Background Ruminal microbiota in early life plays critical roles in the life-time health and productivity of ruminant animals.However,understanding of the relationship between gut microbiota and ruminant phenotypes is...Background Ruminal microbiota in early life plays critical roles in the life-time health and productivity of ruminant animals.However,understanding of the relationship between gut microbiota and ruminant phenotypes is very limited.Here,the relationship between the rectum microbiota,their primary metabolites,and growth rate of a total of 76 young dairy goats(6-month-old)were analyzed,and then 10 goats with the highest or lowest growth rates respectively were further compared for the differences in the rectum microbiota,metabolites,and animal’s immune parameters,to investigate the potential mechanisms by which the rectum microbiota contributes to the health and growth rate.Results The analysis of Spearman correlation and microbial co-occurrence network indicated that some keystone rectum microbiota,including unclassified Prevotellaceae,Faecalibacterium and Succinivibrio,were the key modulators to shape the rectum microbiota and closely correlated with the rectum SCFA production and serum IgG,which contribute to the health and growth rate of young goats.In addition,random forest machine learning analysis suggested that six bacterial taxa in feces could be used as potential biomarkers for differentiating high or low growth rate goats,with 98.3%accuracy of prediction.Moreover,the rectum microbiota played more important roles in gut fermentation in early life(6-month-old)than in adulthood stage(19-month-old)of goats.Conclusion We concluded that the rectum microbiota was associated with the health and growth rate of young goats,and can be a focus on the design of the early-life gut microbial intervention.展开更多
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application...Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker.展开更多
To ensure their sound and continuous operation to the greatest extent,VSC-based DC girds have extremely stringent requirements for transmission line relay protection.In terms of guaranteeing their reliability,accurate...To ensure their sound and continuous operation to the greatest extent,VSC-based DC girds have extremely stringent requirements for transmission line relay protection.In terms of guaranteeing their reliability,accurate identification of lightning strikes on DC transmission lines is one of the urgent key problems to be solved.An effective ultra-high-speed identification scheme of lightning strikes suitable for the VSC-based DC grid is proposed in this paper.First,an 1-mode reverse voltage traveling wave(RVTW)is constructed applying the pole-mode transformation theory.Next,fault traveling wave propagation characteristics along the DC transmission line are analyzed in depth utilizing Peterson's law.Then,differences of time-frequency electromagnetic transient characteristics of 1-mode RVTWs between disturbances and faults caused by lightning strikes are distinguished in detail by means of the classical wavelet transformation multi-resolution analysis theory.Finally,extensive simulations are carried out to evaluate the performance of the proposed identification scheme,and by which its excellent rapidity,reliability and robustness are validated.Index Terms-Lightning-strike identification,Multi-resolution analysis,Relay protection,Traveling-wave protection,VsC-based DC grid,Wavelet transformation.展开更多
Grid-forming control(GFC)is promising for power electronics based power systems with high renewable energy penetration.Naturally,the impedance modeling for GFC is necessary and has gained significant attention recentl...Grid-forming control(GFC)is promising for power electronics based power systems with high renewable energy penetration.Naturally,the impedance modeling for GFC is necessary and has gained significant attention recently.However,most of the impedance analyses for GFC are based on a twolevel converter(TLC)rather than a modular multilevel converter(MMC).MMC differs from TLC with respect to its dominant multi-frequency response.It is necessary to analyze the impedance of GFC-based MMC owing to its superiority in highvoltage direct current(HVDC)transmission to interlink two weak AC systems with high renewable energy penetration.As the main contribution,this paper presents the AC-and DC-side impedance analyses for the GFC-based MMC with both power and DC voltage control using the harmonic transfer function(HTF),and compares the impedances of GFC-based MMC and TLC.It is inferred that although the impedance is mainly influenced within 200 Hz,the instability still could occur owing to negative resistance triggered by relatively larger parameters.The difference in AC-side impedance with power and DC voltage control is not apparent with proper parameters,while the DC-side impedance differs significantly.The generalized Nyquist criterion is necessary for AC-side stability owing to the relatively large coupling terms under GFC.Moreover,the coupling between AC-and DC-side impedances is noneligible,especially considering the DC-side resonance around the system resonant peak.The effects of parameters,system strength,and virtual impedance on the impedance shaping are analyzed and verified through simulations.展开更多
