期刊文献+

Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header 被引量:2

Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header
下载PDF
导出
摘要 The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51. The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51.
出处 《Engineering(科研)》 2013年第1期66-68,共3页 工程(英文)(1947-3931)
关键词 SUPERHEATER OUTLET HEADER FINITE ELEMENT Method Stress CONCENTRATION Superheater Outlet header Finite Element Method Stress Concentration