A simple, rapid and accurate ion-exclusion chromatographic method coupled with a UV detector for the determination of uric acid in human urine samples has been developed. The separation was carried out on an ion-exclu...A simple, rapid and accurate ion-exclusion chromatographic method coupled with a UV detector for the determination of uric acid in human urine samples has been developed. The separation was carried out on an ion-exclusion column using only pure water as mobile phase. The detection wavelength was 254 nm and urine sample was injected directly without any pretreatment. Furthermore, the retention behavior of uric acid on the ion-exclusion column was researched when pure water and 1 mmol·L-1 HCI were used as mobile phase, respectively. The stability of uric acid was also further investigated within 28 days, In this method, the linear range of the calibration curve for uric acid was 0.25--100 mg·L-1, and the detection limit calculated at S/N=3 was 0.02mg·L-1 The proposed ion-exclusion chromatographic method has been used for the determination of uric acid in human urine.展开更多
An ion-pair reversed-phase high-performance liquid chromatographic method, using tetrabutylammonium bromide (TBAB) as ion-pair reagent, has been developed for the analysis of cyanuric acid (CA) in milk powder and ...An ion-pair reversed-phase high-performance liquid chromatographic method, using tetrabutylammonium bromide (TBAB) as ion-pair reagent, has been developed for the analysis of cyanuric acid (CA) in milk powder and swimming pool water. It was found that the effect of the concentrations of ion-pair reagent on the retention of cyanuric acid was different for standard solution and different real samples. The separation was carried out on a reversed-phase C18 column with 85 : 15 (V/V) water-acetonitrile (ACN) containing different concentration of TBAB as mobile phase for different samples. The linear range of the calibration curve for CA was 0.1-100 mg·L^-1 The detection limits calculated at S/N=3 was 0.11 mg-L^-1 for the analysis of milk powder and 0.31 mg·L^-1 for the analysis of swimming pool water, respectively. The method was successfully applied to the analysis of CA in milk powder and swimming pool water.展开更多
文摘A simple, rapid and accurate ion-exclusion chromatographic method coupled with a UV detector for the determination of uric acid in human urine samples has been developed. The separation was carried out on an ion-exclusion column using only pure water as mobile phase. The detection wavelength was 254 nm and urine sample was injected directly without any pretreatment. Furthermore, the retention behavior of uric acid on the ion-exclusion column was researched when pure water and 1 mmol·L-1 HCI were used as mobile phase, respectively. The stability of uric acid was also further investigated within 28 days, In this method, the linear range of the calibration curve for uric acid was 0.25--100 mg·L-1, and the detection limit calculated at S/N=3 was 0.02mg·L-1 The proposed ion-exclusion chromatographic method has been used for the determination of uric acid in human urine.
文摘An ion-pair reversed-phase high-performance liquid chromatographic method, using tetrabutylammonium bromide (TBAB) as ion-pair reagent, has been developed for the analysis of cyanuric acid (CA) in milk powder and swimming pool water. It was found that the effect of the concentrations of ion-pair reagent on the retention of cyanuric acid was different for standard solution and different real samples. The separation was carried out on a reversed-phase C18 column with 85 : 15 (V/V) water-acetonitrile (ACN) containing different concentration of TBAB as mobile phase for different samples. The linear range of the calibration curve for CA was 0.1-100 mg·L^-1 The detection limits calculated at S/N=3 was 0.11 mg-L^-1 for the analysis of milk powder and 0.31 mg·L^-1 for the analysis of swimming pool water, respectively. The method was successfully applied to the analysis of CA in milk powder and swimming pool water.