The occurrence of high frequency resonances(HFRs)has been frequently observed in several MMC-HVDC projects.To avoid these HFRs,the controller design of an MMC must satisfy two requirements:1)The controller should rema...The occurrence of high frequency resonances(HFRs)has been frequently observed in several MMC-HVDC projects.To avoid these HFRs,the controller design of an MMC must satisfy two requirements:1)The controller should remain stable while in the high frequency range,and 2)MMC impedance should not possess a negative real part in the high frequency range.So far,majority of the related studies on MMC controller design have been unable to address these requirements precisely.This paper first describes the simplified high frequency MMC impedance model developed indigenously by the authors.Subsequently,the driving mechanism of two kinds of HFRs is revealed using the said developed model,including:1)MMC controller instability,and 2)Interaction instability between MMC and AC cables.Furthermore,the mathematical expressions outlining the controller stability constraint and positive damping constraint are proposed.Additionally,NSGA-III based multi-objective optimization algorithm is adopted,to identify the region most suitable for satisfying the proposed stability constraints under the MMC controller parameters.The proposed controller design method is capable of effectively evading the HFRs triggered by the incompatible MMC.The detailed time-domain simulations generated using PSCAD/EMTDC software validate the proposed designed method and endorse the improved results.展开更多
A design methodology and a feasible equivalent circuit are proposed to test the reliability of insulated gate bipolar transistors(IGBT)in actual modular multilevel converter(MMC)conditions,which is impossible for exis...A design methodology and a feasible equivalent circuit are proposed to test the reliability of insulated gate bipolar transistors(IGBT)in actual modular multilevel converter(MMC)conditions,which is impossible for existing IGBT test platforms due to unexplicit equivalent indexes and low reliability of test platforms.Characteristics of IGBT devices are extracted during MMC operation,and turn-off transient and effective current are highlighted as key indexes for the equivalent test.A feasible equivalent timing diagram and a corresponding test circuit are proposed,as well as the circuit's operation concept.The proposed equivalent test method is verified by a back-to-back experiment with twenty-four submodules,and results indicate the proposed method has good equivalence.Between the proposed circuit waveform and the back-to-back experiment waveform,all indexes have errors of less than 5.9%.Furthermore,the proposed circuit components have losses less than 0.7 times those of the device under test,making them reliable and suitable for long-term operation tests for IGBT devices in MMC.Index Terms-Equivalent test,IGBT,MMC,reliability.展开更多
Enterotypes,which are defined as bacterial clusters in the gut microbiome,have been found to have a close relationship to host metabolism and health.However,this concept has never been used in the rumen,and little is ...Enterotypes,which are defined as bacterial clusters in the gut microbiome,have been found to have a close relationship to host metabolism and health.However,this concept has never been used in the rumen,and little is known about the complex biological relationships between ruminants and their rumen bacterial clusters.In this study,we used young goats(n=99)as a model,fed them the same diet,and analyzed their rumen microbiome and corresponding bacterial clusters.The relationships between the bacterial clusters and rumen fermentation and growth performance in the goats were further investigated.Two bacterial clusters were identified in all goats:the P-cluster(dominated by genus Prevotella,n=38)and R-cluster(dominated by Ruminococcus,n=61).Compared with P-cluster goats,Rcluster goats had greater growth rates,concentrations of propionate,butyrate,and 18 free amino acids)and proportion of unsaturated fatty acids,but lower acetate molar percentage,acetate to propionate ratio,and several odd and branched chain and saturated fatty acids in rumen fluid(P<0.05).Several members of Firmicutes,including Ruminococcus,Oscillospiraceae NK4A214 group,and Christensenellaceae R-7 group were significantly higher in the R-cluster,whereas Prevotellaceae members,such as Prevotella and Prevotellaceae UCG-003,were significantly higher in P-cluster(P<0.01).Co-occurrence networks showed that R-cluster enriched bacteria had significant negative correlations with P-cluster enriched bacteria(P<0.05).Moreover,we found the concentrations of propionate,butyrate and free amino acids,and the proportions of unsaturated fatty acids were positively correlated with R-cluster enriched bacteria(P<0.05).The concentrations of acetate,acetate to propionate ratio,and the proportion of odd and branched chain and saturated fatty acids were positively correlated with P-cluster enriched bacteria(P<0.05).Overall,our results indicated that rumen bacterial clusters can influence rumen fermentation and growth performance of young goats,which may shed light on modulating the rumen microbiome in early life to improve the growth performance of ruminant animals.展开更多
