Comparative Alpha Tracks Counting Using an Optical Microscope and a Spark Counter

Comparative Alpha Tracks Counting Using an Optical Microscope and a Spark Counter
下载PDF
导出
摘要 In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements. In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements.
作者 Dabo S. I. Agba Ponaho Kezo Issa Konaté Dabo S. I. Agba;Ponaho Kezo;Issa Konaté(Laboratory of Fundamental and Applied Physics, University Nangui Abrogoua, Abidjan, Cote d’Ivoire;Laboratory of Environmental Science and Technology, University Jean Lorougnon Guede, Daloa, Cote d’Ivoire;Nuclear Physics and Radiation Protection Team, Laboratory of Matter Sciences, Environment and Solar Energy, University Félix Houphou&#235,t Boigny, Abidjan, Cote d’Ivoire)
出处 《Detection》 2023年第2期7-18,共12页 检测(英文)
关键词 LR 115 Detector Optical Microscope Spark Counter Alpha Track Density Calibration Factor Radon Concentration LR 115 Detector Optical Microscope Spark Counter Alpha Track Density Calibration Factor Radon Concentration
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部