Background: Individualized corneal refractive surgery requires an understanding of the basis of higher-order aberrations before surgery. To investigate the characteristics and distribution of anterior surface wavefron...Background: Individualized corneal refractive surgery requires an understanding of the basis of higher-order aberrations before surgery. To investigate the characteristics and distribution of anterior surface wavefront aberrations in patients suitable for corneal refractive surgery. Methods: A total of 121 myopic patients (121 eyes, 18 - 45 years old) who underwent corneal refractive surgery were recruited from January to May 2016 at Affiliated Hospital, Yanbian University. Patients were randomly selected by the Pentacam anterior segment analysis system with a spherical equivalent (SE) of -0.25 to -10.00 D. The corneal anterior aberrations (total higher-order aberration;spherical aberration;Coma;Trefoil) and Q and K values were detected, and a correlation analysis of the relevant parameters was carried out. Results: The root-mean-square (RMS) of the third to sixth order aberrations of the corneal anterior wavefront aberrations at a 6 mm analysis diameter showed a decreasing trend in patients suitable for the corneal refractive surgery, and the RMS of the third order aberrations accounted for 62.92% of the total HOAs. The coma ratio (coma/total cornea higher-order aberrations) was increased with the increasing diopters, while the spherical aberration ratio (spherical aberration/total cornea higher-order aberrations) was not changed. In addition, the spherical aberration was 0.203 ± 0.082 μm (range: 0.061 to 0.503 μm), and the Q30 was -0.19 ± 0.03 (range: -0.58 to 0.31). There were significant differences in the coma aberrations of preoperative corneal anterior surface (3, 1) between the low, middle and high myopia groups (P = 0.013). The spherical equivalent was positively correlated with the corneal coma of the anterior corneal surfaces (R =?-0.241, P = 0.009), and the Q value was positively correlated with the total higher-order aberrations (R = 0.326, P Conclusions: Individual wavefront aberrations on the anterior surfaces of the cornea are comparatively different, and the Zernike coefficients are related to the degree of myopia. Spherical aberrations are the most overriding aberrations of the cornea.展开更多
The acute onset of the vision loss by optic never injury following orbital wall reconstruction, has been reported in 0.5% - 5.0% of the cases. Visual impairment can be recovered within an early period after injury. De...The acute onset of the vision loss by optic never injury following orbital wall reconstruction, has been reported in 0.5% - 5.0% of the cases. Visual impairment can be recovered within an early period after injury. Delayed visual recovery from optic nerve injury during a procedure of orbital wall reconstruction has not been reported. We report a case of delayed recovery from optic nerve injury which occurred following orbital wall reconstruction. A 78-year-old man underwent orbital wall reconstruction for medial wall fracture and resulting enophthalmos in the right eye, one week after a traffic accident. Immediate after surgery, postoperative visual acuity in the right eye decreased to light perception, and relative afferent pupillary defect (RAPD) was detected. In spite of mega-dose steroid treatment, the visual acuity did not improve. However, 8 months after surgery, visual acuity began to recover to 0.1, and the degree of RAPD decreased. Twelve months after surgery, visual acuity in the right eye was 0.4, and pupillary light reflex was normal. Our report suggests that patients with optic neuropathy by surgery or trauma require long-term follow-up, regardless of early response to mega-dose steroid treatment.展开更多
Al-containing MAX phase ceramic has demonstrated great potential in the field of high-performance low-voltage electrical contact material.Elucidating the anti-arc erosion mechanism of the MAX phase is crucial for furt...Al-containing MAX phase ceramic has demonstrated great potential in the field of high-performance low-voltage electrical contact material.Elucidating the anti-arc erosion mechanism of the MAX phase is crucial for further improving performance,but it is not well-understood.In this study,Ag/Ti_(3)AlC_(2) electrical contact material was synthesized by powder metallurgy and examined by nanoindentation techniques such as constant loading rate indentation,creep testing,and continuous stiffness measurements.Our results indicated a gradual degradation in the nano-mechanical properties of the Ti_(3)AlC_(2) reinforcing phase with increasing arc erosion times,although the rate of this degradation appeared to decelerate over arc erosion times.Specifically,continuous stiffness measurements highlighted the uneven mechanical properties within Ti_(3)AlC_(2),attributing this heterogeneity to the phase’s decomposition.During the early(1-100 times)and intermediate(100-1000 times)stages of arc erosion,the decline in the nano-mechanical properties of Ti_(3)AlC_(2) was primarily ascribed to the decomposition of Ti_(3)AlC_(2) and limited surface oxidation.During the later stage of arc erosion(1000-6200 times),the inner region of Ti_(3)AlC_(2) also sustained arc damage,but a thick oxide layer formed on its surface,enhancing the mechanical properties and overall arc erosion resistance of the Ag/Ti_(3)AlC_(2).展开更多
