期刊文献+

铒-钇铝石榴石激光乳化白内障吸除术的初步临床观察 被引量:4

原文传递
导出
出处 《中华眼科杂志》 CAS CSCD 北大核心 2004年第5期346-346,共1页 Chinese Journal of Ophthalmology
  • 相关文献

参考文献6

  • 1Fine IH,Packer M,Hoffman RS.New phacoemulsification technologies.J Cataract Refract Surg,2002,28:1054-1060.
  • 2Emery JM,Litte JH.Phacoemulsification and aspiration of cataracts.St.Louis:Mosby,1979.46-47.
  • 3Neubaur CC,Stevens-G Jr.Erbium:YAG laser cataract removal: role of fiber-optic delivery system.J Cataract Refract Surg,1999,25: 514-520.
  • 4Gimbel HV,da Reitz Pereira C.Advances in phacoemulsification equipment.Curr Opin Ophthalmol,2002,13:30-32.
  • 5Brazitikos P,D'Amico DJ,Bochow TW,et al.Experimental ocular surgery with a high-repetition-rate erbium:YAG laser.Invest Ophthalmol Vis Sci,1998,39:1667-1675.
  • 6何守志.白内障手术的新世纪展望[J].中华眼科杂志,2002,38(5):257-259. 被引量:32

共引文献31

同被引文献72

  • 1Drews RC. Five year study of astigmatic stability after cataract surgery with intraocular lens implantation : comparison of wound sizes [J]. J Cataract Refract Surg,2000,26:250-253.
  • 2Oshika T,Sugita G,Tanabe T,et al. Regular and irregular astigmatism after superior versus temporal scleval incision cataract surgery [ J ]. Ophthalmology, 2000,107 : 2049-20:53.
  • 3G. Panzardi. The use of thermography for temperature analysis during phaco-emulsification [ M ]//Lucio Buratto, Liliana Werner, Maurizio Zanini, et al. 2nd ed phaco-emulsification : Principles and Techniques, 2003 : 255-259.
  • 4Badoza D, Fernandez Mendy J, Ganly M. Phacoemulsification using the burst mode[J].J Cataract Refract Surg,2003 ,29 :1101-1105.
  • 5Tsuneoka Hz,Tsuneoka H, Shiba T, et al. Wound temperature during uhrasmall incision phacoemulsification [ J ]. Nippon Ganka Gakkai Zasshi ,2001,105:237-243.
  • 6Tsuneoka H, Shiha T, Takahashi Y, Ultrasonic phacoemulsitfication using a 1.4mm incision, clinical results [ J ]. J Cataract Refract Surg, 2002,28:81-86.
  • 7Domenfeld ED,Olson KJ,Solomon R,et al. Efficacy and wound-temperature gradient of whitestar phacoemulsification through a 1.2mm inoision[J]. J Cataract Refract Surg,2003,29 : 1097-1100.
  • 8Fine Ill,Packer M, Hoffman RS. New phacoemulsification technologies[ J ]. J Cataract Refract Surg,2002,28 : 1051-1060.
  • 9Gimbel HV,Sofinski S J, Kurteeva K,et al. Advan Tec legacy system and the NeosoniX handpiece [ J ]. Curr opin Ophthalmol, 2003,14 : 31-34.
  • 10Jiraskova N, Rozsival P. Phacoemulsification parameters Series 20000 legacy Versus legacy with Advan Tec software and NeosoniX handpiece[ J]. J cataract Refract Surg,2004,30:151-155.

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部