Neutrinos from core-collapse supernovae are essential for understanding neutrino physics and stellar evolution.Dual-phase xenon dark matter detectors can be used to track explosions of galactic supernovae by detecting...Neutrinos from core-collapse supernovae are essential for understanding neutrino physics and stellar evolution.Dual-phase xenon dark matter detectors can be used to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings.In this study,a variation of progenitor masses and explosion models are assumed to predict neutrino fluxes and spectra,which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-s duration with negligible backgrounds at PandaX-4T.Two specialized triggering alarms for monitoring supernova burst neutrinos are built.The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated.These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future,which will provide supernova early warnings for the astronomical community.展开更多
Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment,which is a multi-tonne dark matter direct search experiment.The accuracy of sign...Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment,which is a multi-tonne dark matter direct search experiment.The accuracy of signal reconstruction is influenced by various detector artifacts,including noise,dark count of photomultiplier,photoionization of impurities in the detector,and other relevant considerations.In this study,we presented a detailed description of a semi-data-driven approach designed to simulate a signal waveform.This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T.By comparing critical variables that relate to the temporal shape and hit pattern of the signals,we found good agreement between the simulation and data.展开更多
The proton-proton(pp)fusion chain dominates the neutrino production in the Sun.The uncertainty of the predicted pp neutrino flux is at the sub-percent level,whereas that of the best measurement is O(10%).In this study...The proton-proton(pp)fusion chain dominates the neutrino production in the Sun.The uncertainty of the predicted pp neutrino flux is at the sub-percent level,whereas that of the best measurement is O(10%).In this study,for the first time,we measure solar pp neutrinos in the electron recoil energy range from 24 to 144 keV using the PandaX-4T commissioning data with 0.63 tonne×year exposure.The pp neutrino flux is determined as(8.0±3.9(stat)±10.0(syst))×1010 s^(-1)cm^(-2),which is consistent with the Standard Solar Model and existing measurements,corresponding to an upper flux limit of 23.3×10^(10)s^(-1)cm^(-2)at 90%C.L..展开更多
The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level ne...The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.展开更多
基金the National Natural Science Foundation of China(12090060,12090063,12105052,12005131,11905128,11925502)the Office of Science and Technology,Shanghai Municipal Government,China(22JC1410100)。
文摘Neutrinos from core-collapse supernovae are essential for understanding neutrino physics and stellar evolution.Dual-phase xenon dark matter detectors can be used to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings.In this study,a variation of progenitor masses and explosion models are assumed to predict neutrino fluxes and spectra,which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-s duration with negligible backgrounds at PandaX-4T.Two specialized triggering alarms for monitoring supernova burst neutrinos are built.The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated.These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future,which will provide supernova early warnings for the astronomical community.
基金supported in part by the National Science Foundation of China(12090060,12090061)Ministry of Science and Technology of China(2023YFA1606200)+1 种基金Office of Science and Technology,Shanghai Municipal Government(22JC1410100)the Double First Class Plan of the Shanghai Jiao Tong University and Guangzhou Municipal Science and Technology Project(202201010991)。
文摘Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment,which is a multi-tonne dark matter direct search experiment.The accuracy of signal reconstruction is influenced by various detector artifacts,including noise,dark count of photomultiplier,photoionization of impurities in the detector,and other relevant considerations.In this study,we presented a detailed description of a semi-data-driven approach designed to simulate a signal waveform.This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T.By comparing critical variables that relate to the temporal shape and hit pattern of the signals,we found good agreement between the simulation and data.
基金supported in part by the grants from the National Science Foundation of China(12090060,12090063,12105052,12005131,11905128,11925502)the Office of Science and Technology,Shanghai Municipal Government(22JC1410100)+6 种基金the National Science Foundation of Sichuan ProvinceChina(2024NSFSC1371)the support from the Double First Class Plan of Shanghai Jiao Tong Universitythe sponsorship from the Chinese Academy of Sciences Center for Excellence in Particle Physics(CCEPP)Hongwen Foundation in Hong KongTencentNew Cornerstone Science Foundation in China。
文摘The proton-proton(pp)fusion chain dominates the neutrino production in the Sun.The uncertainty of the predicted pp neutrino flux is at the sub-percent level,whereas that of the best measurement is O(10%).In this study,for the first time,we measure solar pp neutrinos in the electron recoil energy range from 24 to 144 keV using the PandaX-4T commissioning data with 0.63 tonne×year exposure.The pp neutrino flux is determined as(8.0±3.9(stat)±10.0(syst))×1010 s^(-1)cm^(-2),which is consistent with the Standard Solar Model and existing measurements,corresponding to an upper flux limit of 23.3×10^(10)s^(-1)cm^(-2)at 90%C.L..
基金Supported by National Science Foundation of China(11055003,11175117)Science and Technology Commission of Shanghai Municipality(11PJ1405300)Ministry of Science and Technology of China(2010CB833005)
文摘The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.