期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Prognostic value of decision criteria for emergency liver transplantation in patients with wild mushroom induced acute liver injury 被引量:1
1
作者 Youn-Jung Kim Hyung Joo Lee +5 位作者 Seung Mok Ryoo Shin Ahn Chang Hwan Sohn dong-woo seo Kyoung Soo Lim Won Young Kim 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2018年第3期210-213,共4页
Background: The reported mortality rate of mushroom-induced acute liver failure with conventionaltreatment is 1.4%–16.9%. Emergency liver transplantation may be indicated and can be the only curativetreatment option... Background: The reported mortality rate of mushroom-induced acute liver failure with conventionaltreatment is 1.4%–16.9%. Emergency liver transplantation may be indicated and can be the only curativetreatment option. This study aimed to assess the prognostic value of criteria for emergency livertransplantation in predicting 28-day mortality in patients with mushroom-induced acute liver injury.Methods: A retrospective cohort study was performed between January 2005 and December 2015. Alladult patients aged≥18 years admitted with mushroom intoxication at our emergency department wereevaluated. All patients with acute liver injury, defined as elevation of serum liver enzymes (〉5 timesthe upper limit of normal, ULN) or moderate coagulopathy (INR 〉 2.0) were included. The ability of the King’s College, Ganzert’s, and Escudié’s criteria to predict 28-day mortality was evaluated. 展开更多
关键词 Liver failure Mushroom poisoning Liver transplantation Clinical decision making
下载PDF
Experimental Study on the Mechanical Properties of FRP Bars by Hybridizing with Steel Wires 被引量:1
2
作者 Ji-Hyun Hwang dong-woo seo +1 位作者 Ki-Tae Park Young-Jun You 《Engineering(科研)》 2014年第7期365-373,共9页
Many studies on fiber reinforced polymer composite bars, as a substitute for reinforcing bars, have been conducted to solve corrosion of steel in reinforced concrete structures since 1960s’. However, FRP Bars have a ... Many studies on fiber reinforced polymer composite bars, as a substitute for reinforcing bars, have been conducted to solve corrosion of steel in reinforced concrete structures since 1960s’. However, FRP Bars have a lower elastic modulus than steel rebar as a structural component of concrete structures. Material properties with brittleness fracture and low elastic modulus can be improved by combining cheaper steel than carbon or aramid fibers. In this study, prototypes of FRP Bars with inserted steel wires (i.e., “FRP Hybrid Bars”) were developed and their tensile performance was compared depending on the proportion and diameter of steel. The FRP Hybrid Bars were made by dividing them into D13 and D16 according to the diameter and proportion of inserted wires: GFRPs were combined with wires having different diameters of 0.5 mm, 1.0 mm, and 2.0 mm in the proportion of 10%, 30%, 50%, and 70%, respectively. As a result of tensile tests, the elastic modulus of FRP Hybrid Bars were improved as 20% - 190% in comparison with the fully GFRP Bars. 展开更多
关键词 Fiber-Reinforced POLYMER (FRP) FRP Hybrid BAR TENSILE Test Steel WIRE
下载PDF
Enhancement in Elastic Modulus of GFRP Bars by Material Hybridization
3
作者 dong-woo seo Ki-Tae Park +1 位作者 Young-Jun You Hyeong-Yeol Kim 《Engineering(科研)》 2013年第11期865-869,共5页
Fiber reinforced polymer (FRP) reinforcing bars for concrete structure has been extensively investigated for last two decades and a number of FRP bars are commercially available. However, one of shortcomings of the ex... Fiber reinforced polymer (FRP) reinforcing bars for concrete structure has been extensively investigated for last two decades and a number of FRP bars are commercially available. However, one of shortcomings of the existing FRP bars is its low elastic modulus, if glass fibers are used (i.e., GFRP). The main objective of this study using the concept of material hybridization is to develop a viable hybrid FRP bar for concrete structures, especially for marine and port con- crete structures. The purposes of hybridization are to increase the elastic modulus of GFRP bar with acceptable tensile strength. Two types of hybrid GFRP bar were considered in the development: GFRP crust with steel core and GFRP bar with steel wires dispersed over the cross-section. Using E-glass fibers and unsaturated polyester resins, the hybrid GFRP bar samples of 13 mm in diameter were pultruded and tested for tensile properties. The effect of hybridization on tensile properties of GFRP bars was evaluated by comparing the results of tensile test with those of non-hybrid GFRP bars. The results of this study indicated that the elastic modulus of the hybrid GFRP bar was increased by up to 270 percent by the material hybridization. The results of the test and the future recommendations are summarized in this paper. To ensure long-term durability of the hybrid GFRP bars in waterfront structure applications, the individual and combined effects of environmental conditions on hybrid GFRP rebar itself as well as on the interface between rebar and concrete should be accessed. 展开更多
关键词 FRP Glass Fibers TENSILE Test Elastic MODULUS PULTRUSION MATERIAL HYBRIDIZATION Marine Structures
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部