摘要
采用等离子体原子发射光谱法测定添加剂中硼含量。硼元素是一种易挥元素,所以本方法采用密闭压力溶弹法处理样品,元素没有损失。本文对方法的准确度、精密度以及检测下限进行了论述。
This method is applied to measure the content of element B with ICP/AES in the additive.
Element B is easy to volatilize. So high pressure airtight tank is a good tool to treat samples,and element
will not be lost. The accuracy,the precision precision and lowest detected limitation are discussed in this ar--
ticle.
出处
《渤海大学学报(自然科学版)》
CAS
2004年第2期112-114,共3页
Journal of Bohai University:Natural Science Edition