期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Quantification of sibutramine and its two metabolites in human plasma by LC-ESI-MS/MS and its application in a bioequivalence study 被引量:6
1
作者 Venkata Suresh Ponnuru b.r.challa RamaRao Nadendla 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第4期249-257,共9页
Obesity can be considered as a chronic illness of epidemic proportion and its incidents have increased exponentially in recent years.The use of anti-obesity drugs such as sibutramine is somewhat helpful.There is a nee... Obesity can be considered as a chronic illness of epidemic proportion and its incidents have increased exponentially in recent years.The use of anti-obesity drugs such as sibutramine is somewhat helpful.There is a need to quantify such drugs in biological samples,which is generally quite difficult.In this report,we developed and validated a simple,sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of sibutramine (SB) and its two metabolites N-des methyl sibutramine (DSB) and N-di desmethyl sibutramine (DDSB) in human plasma.Zorbax SBC18 (4.6 mm × 75 mm,3.5 μm,80 (A)) analytical column and 5 mM ammonium formate:acetonitrile (10∶90,v/v) mobile phase were used for chromatographic separation of SB,DSB and DDSB.Multiple reaction monitoring (MRM) in the positive mode was used to detect SB,DSB and DDSB at m/z 280.3/124.9,266.3/125.3 and 252.2/124.9,respectively.Liquid liquid extraction was used for the extraction of analytes and internal standard from human plasma.This method was validated over a linear concentration range of 10.0-10,000.0 pg/mL for SB,DSB and DDSB with correlation coefficients (r) of ≥0.9997.The drug and the two metabolites were stable in plasma samples.The validated method was successfully applied in a bioequivalence and pharmacokinetic study with human volunteers under fasting condition. 展开更多
关键词 LC–ESI-MS/MS SIBUTRAMINE Human plasma BIOEQUIVALENCE Pharmacokinetic study
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:2
2
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 b.r.challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 High performance liquid chromatography Mass spectrometry RASAGILINE Liquid-liquid extraction
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部