文摘Background: Individualized corneal refractive surgery requires an understanding of the basis of higher-order aberrations before surgery. To investigate the characteristics and distribution of anterior surface wavefront aberrations in patients suitable for corneal refractive surgery. Methods: A total of 121 myopic patients (121 eyes, 18 - 45 years old) who underwent corneal refractive surgery were recruited from January to May 2016 at Affiliated Hospital, Yanbian University. Patients were randomly selected by the Pentacam anterior segment analysis system with a spherical equivalent (SE) of -0.25 to -10.00 D. The corneal anterior aberrations (total higher-order aberration;spherical aberration;Coma;Trefoil) and Q and K values were detected, and a correlation analysis of the relevant parameters was carried out. Results: The root-mean-square (RMS) of the third to sixth order aberrations of the corneal anterior wavefront aberrations at a 6 mm analysis diameter showed a decreasing trend in patients suitable for the corneal refractive surgery, and the RMS of the third order aberrations accounted for 62.92% of the total HOAs. The coma ratio (coma/total cornea higher-order aberrations) was increased with the increasing diopters, while the spherical aberration ratio (spherical aberration/total cornea higher-order aberrations) was not changed. In addition, the spherical aberration was 0.203 ± 0.082 μm (range: 0.061 to 0.503 μm), and the Q30 was -0.19 ± 0.03 (range: -0.58 to 0.31). There were significant differences in the coma aberrations of preoperative corneal anterior surface (3, 1) between the low, middle and high myopia groups (P = 0.013). The spherical equivalent was positively correlated with the corneal coma of the anterior corneal surfaces (R =?-0.241, P = 0.009), and the Q value was positively correlated with the total higher-order aberrations (R = 0.326, P Conclusions: Individual wavefront aberrations on the anterior surfaces of the cornea are comparatively different, and the Zernike coefficients are related to the degree of myopia. Spherical aberrations are the most overriding aberrations of the cornea.
文摘The acute onset of the vision loss by optic never injury following orbital wall reconstruction, has been reported in 0.5% - 5.0% of the cases. Visual impairment can be recovered within an early period after injury. Delayed visual recovery from optic nerve injury during a procedure of orbital wall reconstruction has not been reported. We report a case of delayed recovery from optic nerve injury which occurred following orbital wall reconstruction. A 78-year-old man underwent orbital wall reconstruction for medial wall fracture and resulting enophthalmos in the right eye, one week after a traffic accident. Immediate after surgery, postoperative visual acuity in the right eye decreased to light perception, and relative afferent pupillary defect (RAPD) was detected. In spite of mega-dose steroid treatment, the visual acuity did not improve. However, 8 months after surgery, visual acuity began to recover to 0.1, and the degree of RAPD decreased. Twelve months after surgery, visual acuity in the right eye was 0.4, and pupillary light reflex was normal. Our report suggests that patients with optic neuropathy by surgery or trauma require long-term follow-up, regardless of early response to mega-dose steroid treatment.
基金supported by the National Natural Science Foundation of China(52101064,52171033)Jiangsu Planned Projects for Postdoctoral Research Funds(2020Z158)Natural Science Foundation of Jiangsu Province(BK20220627).
文摘Al-containing MAX phase ceramic has demonstrated great potential in the field of high-performance low-voltage electrical contact material.Elucidating the anti-arc erosion mechanism of the MAX phase is crucial for further improving performance,but it is not well-understood.In this study,Ag/Ti_(3)AlC_(2) electrical contact material was synthesized by powder metallurgy and examined by nanoindentation techniques such as constant loading rate indentation,creep testing,and continuous stiffness measurements.Our results indicated a gradual degradation in the nano-mechanical properties of the Ti_(3)AlC_(2) reinforcing phase with increasing arc erosion times,although the rate of this degradation appeared to decelerate over arc erosion times.Specifically,continuous stiffness measurements highlighted the uneven mechanical properties within Ti_(3)AlC_(2),attributing this heterogeneity to the phase’s decomposition.During the early(1-100 times)and intermediate(100-1000 times)stages of arc erosion,the decline in the nano-mechanical properties of Ti_(3)AlC_(2) was primarily ascribed to the decomposition of Ti_(3)AlC_(2) and limited surface oxidation.During the later stage of arc erosion(1000-6200 times),the inner region of Ti_(3)AlC_(2) also sustained arc damage,but a thick oxide layer formed on its surface,enhancing the mechanical properties and overall arc erosion resistance of the Ag/Ti_(3)AlC_(2).