摘要  介绍了离子迁移谱仪嵌入式系统工作原理及其核心部件嵌入式处理器和操作系统的选择,对系统的硬件结构和软件任务模块设计作了重点阐述,特别是对系统的核心CPU处理模块及关键技术作了详细介绍。 This paper presents the working principle of the IONSCAN embedded system and the selecting of an embedded processor as well as an embedded operating system.The paper also describes the design of a hardware and software task module,especially puts stress on the CPU-processing module and key techniques used in the system.
出处 《工业仪表与自动化装置》 2004年第3期67-69,43,共4页 Industrial Instrumentation & Automation
基金 国家"十五"攻关项目(2001BA801B05)
关键词 嵌入式 波峰位置 离子信号 迁移时间 embedded crest location ion signal mobile time
  • 相关文献

参考文献2

二级参考文献7

  • 1[1]Jack Ganssle.Changes in Embedded Design Methodolody,Embedded Systems Programming[M].Sept 1998.
  • 2[2]David Stepner and Nagrajan Rajan and David Hui,Embedded Application Design Using a Real-Time OS.36th Design Automation Conference,Proceedings 1999.
  • 3[3]Robert RichardsDesigning RTOS for Embedded Microcontrollers,Embedded systems Programming[M].May 1997.
  • 4[4]Doug Brown.Solving the Software Safety Paradox,Embedded Systems Programming[M].Dec 1998.
  • 5[5]Shaul Gal-Oz.The Hazards of Device Driver Design,Embedded Systems Programming[M].May 1997.
  • 6[6]Daniel Mann.An Uncommon ISR Technique,Embedded Systems Programming[M].Jan 1995.
  • 7[7]David Lafreniere.An Efficient Dynamic Storage Allocator,Embedded systems Programming[M].Sept 1998.

共引文献9

同被引文献18

  • 1邬小平,王学武,谢亚丽,陈志强,张丽.基于贝叶斯决策的双能X射线材料分辨算法研究[J].中国体视学与图像分析,2003,8(3):162-165. 被引量:7
  • 2许峰,王海龙,关亚风.离子迁移谱研究进展[J].化学进展,2005,17(3):514-522. 被引量:40
  • 3汤昕烨,张丽,陈志强,高河伟,张国伟.双能DR物质识别算法在CT成像系统中的应用[J].中国体视学与图像分析,2007,12(2):88-92. 被引量:5
  • 4Eiceman G. A., Karpas Z.. Ion Mobility Spectrometry (ist Edition) [M].Boca Raton, CRC Press, 1994.
  • 5H. H. Herbert, F.S. William, H.S.L. Robert, Anal. Chem., 62, 1208A (1990).
  • 6G. W. Griffin, I. Dzidic, D.I. Carroll, R.N. Stillwell, E.C. Horning, Anal. Chem., 45, 1204 (1973).
  • 7Ochoa M L., Harrington P. B.. Detection of methamphetamine in the presence of nicotine using in situ chemical derivatization and ion mobility spectrometry [J]. Anal. Chem., 2004, 76, 985-991.
  • 8Lawrence A. H.. Ion mobility spectrometry/mass spectrometry of some prescription and illicit drugs [J], Anal. Chem., 1986, 58(6):1269-1272.
  • 9Karasek F. W., Hill H.H. Jr., Kim S.H.. Plasma chromatography of heroin and cocaine with mass-identified mobility spectra [J]. J. Chromatogr., 1976,117(2): 327-336.
  • 10Ewing R. G., Atkinson D. A., Eiceman G.A,,Ewing G.J..A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds [J].Talanta, 2001,54:515-529.

引证文献3

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部