Grid-forming(GFM)control based high-voltage DC(HVDC)systems and renewable energy sources(RESs)provide support for enhancing the stability of power systems.However,the interaction and coordination of frequency support ...Grid-forming(GFM)control based high-voltage DC(HVDC)systems and renewable energy sources(RESs)provide support for enhancing the stability of power systems.However,the interaction and coordination of frequency support between the GFM-based modular multilevel converter based HVDC(MMC-HVDC)and grid-following(GFL)based RESs or GFM-based RESs have not been fully investigated,which are examined in this study.First,the detailed AC-and DC-side impedances of GFM-based MMC-HVDC are analyzed.The impedance characteristics of GFL-and GFM-based wind turbines are next analyzed.Then,the influences of GFL-and GFM-based wind farms(WFs)on the DC-and AC-side stabilities of WF-integrated MMC-HVDC systems are compared and evaluated.The results show that the GFM-based wind turbine performs better than the GFL-based wind turbine.Accordingly,to support a receiving-end AC system,the corresponding frequency supporting strategies are proposed based on the GFM control for WF-integrated MMC-HVDC systems.The GFM-based WF outperforms the GFL-based WF in terms of stability and response time.Simulations in PSCAD/EMTDC demonstrate the DC-and AC-side stability issues and seamless grid support from the RESs,i.e.,WFs,to the receiving-end AC system.展开更多
Because of its controlled power factor and no commutation failure,current source converter(CSC)made up of reverse-blocking IGCTs(RB-IGCTs)offers broad application prospects in the field of HVDC system.Valve voltage an...Because of its controlled power factor and no commutation failure,current source converter(CSC)made up of reverse-blocking IGCTs(RB-IGCTs)offers broad application prospects in the field of HVDC system.Valve voltage and power operating range as the most important operating characteristics should be paid attention to but they are always contradictory.First,the relationship between valve voltage and modulation index is obtained.In particular,valve voltage of converter under the three typical modulation methods is compared,analyzed,and verified.Second,with the help of the independent control strategy and coordinated control strategy of both ends,power operating ranges of the three modulation methods are comprehensively analyzed and compared.Third,in order to solve power coupling at a low active power,the improved coordination control strategy at both ends in this paper is proposed and the relationships among active power,reactive power,DC current and phase angle difference are given in detail.Finally,a 500 kV/3 kA simulation system was built in PSCAD/EMTDC to obtain comparison results of the key operating characteristics of CSC under different modulation methods and the converter can realize unity power operation under random active power after adopting the improved coordinated control strategy,and DC current does not decrease to zero,verifying effectiveness of the coordinated control strategy.展开更多
With variation of parameters,DC-DC converters may change from a stable state to an unstable state,which severely degrades the performances of the converter system.In this article,by establishing the state-space averag...With variation of parameters,DC-DC converters may change from a stable state to an unstable state,which severely degrades the performances of the converter system.In this article,by establishing the state-space average model,the stability and bifurcation of a boost and a buck-boost converter with energy balance control(EBC)is studied,respectively.Then the stability boundary and stable parameter domains are accurately predicted.The obtained stability region provides a parameter regulating range for converter design.Furthermore,compared with the one-cycle control(OCC)method,the EBC possesses an extended stable parameter domain,while avoiding unstable behaviors such as Hopf bifurcation,Quasi-periodic Oscillation even chaos,etc.The theoretic analysis is well validated through simulation and experiment.展开更多
Monascus is one of the most essential microbial resources in China,with thousands of years of history.Modern science has proved that Monascus can produce pigment,ergosterol,monacolin K,-aminobutyric acid,and other fun...Monascus is one of the most essential microbial resources in China,with thousands of years of history.Modern science has proved that Monascus can produce pigment,ergosterol,monacolin K,-aminobutyric acid,and other functionally active substances.Currently,Monascus is used to produce a variety of foods,health products,and pharmaceuticals,and its pigments are widely used as food additives.However,Monascus also makes a harmful polyketide component called citrinin in the fermentation process;citrinin has toxic effects on the kidneys such as teratogenicity,carcinogenicity,and mutagenicity(Gong et al.,2019).The presence of citrinin renders Monascus and its products potentially hazardous,which has led many countries to set limits and standards on citrinin content.展开更多
As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out...As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids.展开更多
