The control effects of six kinds of reagents against rice sheath blight were compared in the test. The results showed that 24% thifluzamide SC 300 mL/hm2 and 20% Jinggangmycin ~ prochloraz WP 750 g/hm2 had good contro...The control effects of six kinds of reagents against rice sheath blight were compared in the test. The results showed that 24% thifluzamide SC 300 mL/hm2 and 20% Jinggangmycin ~ prochloraz WP 750 g/hm2 had good control effect against rice sheath blight, and their control effects after spraying for 7 and 14 d were 72.16%, 77.91% and 66.52%, 71.08%, respectively. The control effects of both reagents were significantly better than other test reagents and control re- agent Jinggangmycin, and they had no adverse effect on growth and development of rice. Considering from the aspects of control effect and economy, 20% Jinggang- mycin ~ prochloraz WP was suggested to be used to control rice sheath blight, its recommended dosage was 600 -750 g/hm2, and the reagent volume was 750kg with coarse spraying.展开更多
The Circular Electron Positron Collider(CEPC)is a large scientific project initiated and hosted by China,fostered through extensive collaboration with international partners.The complex comprises four accelerators:a 3...The Circular Electron Positron Collider(CEPC)is a large scientific project initiated and hosted by China,fostered through extensive collaboration with international partners.The complex comprises four accelerators:a 30 GeV Linac,a 1.1 GeV Damping Ring,a Booster capable of achieving energies up to 180 GeV,and a Collider operating at varying energy modes(Z,W,H,and tt).The Linac and Damping Ring are situated on the surface,while the subterranean Booster and Collider are housed in a 100 km circumference underground tunnel,strategically accommodating future expansion with provisions for a potential Super Proton Proton Collider(SPPC).The CEPC primarily serves as a Higgs factory.In its baseline design with synchrotron radiation(SR)power of 30 MW per beam,it can achieve a luminosity of 5×10^(34)cm^(-2)s^(-1)per interaction point(IP),resulting in an integrated luminosity of 13 ab^(-1)for two IPs over a decade,producing 2.6 million Higgs bosons.Increasing the SR power to 50 MW per beam expands the CEPC's capability to generate 4.3 million Higgs bosons,facilitating precise measurements of Higgs coupling at sub-percent levels,exceeding the precision expected from the HL-LHC by an order of magnitude.This Technical Design Report(TDR)follows the Preliminary Conceptual Design Report(Pre-CDR,2015)and the Conceptual Design Report(CDR,2018),comprehensively detailing the machine's layout,performance metrics,physical design and analysis,technical systems design,R&D and prototyping efforts,and associated civil engineering aspects.Additionally,it includes a cost estimate and a preliminary construction timeline,establishing a framework for forthcoming engineering design phase and site selection procedures.Construction is anticipated to begin around 2027-2028,pending government approval,with an estimated duration of 8 years.The commencement of experiments and data collection could potentially be initiated in the mid-2030s.展开更多
Measuring the topological charge(TC) of optical vortex beams by the edge-diffraction pattern of a single plate is proposed and demonstrated. The diffraction fringes can keep well discernible in a wide three-dimensiona...Measuring the topological charge(TC) of optical vortex beams by the edge-diffraction pattern of a single plate is proposed and demonstrated. The diffraction fringes can keep well discernible in a wide three-dimensional range in this method. The redundant fringes of the diffracted fork-shaped pattern in the near-field can determine the TC value, and the orientation of the fork tells the handedness of the vortex. The plate can be opaque or translucent, and the requirement of the translucent plate for TC measurement is analyzed. Measurement of TCs up to ±40 is experimentally demonstrated by subtracting the upper and lower fringe numbers with respect to the center of the light. The plate is easy to get, and this feasible measurement can bring great convenience and efficiency for researchers.展开更多
