A novel Bi2S3 microsphere was fabricated through one-pot urea-assisted solvothermal method.The synthesized Bi2S3 microsphere was characterized by X-ray diffraction(XRD),scanning electron microscopy(SEM),Fourier transf...A novel Bi2S3 microsphere was fabricated through one-pot urea-assisted solvothermal method.The synthesized Bi2S3 microsphere was characterized by X-ray diffraction(XRD),scanning electron microscopy(SEM),Fourier transformed infrared spectroscopy(FT-IR)and thermal gravimetric analysis and differential thermal analysis(DTA-TG).Subsequently,the photocatalytic performances of Bi2S3 microsphere were evaluated by photocatalytic degradation of methyl orange(MO)simulation solution under visible-light irradiation.The results show that,Bi2S3 microsphere could be used as a potential cost-efficient catalysis for eliminating of methyl orange from aqueous solutions,whose degradation rate could reach 91.07%within 180 min.Besides,a tentative photocatalytic reaction mechanism was discussed according to the energy band position.Therefore,this work indicated a simplistic approach for the fabrication of visible-light responsive Bi2S3 microsphere photocatalyst,which can be used as a valuable candidate in solar energy conversion and environment pollution treatment.展开更多
Objective: Ventilator associated pneumonia (VAP) has been shown to be associated with significant morbidity and mortality( Chastre and Fagon, 2002; klompas, 2007) among mechanically venti- lated patients in the i...Objective: Ventilator associated pneumonia (VAP) has been shown to be associated with significant morbidity and mortality( Chastre and Fagon, 2002; klompas, 2007) among mechanically venti- lated patients in the intensive care unit (ICU), with the incidence ranging from 9% to 27% ; crude mortality ranges from 25% to 50%.1-3 A meta-analysis of published studies was undertaken to combine information regarding the effect of subglottic secretion drainage (SSD) on the incidence of ventilated associated pneumonia in adult ICU patients. Methods: Reports of studies on SSD were identified by searching the PUBMED, EMBASE, and COCHRANCE LIBRARY databases (December 30, 2010). Randomized trials of SSD compared to usual care in adult mechanically ventilated ICU patients were included in this meta-analysis. Results: Ten RCTs with 2,314 patients were identified. SSD significantly reduced the incidence of VAP [ relative risk (RR) =0.52, 95% confidence interval (C/): 0.42-0.64, P〈0.000 01]. When SSD was compared with the control groups, the overall RR for ICU mortality was 1.00 (95% CI, 0.84-1.19) and for hospital mortality was 0.95 (95% CI, 0. 80-1.13). Overall, the subglottic drainage effect on the days of mechanical ventilation was -1.52 days (95% CI, -2.94 to -0.11) and on the ICU length of stay (LOS) was -0.81days (95% CI, -2.33 to -0.7). Conclusions: In this meta-analysis, when an endotracheal tube (ETT) with SSD was compared with an ETT without SSD, there was a highly significant reduction in the VAP rate of approxi- mately 50%. Time on mechanical ventilation (MV) and the ICU LOS may be reduced, but no reduction in ICU or hospital mortality has been observed in published trials,展开更多
基金Projects(21476269,21776319) supported by the National Natural Science Foundation of ChinaProject(2016TP1007) supported by Hunan Provincial Science and Technology Plan Project of China+2 种基金Project(2017J01569) supported by the Natural Science Foundation of Fujian Province,ChinaProject(201710533255) supported by National College Students’ Free Exploration Project of ChinaProject(2017zzts777) supported by Fundamental Research Funds for the Central Universities of Central South University,China
文摘A novel Bi2S3 microsphere was fabricated through one-pot urea-assisted solvothermal method.The synthesized Bi2S3 microsphere was characterized by X-ray diffraction(XRD),scanning electron microscopy(SEM),Fourier transformed infrared spectroscopy(FT-IR)and thermal gravimetric analysis and differential thermal analysis(DTA-TG).Subsequently,the photocatalytic performances of Bi2S3 microsphere were evaluated by photocatalytic degradation of methyl orange(MO)simulation solution under visible-light irradiation.The results show that,Bi2S3 microsphere could be used as a potential cost-efficient catalysis for eliminating of methyl orange from aqueous solutions,whose degradation rate could reach 91.07%within 180 min.Besides,a tentative photocatalytic reaction mechanism was discussed according to the energy band position.Therefore,this work indicated a simplistic approach for the fabrication of visible-light responsive Bi2S3 microsphere photocatalyst,which can be used as a valuable candidate in solar energy conversion and environment pollution treatment.
文摘Objective: Ventilator associated pneumonia (VAP) has been shown to be associated with significant morbidity and mortality( Chastre and Fagon, 2002; klompas, 2007) among mechanically venti- lated patients in the intensive care unit (ICU), with the incidence ranging from 9% to 27% ; crude mortality ranges from 25% to 50%.1-3 A meta-analysis of published studies was undertaken to combine information regarding the effect of subglottic secretion drainage (SSD) on the incidence of ventilated associated pneumonia in adult ICU patients. Methods: Reports of studies on SSD were identified by searching the PUBMED, EMBASE, and COCHRANCE LIBRARY databases (December 30, 2010). Randomized trials of SSD compared to usual care in adult mechanically ventilated ICU patients were included in this meta-analysis. Results: Ten RCTs with 2,314 patients were identified. SSD significantly reduced the incidence of VAP [ relative risk (RR) =0.52, 95% confidence interval (C/): 0.42-0.64, P〈0.000 01]. When SSD was compared with the control groups, the overall RR for ICU mortality was 1.00 (95% CI, 0.84-1.19) and for hospital mortality was 0.95 (95% CI, 0. 80-1.13). Overall, the subglottic drainage effect on the days of mechanical ventilation was -1.52 days (95% CI, -2.94 to -0.11) and on the ICU length of stay (LOS) was -0.81days (95% CI, -2.33 to -0.7). Conclusions: In this meta-analysis, when an endotracheal tube (ETT) with SSD was compared with an ETT without SSD, there was a highly significant reduction in the VAP rate of approxi- mately 50%. Time on mechanical ventilation (MV) and the ICU LOS may be reduced, but no reduction in ICU or hospital mortality has been observed in published trials,