This paper proposes the design of a novel DC current flow controller(CFC)and evaluates the control performance of balancing and regulating the DC branch currents using the DC CFC in a meshed multi-terminal HVDC(MTDC)g...This paper proposes the design of a novel DC current flow controller(CFC)and evaluates the control performance of balancing and regulating the DC branch currents using the DC CFC in a meshed multi-terminal HVDC(MTDC)grid.The DC CFC consists of two identical full bridge DC-DC converters with the capacitors of the two converters being connected in parallel.The scalability of the DC CFC is easily achievable due to the identical bridge converter topology;the cost of this DC CFC is also relatively low due to its simple physical structure and low voltage ratings.The control performance of the DC CFC is tested on a meshed 3-terminal(3-T)HVDC grid,which is based on modular multilevel converters(MMC).The DC branch current control in the meshed MTDC grid is achieved using the proposed control strategy of the DC CFC,and is verified through case studies on the real-time digital simulator(RTDS).展开更多
Due to their high controllability and flexibility,DC power grids have broad application prospects in the fields of networking of renewable energy and the power supply for oceanic archipelagos and future cities.This pa...Due to their high controllability and flexibility,DC power grids have broad application prospects in the fields of networking of renewable energy and the power supply for oceanic archipelagos and future cities.This paper describes the system topology,control strategy,DC breaker configuration,and research,development and testing of converter valves and DC breaker equipment of the Zhoushan multi-terminal DC transmission system.Zhejiang Zhoushan has unique geographical and developmental features to demonstrate the irreplaceable technical advantages of a DC power grid for providing reliable power supply.The experience gained from the Zhoushan DC power grid project can offer valuable insights into the development and utilization of this technology worldwide.展开更多
Reducing carbon emissions in the power sector is critical for transitioning to a sustainable and low-carbon future.Estimating carbon efficiency of demand side response(DSR)in the power system is an important step towa...Reducing carbon emissions in the power sector is critical for transitioning to a sustainable and low-carbon future.Estimating carbon efficiency of demand side response(DSR)in the power system is an important step towards realizing potential environmental benefits.Marginal emission factor(MEF)is an effective tool for estimating incremental changes in carbon emissions as a result of a change in demand.However,estimation methods currently used for evaluating MEF can be improved upon,specifically,by factoring in the ramp-rate constraint of generators in the fuel cost based merit order dispatch.In this paper is described a new method for MEF assessment under ramp-rate constraints;the method is then compared with two conventional estimations in a British power system.Three fuel price scenarios are used to conduct a sensitivity analysis of MEFs to fuel prices.Conclusions are drawn that can pave the way for future improvements in estimating MEF in power systems.展开更多
The use of overhead lines for power transmission in the future high-voltage and large-capacity voltagesource converter(VSC)-based direct current(DC) grid will significantly increase the probability of temporary faults...The use of overhead lines for power transmission in the future high-voltage and large-capacity voltagesource converter(VSC)-based direct current(DC) grid will significantly increase the probability of temporary faults.To eliminate potential adverse impacts such as erroneous protection, line-insulation failure, and even damage to power electronic devices resulting from a DC breaker reclosing operation with the traditional sequential autoreclosing strategy, a new sequential auto-reclosing strat-egy for hybrid HVDC breakers(HHBs) in VSC-based DC grids is proposed. This strategy is based on the step-by-step operation of the transfer branch in the HHB. As a result,du/dt resulting from the HHB reclosing operation is greatly reduced, and therefore those potential negative impacts can be eliminated. Several other advantages are also presented.The feasibility and validity of the proposed strategy are verified in a four-terminal annular VSC-based DC grid electromagnetic transient model.展开更多
High Voltage Direct Current(HVDC) grids are the most effective solutions for collection, integration and transmission of large scale remote renewable resources to load centers. A HVDC grid test model can provide a com...High Voltage Direct Current(HVDC) grids are the most effective solutions for collection, integration and transmission of large scale remote renewable resources to load centers. A HVDC grid test model can provide a common reference and study platform for researchers to compare the performance and characteristics of a DC grid with different DC control functions and protection strategies. It can also provide reference cases for testing of simulators and digital programs. This paper proposes a comprehensive HVDC grid test model and the associated four sub test models for system studies to meet the research purposes and requirements for different DC grid application scenarios. The design concept, topologies, configurations and functions of the test models are described in detail and their basic system data for load flow studies are provided. Finally load flow simulation studies with PSS/E(Power System Simulator/Engineering) program for each of the models are undertaken and the corresponding results are presented and analyzed in the paper.展开更多
