Force analysis using a compact tension model, as recommended by ASTM, was carried out on a crack stop hole. The stress before, and after, drilling the hole was compared in terms of stress concentration and stress grad...Force analysis using a compact tension model, as recommended by ASTM, was carried out on a crack stop hole. The stress before, and after, drilling the hole was compared in terms of stress concentration and stress gradient. The optimum drilling location and diameter were studied through analysis of different locations and diameters. By analyzing the effects of flank holes and an additional hole, drilling advice was proposed and fatigue testing of the cracks in a steel bridge deck with a crack stop hole was conducted. The results show that the stress at the crack tip with a crack stop hole decreased, and the major principal stress around the hole was distributed accordingly. The optimum position of the crack stop hole centre was where the centre of the crack stop hole was situated behind the crack and the hole edge coincided with the crack tip. Therefore, hole diameters larger than 8 mm, or those weakening the section by 10%, were suggested as the best diameters. In terms of multi-hole crack stopping, a flank hole was not recommended. The optimum horizontal position of flank holes was at a distance of 1/4 of a single hole diameter from, and in front of, the single hole. Besides, the experiment showed that crack stop hole could only prevent cracks from growing and had no influence on crack growth rate.展开更多
To evaluate the effect of treating long cracks with the impact crack-closure retrofit(ICR)technique,three rib-to-deck welded specimens with a crack length of about 100 mm were tested.The metallographic structure,crack...To evaluate the effect of treating long cracks with the impact crack-closure retrofit(ICR)technique,three rib-to-deck welded specimens with a crack length of about 100 mm were tested.The metallographic structure,crack section,crack propagation life,and stress variation were analyzed.Finite-element models were also developed,and some optimal values of certain parameters are suggested according to the simulated results.The results show that new crack sources are generated on both sides of the ICR-treated region because of the stress distribution.The fatigue lives of cracked specimens with long cracks are significantly improved by the technique.Considerable residual compressive stress is also induced,and so it is suggested that the optimal impact angle to be applied to real bridges should be 70°.The stress at the weld root is distributed uniformly with the crack closed,and the optimal crack-closure depth is 4 mm.To evaluate the effect of different crack-closure depths in tests,it is recommended that a hot-spot stress method which is extrapolated by three reference points should be adopted.展开更多
基金Projects(51278166,51478163)supported by the National Natural Science Foundation of ChinaProject(2015B17414)supported by the Fundamental Research Funds for the Central Universities,China
文摘Force analysis using a compact tension model, as recommended by ASTM, was carried out on a crack stop hole. The stress before, and after, drilling the hole was compared in terms of stress concentration and stress gradient. The optimum drilling location and diameter were studied through analysis of different locations and diameters. By analyzing the effects of flank holes and an additional hole, drilling advice was proposed and fatigue testing of the cracks in a steel bridge deck with a crack stop hole was conducted. The results show that the stress at the crack tip with a crack stop hole decreased, and the major principal stress around the hole was distributed accordingly. The optimum position of the crack stop hole centre was where the centre of the crack stop hole was situated behind the crack and the hole edge coincided with the crack tip. Therefore, hole diameters larger than 8 mm, or those weakening the section by 10%, were suggested as the best diameters. In terms of multi-hole crack stopping, a flank hole was not recommended. The optimum horizontal position of flank holes was at a distance of 1/4 of a single hole diameter from, and in front of, the single hole. Besides, the experiment showed that crack stop hole could only prevent cracks from growing and had no influence on crack growth rate.
基金Projects(51478163,51678216)supported by the National Natural Science Foundation of ChinaProject(2017Y09)supported by the Transport Science Research Project of Jiangsu Province,China
文摘To evaluate the effect of treating long cracks with the impact crack-closure retrofit(ICR)technique,three rib-to-deck welded specimens with a crack length of about 100 mm were tested.The metallographic structure,crack section,crack propagation life,and stress variation were analyzed.Finite-element models were also developed,and some optimal values of certain parameters are suggested according to the simulated results.The results show that new crack sources are generated on both sides of the ICR-treated region because of the stress distribution.The fatigue lives of cracked specimens with long cracks are significantly improved by the technique.Considerable residual compressive stress is also induced,and so it is suggested that the optimal impact angle to be applied to real bridges should be 70°.The stress at the weld root is distributed uniformly with the crack closed,and the optimal crack-closure depth is 4 mm.To evaluate the effect of different crack-closure depths in tests,it is recommended that a hot-spot stress method which is extrapolated by three reference points should be adopted.