期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Accuracy of Trans-Cerebellar Diameter and Placental Thickness in Third Trimesteric Pregnant Women for Calculation of Gestational Age: A Cross Sectional Study
1
作者 Alaa Sayed Hassanin Hassan Tawfik Khairy +1 位作者 aya tullah abd elfatah elshaer Sarah Safwat 《Open Journal of Obstetrics and Gynecology》 CAS 2023年第2期303-314,共12页
Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnanc... Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnancy. Objective: The aim of the study was to assess whether the trans-cerebellar diameter, placental thickness or combining both of them is more accurate for assessment of gestational age in the 3<sup>rd</sup> trimester of pregnancy. Patients and Methods: This is a cross sectional study conducted at outpatient Clinic and Obstetric ward, Ain Shams University Maternity Hospital, over a period of six months from March 2019 to September 2019. One hundred pregnant women were recruited according to inclusion criteria either from outpatient clinic or were admitted in obstetric ward Ain Shams Maternity Hospital to find out the most accurate fetal biometric measurement in the third trimester either trans-cerebellar diameter placental thickness or both compared to reliable LMP (last menstrual period) dates confirmed by crown rump length (CRL) in the first trimester. Results: Trans-cerebellar diameter mean ± SD was 46.0 ± 3.5 with range 38.2 - 51.7. The mean of placental thickness was 39.6 ± 7.1 with range 22.8 - 54.3. Placental thickness had highest determination (0.813) for last menstrual period followed by trans-cerebellar diameter (0.802). Combining trans-cerebellar diameter and placental thickness increased determination (0.902) for last menstrual period. Conclusion: Combined use of trans-cerebellar diameter and placental thickness in the third trimester of pregnancy is a reliable indicator for gestational age in women whose last menstrual period is unreliable or unknown, but placental thickness had higher accuracy than trans-cerebellar diameter. 展开更多
关键词 Accuracy of Trans-Cerebellar Diameter Placental Thickness Third Tri-mesteric Pregnant Women Gestational Age
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部