期刊文献+

镉镍电池中锂含量的测定 被引量:2

Determination of lithium contents in Ni/Cd battery
下载PDF
导出
摘要 用N2O C2H2火焰原子吸收光谱法进行镉镍电池中锂含量的测定。该方法具有灵敏度高、选择性好、操作步骤简单、容易掌握等特点,达到了实验室分析质量的控制,适用于对镉镍电池中锂含量的控制分析和样品系统分析。 The application of N_2O-C_2H_2 flame atomic absorption spectrometry to measure the content of lithium in Ni/Cd batteries was studied. The method had the advantages of high sensitivity. This method was proved to be simple, easy and short analyzing cycle, less interference and good in selectivity and reproducibility.
作者 薛光荣
出处 《电池》 CAS CSCD 北大核心 2004年第2期147-148,共2页 Battery Bimonthly
关键词 镉镍电池 锂含量 测定 原子吸收光谱法 电解液 蓄电池 N_2O-C_2H_2 flame atomic absorption spectrometry Ni/Cd battery lithium
  • 相关文献

参考文献3

  • 1Kellner R, Merment J.Chemical analysis [M].New York: Scientific Publishing Company, 1995.155-266.
  • 2Cramer J M. Atomic absorption spectrometry [ M].New York: Scientific Publishing Company, 1982. 281-326.
  • 3Pearl C. Quantitative chemical analysis [ M ]. New York: Scientific Publishing Company, 1969. 253-285.

同被引文献16

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部