Numerical investigation was performed to examine the effect of rear barrier pillar on stress distribution around a longwall face. Salamon theoretical formula was used to calculate the parameters of the caving zone, wh...Numerical investigation was performed to examine the effect of rear barrier pillar on stress distribution around a longwall face. Salamon theoretical formula was used to calculate the parameters of the caving zone, which was later assigned to double yield constitutive model in FLAC3 D. Numerical results demonstrate that high stress concentration zone exists above the region where the second open-off cut intersects with the rear barrier pillar due to stress transfer and plastic zone expansion. It is also found that the maximum vertical stresses with varied distance to the seam floor are all within the projective plane of the rear barrier pillar and their positions concentrate on the barrier pillar adjacent to the connection corner of the second open-off cut. In addition, position of the maximum vertical stresses abruptly transfer from the connection corner adjacent to former panel to that adjacent to current panel along the panel direction.展开更多
基金Projects(52179118,42077240,52104101) supported by the National Natural Science Foundation of ChinaProject(KJQN201900727) supported by the Scientific and Technological Research Program of Chongqing Municipal Education Commission,China。
基金Projects(5147420851304208)supported by the National Natural Science Foundation of China+3 种基金Project supported by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)ChinaProject(SKLCRSM12X01)supported by the State Key Laboratory of Coal Resources and Mine SafetyChina University of Mining and Technology
文摘Numerical investigation was performed to examine the effect of rear barrier pillar on stress distribution around a longwall face. Salamon theoretical formula was used to calculate the parameters of the caving zone, which was later assigned to double yield constitutive model in FLAC3 D. Numerical results demonstrate that high stress concentration zone exists above the region where the second open-off cut intersects with the rear barrier pillar due to stress transfer and plastic zone expansion. It is also found that the maximum vertical stresses with varied distance to the seam floor are all within the projective plane of the rear barrier pillar and their positions concentrate on the barrier pillar adjacent to the connection corner of the second open-off cut. In addition, position of the maximum vertical stresses abruptly transfer from the connection corner adjacent to former panel to that adjacent to current panel along the panel direction.