In this paper,a 2D angle amplifier based on peristrophic multiplexed volume Bragg gratings is designed and prepared,in which a calculation method is firstly proposed to optimize the number of channels to a minimum.The...In this paper,a 2D angle amplifier based on peristrophic multiplexed volume Bragg gratings is designed and prepared,in which a calculation method is firstly proposed to optimize the number of channels to a minimum.The induction of peristrophic multiplexing reduces the performance difference in one bulk of the grating,whereas there is no need to deliberately optimize the fabrication process.It is revealed that a discrete 2D angle deflection range of±30°is obtained and the relative diffraction efficiency of all the grating channels reaches more than 55%with a root-meansquare deviation of less than 3.4%in the same grating.The deviation of the Bragg incidence and exit angles from the expected values is less than 0.07°.It is believed that the proposed 2D angle amplifier has the potential to realize high-performance and large-angle beam steering in high-power laser beam scanning systems.展开更多
This work presents a brief introduction on three kinds of newly developed Nd^(3+)-doped laser glasses in Shanghai Institute of Optics and Fine Mechanics(SIOM), China. Two Nd^(3+)-doped phosphate glasses with lower the...This work presents a brief introduction on three kinds of newly developed Nd^(3+)-doped laser glasses in Shanghai Institute of Optics and Fine Mechanics(SIOM), China. Two Nd^(3+)-doped phosphate glasses with lower thermal expansion coefficient and thermal shock resistance 4 times higher than that of N31 glass are developed for laser processing.Nd:Silicate and Nd:Aluminate glasses with peak emission wavelength at 1061 and 1065 nm, effective emission bandwidth of 34 and 50 nm, respectively, are developed for Exawatt-class laser system application. Fluorophosphate glasses with low nonlinear refractive index(n_2=0.6–0.86) and long fluorescence lifetime(430–510 μs) are investigated for the purpose of decreasing B integral in high-power laser system. The properties of all these glasses are presented and compared with those of commercial neodymium laser glasses.展开更多
基金Supported by National Torch Plan Project(2010GH020365)Jurong Authorized Invention Patent Achievement Transformation Project of Jiangsu Province (ZL201003)
文摘The control effects of six kinds of reagents against rice sheath blight were compared in the test. The results showed that 24% thifluzamide SC 300 mL/hm2 and 20% Jinggangmycin ~ prochloraz WP 750 g/hm2 had good control effect against rice sheath blight, and their control effects after spraying for 7 and 14 d were 72.16%, 77.91% and 66.52%, 71.08%, respectively. The control effects of both reagents were significantly better than other test reagents and control re- agent Jinggangmycin, and they had no adverse effect on growth and development of rice. Considering from the aspects of control effect and economy, 20% Jinggang- mycin ~ prochloraz WP was suggested to be used to control rice sheath blight, its recommended dosage was 600 -750 g/hm2, and the reagent volume was 750kg with coarse spraying.
基金support from diverse funding sources,including the National Key Program for S&T Research and Development of the Ministry of Science and Technology(MOST),Yifang Wang's Science Studio of the Ten Thousand Talents Project,the CAS Key Foreign Cooperation Grant,the National Natural Science Foundation of China(NSFC)Beijing Municipal Science&Technology Commission,the CAS Focused Science Grant,the IHEP Innovation Grant,the CAS Lead Special Training Programthe CAS Center for Excellence in Particle Physics,the CAS International Partnership Program,and the CAS/SAFEA International Partnership Program for Creative Research Teams.
