Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero ...Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving.展开更多
To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building...To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building energy consumption,especially in tropical and subtropical areas.A proper way should be employed to reduce the cooling load of fresh air.Radiative sky cooling,which is the process that an object cools itself by emitting thermal radiation to outer space without any energy input,is a cost-effective and eco-friendly technology.In this work,a fresh air pre-cooling system using radiative sky cooling is proposed to reduce fresh air cooling load.The system,consisting of filters,a radiative air-cooling system,an air handling unit(AHU),fans,etc.,is installed on the rooftop of the modeled building.Six cities in low-latitude areas are selected and investigated.Results show that with the radiative air-cooling system installed,annual cooling energy consumption of the modeled building can be reduced by around 10%in most cities.For arid areas,e.g.,Abu Dhabi,the system has even better performance with 19.34%annual cooling energy saving.展开更多
A transparent radiative cooling(T-RC)film with low transmittance in solar spectra and selectively high emissivity in the atmospheric window(8-13𝜇m)is applied on roof glazing for building energy saving.To evalu...A transparent radiative cooling(T-RC)film with low transmittance in solar spectra and selectively high emissivity in the atmospheric window(8-13𝜇m)is applied on roof glazing for building energy saving.To evaluate the per-formance of the T-RC film,two identical model boxes(1.0 m×0.6 m×1.2 m,L×W×H)were constructed and the inside air temperatures were measured in August in Ningbo,China.Results show that the maximum temperature difference between the two model boxes with and without the T-RC film was 21.6℃during the experiment.A whole building model was built in EnergyPlus for the model box.With a good agreement achieved between the calculation results and the measured temperature data,the experimentally validated EnergyPlus model was then extended to an 815.1 m^(2)exhibition building with roof glazing to analyze the annual air conditioning(AC)energy consumption.The results show that by incorporating both the T-RC film’s cooling benefit in summer and heating penalty in winter,the annual AC energy consumption of the exhibition building can be reduced by 40.9-63.4%,varying with different climate conditions.展开更多
基金the support from National Natural Sci-ence Foundation of China(52276178)Natural Science Foundation of Jiangsu Province,China(BK20200373).
文摘Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving.
基金support from the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20200373).
文摘To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building energy consumption,especially in tropical and subtropical areas.A proper way should be employed to reduce the cooling load of fresh air.Radiative sky cooling,which is the process that an object cools itself by emitting thermal radiation to outer space without any energy input,is a cost-effective and eco-friendly technology.In this work,a fresh air pre-cooling system using radiative sky cooling is proposed to reduce fresh air cooling load.The system,consisting of filters,a radiative air-cooling system,an air handling unit(AHU),fans,etc.,is installed on the rooftop of the modeled building.Six cities in low-latitude areas are selected and investigated.Results show that with the radiative air-cooling system installed,annual cooling energy consumption of the modeled building can be reduced by around 10%in most cities.For arid areas,e.g.,Abu Dhabi,the system has even better performance with 19.34%annual cooling energy saving.
基金D.Z.acknowledges the support from“the Fundamental Re-search Funds for the Central Universities”under award number 2242020R10017.
文摘A transparent radiative cooling(T-RC)film with low transmittance in solar spectra and selectively high emissivity in the atmospheric window(8-13𝜇m)is applied on roof glazing for building energy saving.To evaluate the per-formance of the T-RC film,two identical model boxes(1.0 m×0.6 m×1.2 m,L×W×H)were constructed and the inside air temperatures were measured in August in Ningbo,China.Results show that the maximum temperature difference between the two model boxes with and without the T-RC film was 21.6℃during the experiment.A whole building model was built in EnergyPlus for the model box.With a good agreement achieved between the calculation results and the measured temperature data,the experimentally validated EnergyPlus model was then extended to an 815.1 m^(2)exhibition building with roof glazing to analyze the annual air conditioning(AC)energy consumption.The results show that by incorporating both the T-RC film’s cooling benefit in summer and heating penalty in winter,the annual AC energy consumption of the exhibition building can be reduced by 40.9-63.4%,varying with different climate conditions.