烧技术学术会议论文集[M].中国动力工程学会,1996,8..
  • 7哈尔滨工业大学 山东工业大学 等.青岛发电厂300MW机组2号炉改造水冷壁防高温腐蚀.燃烧调速试验及低负荷试验报告[M].,1998,10..
  • 8山东电力科学研究院.青岛发电厂1号燃烧调整试验报告[M].,1997,10..
  • 9岑可法,锅炉和热交换器的积灰、结渣、磨损和腐蚀的防止原理与计算,1994年
  • 10哈尔滨工业大学,燃烧调整试验及低负荷试验报告,1998年,10页

共引文献34

同被引文献211

引证文献28

二级引证文献155

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部