文摘The Circular Electron Positron Collider(CEPC)is a large scientific project initiated and hosted by China,fostered through extensive collaboration with international partners.The complex comprises four accelerators:a 30 GeV Linac,a 1.1 GeV Damping Ring,a Booster capable of achieving energies up to 180 GeV,and a Collider operating at varying energy modes(Z,W,H,and tt).The Linac and Damping Ring are situated on the surface,while the subterranean Booster and Collider are housed in a 100 km circumference underground tunnel,strategically accommodating future expansion with provisions for a potential Super Proton Proton Collider(SPPC).The CEPC primarily serves as a Higgs factory.In its baseline design with synchrotron radiation(SR)power of 30 MW per beam,it can achieve a luminosity of 5×10^(34)cm^(-2)s^(-1)per interaction point(IP),resulting in an integrated luminosity of 13 ab^(-1)for two IPs over a decade,producing 2.6 million Higgs bosons.Increasing the SR power to 50 MW per beam expands the CEPC's capability to generate 4.3 million Higgs bosons,facilitating precise measurements of Higgs coupling at sub-percent levels,exceeding the precision expected from the HL-LHC by an order of magnitude.This Technical Design Report(TDR)follows the Preliminary Conceptual Design Report(Pre-CDR,2015)and the Conceptual Design Report(CDR,2018),comprehensively detailing the machine's layout,performance metrics,physical design and analysis,technical systems design,R&D and prototyping efforts,and associated civil engineering aspects.Additionally,it includes a cost estimate and a preliminary construction timeline,establishing a framework for forthcoming engineering design phase and site selection procedures.Construction is anticipated to begin around 2027-2028,pending government approval,with an estimated duration of 8 years.The commencement of experiments and data collection could potentially be initiated in the mid-2030s.
基金supported by the National Key R&D Program of China (No. 2020YFA0714500)National Natural Science Foundation of China (Nos. 61875212 and U1831211)Shanghai Strategic Emerging Industry Development Special Fund (No. 31011442501217020191D3101001)。
文摘Measuring the topological charge(TC) of optical vortex beams by the edge-diffraction pattern of a single plate is proposed and demonstrated. The diffraction fringes can keep well discernible in a wide three-dimensional range in this method. The redundant fringes of the diffracted fork-shaped pattern in the near-field can determine the TC value, and the orientation of the fork tells the handedness of the vortex. The plate can be opaque or translucent, and the requirement of the translucent plate for TC measurement is analyzed. Measurement of TCs up to ±40 is experimentally demonstrated by subtracting the upper and lower fringe numbers with respect to the center of the light. The plate is easy to get, and this feasible measurement can bring great convenience and efficiency for researchers.
基金supported by the National Key R&D Program of China(No.2020YFA0714500)the Shanghai Strategic Emerging Industry Development Special Fund(No.31011442501217020191D3101001)+1 种基金the National Natural Science Foundation of China(Nos.61875212 and U1831211)the International Partnership Program of Chinese Academy of Sciences(No.181231KYSB20200040)
文摘In this paper,a 2D angle amplifier based on peristrophic multiplexed volume Bragg gratings is designed and prepared,in which a calculation method is firstly proposed to optimize the number of channels to a minimum.The induction of peristrophic multiplexing reduces the performance difference in one bulk of the grating,whereas there is no need to deliberately optimize the fabrication process.It is revealed that a discrete 2D angle deflection range of±30°is obtained and the relative diffraction efficiency of all the grating channels reaches more than 55%with a root-meansquare deviation of less than 3.4%in the same grating.The deviation of the Bragg incidence and exit angles from the expected values is less than 0.07°.It is believed that the proposed 2D angle amplifier has the potential to realize high-performance and large-angle beam steering in high-power laser beam scanning systems.
文摘This work presents a brief introduction on three kinds of newly developed Nd^(3+)-doped laser glasses in Shanghai Institute of Optics and Fine Mechanics(SIOM), China. Two Nd^(3+)-doped phosphate glasses with lower thermal expansion coefficient and thermal shock resistance 4 times higher than that of N31 glass are developed for laser processing.Nd:Silicate and Nd:Aluminate glasses with peak emission wavelength at 1061 and 1065 nm, effective emission bandwidth of 34 and 50 nm, respectively, are developed for Exawatt-class laser system application. Fluorophosphate glasses with low nonlinear refractive index(n_2=0.6–0.86) and long fluorescence lifetime(430–510 μs) are investigated for the purpose of decreasing B integral in high-power laser system. The properties of all these glasses are presented and compared with those of commercial neodymium laser glasses.