Employing the AC/DC impedance analysis method,extensive research has been conducted on issues pertaining to harmonic resonance observed in wind farm-connected MMCHVDC systems over the past 5 years.In general,this meth...Employing the AC/DC impedance analysis method,extensive research has been conducted on issues pertaining to harmonic resonance observed in wind farm-connected MMCHVDC systems over the past 5 years.In general,this method divides the studied system into two subsystems at AC and DC sections.Subsequently,the impedance produced by these subsystems can be used to determine the system stability by implementing Nyquist criterion or generalized Nyquist stability criterion.However,the existing impedance analysis methods usually assume the subsystems to be stable and disregard certain special cases with potentially unstable subsystems,where the unstable poles of these subsystems must be evaluated before applying Nyquist criterion.In view of this consideration,a simplified method for identifying unstable subsystem poles is presented in this paper.Hence,the shortcoming of existing impedance analyses is rectified by considering the unstable subsystem poles.The proposed method and the stability analyses are validated by the electromagnetic transient simulation performed in PSCAD/EMTDC.展开更多
Large time delay is one of the inherent features of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system and is the main factor leading to the unfavorable’negative resistance and inducta...Large time delay is one of the inherent features of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system and is the main factor leading to the unfavorable’negative resistance and inductance’characteristic of MMC impedance.Research indicates that this characteristic interacting with the capacitive characteristics of an AC system is the cause of high frequency resonance(HFR)in the Yu-E HVDC project.As the current controller is one of the main factors that affects the MMC impedance,a compensation control to imitate the paralleled impedance at the point of common coupling(PCC)is proposed.Therefore,the structure and parameter design of the compensation controller are core to realizing HFR suppression.There are two potentially risky frequency ranges of HFRs(around 700 Hz and 1.8 kHz)in the studied AC system within 2.0 kHz.The core concept of HFR suppression is to make the phase angle of MMC impedance smaller than 90◦in the two risky frequency ranges according to impedance stability theory.Hence,the design parameters aim to coordinate the phase angle of MMC impedance in the two risky frequency ranges.In this paper,three types of compensation controller are studied to suppress HFRs,namely,first-order low pass filter(LPF),second-order LPF,and third-order band pass filter.The results of parameter design show that the first-order LPF cannot suppress both HFRs simultaneously.The second-order LPF can suppress both HFRs,however,it introduces a DC component into the current control loop.Therefore,a high pass filter is added to form the recommended third-order controller.All parameter ranges of the compensation controller are derived using analytical expressions.Finally,the correctness of the parameter design is proofed using time-domain simulations.展开更多
With the rapid development of hydropower in the southwest of China, the energy transmitted by ultra high volt- age direct current (UHVDC) is ever increasing. At the same time, the power grid continues to expand westwa...With the rapid development of hydropower in the southwest of China, the energy transmitted by ultra high volt- age direct current (UHVDC) is ever increasing. At the same time, the power grid continues to expand westward, creating a service area. The stability of the Southwest China Power Grid is becoming a major issue. It is necessary to coordinate the development of hydropower and the construction of cross-region interconnections to optimize the grid structure. The Yu-E denotes the connection between the two region Yu (Chongqing) and E (Hubei) in China. The Yu-E project is a back-to-back voltage source converter based high voltage direct current (VSC-HVDC) project designed to realize an asynchronous connection of the Southwest and Central China Power Grids. The project will improve the bi-directional power support capability and optimize the grid structure. In addition, the Yu-E project will improve hydropower cross-region transmission capacity and enable the Southwest China Power Grid to utilize the power from the Three Gorges in the Central China Power Grid. In this paper, the fault isolation, low-frequency oscillation, sub-synchronous oscillation and short-circuit level are investigated and analyzed. Meanwhile, the impact of the Yu-E project on AC systems is studied in detail. In the end, the overall system design of the Yu-E project is introduced. The research results show that the Yu-E project can increase the transmission capability of the Southwest and Central China Power Grids, and enhance the stability of asynchronously interconnected AC systems. At the same time, the Yu-E project also serves as a demonstration project for the future development and application of VSC technology for the world.展开更多
基金supported by the National Natural Science Foundation of China(32072761,32272829)the National Key Research and Development Program of China(2017YFD500500).
