期刊文献+

TDLAS技术中谐波信号的理论推导与实验研究 被引量:5

Theoretical Derivation and Experimental Research of Harmonic Signals Based on TDLAS
下载PDF
导出
摘要 本文对可调谐二极管激光吸收光谱技术中的激光瞬时光强进行了数值模拟和物理实验验证,确定了波长调制法中激光瞬时光强的准确表达式,并由此推导出全新的谐波信号通项表达式,分析了被检信号与参考信号间的相位差对谐波信号的影响。在实验室条件下利用CO2分子位于6527.64 cm–1的吸收谱线进行了测量实验。测量结果表明,激光瞬时光强的调制幅度在扫描过程中固定,不随扫描平均光强而变化;被检信号与参考信号间的相位差会对谐波信号的幅值和相位产生影响,在气体浓度和温度测量中不可忽略。 In this paper, we derived the expression for the instantaneous intensity based on numerical simulation and practical experiments in tunable diode laser absorption spectroscopy, and determined the new expression of the harmonic signals in wavelength modulation spectroscopy, then we analyzed the influence to the harmonic signals caused by the phase shifts between the detected and reference signals. The transition of CO2 at 6527.64 cm–1 was selected for the practical experiments, and the experimental results indicated that, the amplitude of laser intensity modulation was invariant during the scanning process, which did not change with the average scanning laser intensity. What’s more, the amplitude and phase of the harmonic signals were influenced by the phase shifts between the detected and reference signals, which cannot be ignored in gas concentration and temperature measurements.
出处 《应用物理》 2012年第3期92-97,共6页 Applied Physics
基金 本课题由国家自然科学基金(51176085) 中国博士后科学基金(51176085)资助。
  • 相关文献

参考文献3

二级参考文献19

  • 1阚瑞峰,刘文清,张玉钧,刘建国,董凤忠,王敏,高山虎,陈军,王晓梅.可调谐二极管激光吸收光谱法监测环境空气中甲烷的浓度变化[J].中国激光,2005,32(9):1217-1220. 被引量:32
  • 2顾海涛,陈人,叶华俊,曾宏晔,王健.基于DLAS技术的现场在线气体浓度分析仪[J].仪器仪表学报,2005,26(11):1123-1126. 被引量:23
  • 3D. D. Nelson, J. H. Shorter, J. B. McManus et al.. Sub-part-perbillion detection of nitric oxide in air using a thermoelectrically cooled mid infrared quant urn cascade laser spectrometer [ J ]. Appl. Phys.(B), 2002, 75(3) : 343-350.
  • 4P. Werle, R. Mücke, F. D. Amato et al.. Near-infrared trace-gas sensors based on room-temperature diode lasers[J]. Appl. Phys.(B), 1998, 67(3): 307-315.
  • 5A. Nadezhdinskii, A. Berezin, S. Chernin et al.. High sensitivity methane analyzer based on tuned near infrared diode laser [J].Spectrochimica Acta Part A, 1999, 55(10) :2083-2089.
  • 6F. D. Amato, P. Mazzinghi, F. Castagnoli. Methane analyzer based on TDL's for measurements in the lower stratosphere: design and laboratory tests[J]. Appl. Phys. (B), 2002, 75(2): 195-202.
  • 7J. Reid, D. Labrie. Second-harmonic detection with tunable diode lasers-comparison of experiment and theory[J]. Appl. Phys. (B),1981, 26(2): 203-210.
  • 8Culshaw B,Stewart G,Dong F,et al.Fibre optic techniques for remote spectroscopic methane detection-from concept to system realization[J].Sensors and Actuators,1998,B51:25-37.
  • 9Werle P.A review of recent advances in semiconductor laser based gas monitors[J].Spectrochimica Acta,1998,A54:197-236.
  • 10Barrass S,Gérard Y,Holdsworth R J,et al.Near-infrared tunable diode laser spectrometer for the remote sensing of vehicle emissions[J].Spectrochimica Acta,2004,A60:3353-3360.

共引文献108

同被引文献59

引证文献5

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部