期刊文献+

经棘突内固定技术的研究及进展 被引量:7

下载PDF
导出
出处 《中国矫形外科杂志》 CAS CSCD 2004年第10期777-779,共3页 Orthopedic Journal of China
  • 相关文献

参考文献18

  • 1Coe JD,Warden KE,Herzig MA,et al. Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws,laminar hooks, and spinous process wires[J]. Spine,1990,15:902~907.
  • 2Graft H. Lumbar instability surgical treatment without fusion:Soft system stabilization[J]. Rachis,1992,4:123~137.
  • 3Duncan ET, Shepherd PhD,Johanna C, et al. Spinous process strength[J]. Spine,2000,25(3):319~323.
  • 4Grob D, Criso J,Panjabi MM,et al.Biomechanical evalution of four different posterior atlanto-axial fixation technique[J]. Spine,1991,17:480~490.
  • 5Hajek PD, Lipka J,Hartline P, et al. Biomechanical study of C1~C2 posteror arthrodesis technique[J]. Spine,1993,18:173~177.
  • 6Richter M, Schmidt R,Claes L,et al. Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques[J]. Spine,2002,27(16):1724~1732.
  • 7瞿东滨,金大地,赵卫东,钟世镇.Biomechanical evaluation of atlantoaxial transarticular screw fixation technique[J].Chinese Journal of Traumatology,2000,3(2):89-92. 被引量:1
  • 8Simmons ED Jr, Burke TG,Haley T,et al.Biomechanical comparison of the dewar and interspinous cervical spine fixation techniques[J]. Spine,1996,21(3):295~298.
  • 9Neuwirth MG, Drummond DS,et al.The results of interspinous segmental instrumentation in the sagittal plane[J]. J Spinal Disord,1993,6(1):1~4.
  • 10Noel SH, Keene JS, Rice WL.Improved postoperative course after spinous process segmental instrumentation of thoracolumbar fractures[J]. Spine,1991,16(2):132~136.

二级参考文献9

  • 1洪天禄,唐天驷,董天华.节段性不稳在脊椎滑脱症外科治疗中的临床意义[J].中华骨科杂志,1996,16(7):412-414. 被引量:86
  • 2黄令坚,郑文忠.钳夹式多爪棘突固定器的研制[J].骨与关节损伤杂志,1996,11(6):374-374. 被引量:9
  • 3赵定麟.脊柱脊髓损伤救治基本原则[J].骨与关节损伤杂志,1996,11(4):194-196. 被引量:20
  • 4唐天驷,钱忠来.腰椎崩裂和滑脱症[J].中华骨科杂志,1997,17(1):5-7. 被引量:138
  • 5Marcotte P,Dickman CA,Sonntag VKH,et al.Posterior atlantoaxial facet screw fixation[].Journal of Neurosurgery.1993
  • 6Stillerman CB,Wlson JA.Atlantoaxial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases[].Neurosurgery.1993
  • 7Grob D,Crisco III J,Panjabi MM,et al.Biomechanical evaluation of four different posterior atlantoaxial fixation techniques[].SPINE.1992
  • 8Madawi AA,Casey ATH,Solanki GA,et al.Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique[].Journal of Neurosurgery.1997
  • 9Handson PB,Montesano PX,Sharkey NA,et al.Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability[].SPINE.1991

共引文献11

同被引文献147

  • 1刘刚,颜连启,郭开今,陈幽婷,袁峰,辛兵,施伟.腰椎棘突间区的解剖学参数及临床意义[J].解剖与临床,2006,11(1):10-13. 被引量:9
  • 2乐增年,欧阳甲,Allen Carl.腰椎小关节螺钉内固定[J].中国矫形外科杂志,2006,14(23):1837-1838. 被引量:1
  • 3Bono CM, Vaccaro AR. Interspinous process devices in the lumbar spine. J Spinal Disord Tech 2007;20(3):255-261.
  • 4Kondrashov DG, Hannibal M, Hsu KY, et al. Interspinous process decompression with the X-STOP device for lumbar spinal stenosis (A 4-Year Follow-Up Study). J Spinal Disord Tech 2006; 19:323-327.
  • 5Zucherman JF, Hsu KY, Hartjen CA, et al. A multicenter, prospective, randomized trial evaluating the X-STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication: two-year follow-up results. Spine 2005;30:1351 - 1358.
  • 6Anderson PA, Tribus CB, Kitchel SH. Treatment of neurogenic claudication by interspinous decompression: application of the X STOP device in patients with lumbar degenerative spondylolisthesis. J Neurosurg Spine 2006:4:463-464.
  • 7Phillips FM, Voronov LI, Gaitanis IN, et al. Biomechanics of posterior dynamic stabilizing device (DIAM) after facetectomy and discectomy. Spine J 2006;6(6):714-722.
  • 8Caserta S, La Maida GA, Misaggi B, et al. Elastic stabilization alone or combined with rigid fusion in spinal surgery: A biomechanical study and clinical experience based on 82 cases. Eur Spine J 2002; 11 (suppl):S 192-S 197.
  • 9Schmoelz W, Huber JF, Nydegger T, et al. Influence of a dynamic stabilisation system on load bearing of a bridged disc: an in vitro study of intradiscal pressure. Eur Spine J 2006; 15:1276-1285.
  • 10Kong DS, Kim ES, Eoh W. One-year outcome evaluation after interspinous implantation for degenerative spinal stenosis with segmental instability. J Korean Med Sci 2007;22(2):330-335.

引证文献7

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部