期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Comparison of Goldmann applanation tonometry,rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes 被引量:3
1
作者 fatih ozcura Nilgün Yildirim +1 位作者 Afsun Sahin Ertugrul Colak 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期299-304,共6页
AIM: To compare the intraocular pressure(IOP)measurements obtained with the rebound tonometry(RT), dynamic contour tonometry(DCT) and Goldmann applanation tonometry(GAT) in normal and glaucomatous eyes and investigate... AIM: To compare the intraocular pressure(IOP)measurements obtained with the rebound tonometry(RT), dynamic contour tonometry(DCT) and Goldmann applanation tonometry(GAT) in normal and glaucomatous eyes and investigate the effects of central corneal thickness(CCT) and corneal curvature(CC) on IOP measurements.METHODS: One hundred and twenty-four eyes of 124 subjects were enrolled in this cross-sectional study.Fifty-six of participants were healthy individuals and 68 of them were glaucomatous patients. IOP was measured on each subject always in the same order, ICare RT-Pascal DCT-GAT, after a minimum interval of 10 min between measurements. CCT and CC were measured using a rotating Scheimpflug camera before the IOP measurements in all subjects. One way repeated measures ANOVA, Pearson correlation coefficient and regression analysis, and Bland-Altman analysis was used for the statistical assessment.RESULTS: Mean IOP for all enrolled eyes was 16.00±3.80 mm Hg for GAT, 16.99 ±4.91 mm Hg for RT, and20.40 ±4.44 mm Hg for DCT. Mean differences between GAT and RT was-1.75±3.41 mm Hg in normal(P 【0.001)and-0.37 ±3.00 mm Hg in glaucomatous eyes(P =0.563).Mean differences between GAT and DCT was-4.06 ±3.42 mm Hg in normal(P 【 0.001) and-4.67 ±3.12 mm Hg in glaucomatous eyes(P 【0.001). GAT and RT were significantly positive correlated with CCT in normal(r2=0.101, P =0.017 and r2=0.331, P 【0.001, respectively) and glaucomatous eyes(r2=0.084, P =0.016 and r2=0.123,P =0.003, respectively). DCT was also significantly positive correlated with CCT in normal eyes( r2=0.179,P =0.001) but not in glaucomatous eyes(r2=0.029, P =0.165).All tonometers were unaffected by CC.CONCLUSION: IOP measurements by RT and DCT were significantly higher than GAT. DCT has highest IOP measurements among these tonometers. RT was most influenced tonometer from CCT although all tonometers were significantly positive correlated with CCT except DCT in glaucomatous eyes. CC did not influence IOP measurements. 展开更多
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部