We focus on the Mach–Zehnder interferometer(MZI) with the input of a coherent beam and one of the bright entangled twin beams with an external power reference beam employed for measurement. The results show that the ...We focus on the Mach–Zehnder interferometer(MZI) with the input of a coherent beam and one of the bright entangled twin beams with an external power reference beam employed for measurement. The results show that the phase sensitivity can reach sub-Heisenberg limit and approach quantum Cramer–Rao bound by changing the squeezing parameters and the photon number of the coherent beam, under the phase-matching condition. The absence of the external power reference beam will degrade the performance of the phase sensitivity. Meanwhile, this scheme shows good robustness against the losses of the photon detectors. We present a detailed discussion about the phase sensitivities when the inputs are two coherent beams, or a coherent beam plus a single-mode squeezed vacuum beam based on the MZI. This scenario can be applied in the field of phase precision measurements and other optical sensors.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant Nos.12104190,12104189,and 12204312)the Natural Science Foundation of Jiangsu Province (Grant No.BK20210874)+2 种基金the Jiangsu Provincial Key Research and Development Program (Grant No.BE2022143)the Jiangxi Provincial Natural Science Foundation (Grant Nos.20224BAB211014 and 20232BAB201042)the General Project of Natural Science Research in Colleges and Universities of Jiangsu Province (Grant No.20KJB140008)。
文摘We focus on the Mach–Zehnder interferometer(MZI) with the input of a coherent beam and one of the bright entangled twin beams with an external power reference beam employed for measurement. The results show that the phase sensitivity can reach sub-Heisenberg limit and approach quantum Cramer–Rao bound by changing the squeezing parameters and the photon number of the coherent beam, under the phase-matching condition. The absence of the external power reference beam will degrade the performance of the phase sensitivity. Meanwhile, this scheme shows good robustness against the losses of the photon detectors. We present a detailed discussion about the phase sensitivities when the inputs are two coherent beams, or a coherent beam plus a single-mode squeezed vacuum beam based on the MZI. This scenario can be applied in the field of phase precision measurements and other optical sensors.