Evaluation of HemogloBind<sup>TM</sup>treatment for preparation of samples for cholinesterase analysis

Evaluation of HemogloBind<sup>TM</sup>treatment for preparation of samples for cholinesterase analysis
下载PDF
导出
摘要 Acetylcholine is an essential neurotransmitter found throughout the nervous system. Its action on postsynaptic receptors is regulated through hydrolysis by various carboxylesterases, especially cholinesterases (ChEs). The acute toxicity of organophosphate (OP) compounds is directly linked to their action as inhibitors of ChE. One widely used assay for evaluating ChE activity is a spectrophotometric method developed by Ellman et al. When the enzyme source is from tissues or, in particular, blood, hemoglobin displays a spectrophotometric peak at the same wave-length used to analyze cholinergic activity. This creates a substantial background that interferes with the Ellman’s assay and must be overcome in order to accurately monitor cholinesterase activity. Herein, we directly compare blood processing methods: classical method (1.67 ± 0.30 U/mL) and HemogloBindTM treatment (1.51 ± 0.17 U/mL), and clearly demonstrate that pretreatment of blood samples with HemoglobindTM is both a sufficient and rapid sample preparation method for the assessment of ChE activity using the Ellman’s method. Acetylcholine is an essential neurotransmitter found throughout the nervous system. Its action on postsynaptic receptors is regulated through hydrolysis by various carboxylesterases, especially cholinesterases (ChEs). The acute toxicity of organophosphate (OP) compounds is directly linked to their action as inhibitors of ChE. One widely used assay for evaluating ChE activity is a spectrophotometric method developed by Ellman et al. When the enzyme source is from tissues or, in particular, blood, hemoglobin displays a spectrophotometric peak at the same wave-length used to analyze cholinergic activity. This creates a substantial background that interferes with the Ellman’s assay and must be overcome in order to accurately monitor cholinesterase activity. Herein, we directly compare blood processing methods: classical method (1.67 ± 0.30 U/mL) and HemogloBindTM treatment (1.51 ± 0.17 U/mL), and clearly demonstrate that pretreatment of blood samples with HemoglobindTM is both a sufficient and rapid sample preparation method for the assessment of ChE activity using the Ellman’s method.
出处 《Advances in Bioscience and Biotechnology》 2013年第12期1020-1023,共4页 生命科学与技术进展(英文)
关键词 ACETYLCHOLINESTERASE CHOLINESTERASE HemogloBindTM SAMPLE PREPARATION HEMOGLOBIN Acetylcholinesterase Cholinesterase HemogloBindTM Sample Preparation Hemoglobin
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部