A study was carried out to control the noise produced by the ventilators at the Luling coalmine, which had caused serious noise pollution to the residents living around the mine for a long time. The main noise source ...A study was carried out to control the noise produced by the ventilators at the Luling coalmine, which had caused serious noise pollution to the residents living around the mine for a long time. The main noise source was found to be the dynamic noise at the outlet of the diffuser. The frequency of its peak value was 250 Hz. A special brick with a resonant frequency of 250 Hz was designed to eliminate this noise. The diffusion of a lower frequency noise has been successfully controlled by the installation of a noise-eliminating tower above the diffuser outlet. The detection results show that the noise in the nearby residential area has been lowered to an average 55.3dB(A) in the daytime from 69.8dB(A) and to 48.4dB(A) at night from 65.8dB(A).展开更多
文摘A study was carried out to control the noise produced by the ventilators at the Luling coalmine, which had caused serious noise pollution to the residents living around the mine for a long time. The main noise source was found to be the dynamic noise at the outlet of the diffuser. The frequency of its peak value was 250 Hz. A special brick with a resonant frequency of 250 Hz was designed to eliminate this noise. The diffusion of a lower frequency noise has been successfully controlled by the installation of a noise-eliminating tower above the diffuser outlet. The detection results show that the noise in the nearby residential area has been lowered to an average 55.3dB(A) in the daytime from 69.8dB(A) and to 48.4dB(A) at night from 65.8dB(A).