文摘Background Ruminal microbiota in early life plays critical roles in the life-time health and productivity of ruminant animals.However,understanding of the relationship between gut microbiota and ruminant phenotypes is very limited.Here,the relationship between the rectum microbiota,their primary metabolites,and growth rate of a total of 76 young dairy goats(6-month-old)were analyzed,and then 10 goats with the highest or lowest growth rates respectively were further compared for the differences in the rectum microbiota,metabolites,and animal’s immune parameters,to investigate the potential mechanisms by which the rectum microbiota contributes to the health and growth rate.Results The analysis of Spearman correlation and microbial co-occurrence network indicated that some keystone rectum microbiota,including unclassified Prevotellaceae,Faecalibacterium and Succinivibrio,were the key modulators to shape the rectum microbiota and closely correlated with the rectum SCFA production and serum IgG,which contribute to the health and growth rate of young goats.In addition,random forest machine learning analysis suggested that six bacterial taxa in feces could be used as potential biomarkers for differentiating high or low growth rate goats,with 98.3%accuracy of prediction.Moreover,the rectum microbiota played more important roles in gut fermentation in early life(6-month-old)than in adulthood stage(19-month-old)of goats.Conclusion We concluded that the rectum microbiota was associated with the health and growth rate of young goats,and can be a focus on the design of the early-life gut microbial intervention.
基金supported by SGCC Scientific and Technological Project(52110116004W)
文摘Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker.
基金supported by the National Natural Science Foundation of China(No.52277075)the State Key Laboratory of Advanced Power Transmission Technology(Grant No.GEIRI-SKL-2020-012).
文摘To ensure their sound and continuous operation to the greatest extent,VSC-based DC girds have extremely stringent requirements for transmission line relay protection.In terms of guaranteeing their reliability,accurate identification of lightning strikes on DC transmission lines is one of the urgent key problems to be solved.An effective ultra-high-speed identification scheme of lightning strikes suitable for the VSC-based DC grid is proposed in this paper.First,an 1-mode reverse voltage traveling wave(RVTW)is constructed applying the pole-mode transformation theory.Next,fault traveling wave propagation characteristics along the DC transmission line are analyzed in depth utilizing Peterson's law.Then,differences of time-frequency electromagnetic transient characteristics of 1-mode RVTWs between disturbances and faults caused by lightning strikes are distinguished in detail by means of the classical wavelet transformation multi-resolution analysis theory.Finally,extensive simulations are carried out to evaluate the performance of the proposed identification scheme,and by which its excellent rapidity,reliability and robustness are validated.Index Terms-Lightning-strike identification,Multi-resolution analysis,Relay protection,Traveling-wave protection,VsC-based DC grid,Wavelet transformation.
基金supported by the State Grid Corporation Science and Technology Project(No.5100-202158335A-0-0-00).
文摘Grid-forming control(GFC)is promising for power electronics based power systems with high renewable energy penetration.Naturally,the impedance modeling for GFC is necessary and has gained significant attention recently.However,most of the impedance analyses for GFC are based on a twolevel converter(TLC)rather than a modular multilevel converter(MMC).MMC differs from TLC with respect to its dominant multi-frequency response.It is necessary to analyze the impedance of GFC-based MMC owing to its superiority in highvoltage direct current(HVDC)transmission to interlink two weak AC systems with high renewable energy penetration.As the main contribution,this paper presents the AC-and DC-side impedance analyses for the GFC-based MMC with both power and DC voltage control using the harmonic transfer function(HTF),and compares the impedances of GFC-based MMC and TLC.It is inferred that although the impedance is mainly influenced within 200 Hz,the instability still could occur owing to negative resistance triggered by relatively larger parameters.The difference in AC-side impedance with power and DC voltage control is not apparent with proper parameters,while the DC-side impedance differs significantly.The generalized Nyquist criterion is necessary for AC-side stability owing to the relatively large coupling terms under GFC.Moreover,the coupling between AC-and DC-side impedances is noneligible,especially considering the DC-side resonance around the system resonant peak.The effects of parameters,system strength,and virtual impedance on the impedance shaping are analyzed and verified through simulations.
基金supported by the National Natural Science Foundation of China (52207099).
文摘The occurrence of high frequency resonances(HFRs)has been frequently observed in several MMC-HVDC projects.To avoid these HFRs,the controller design of an MMC must satisfy two requirements:1)The controller should remain stable while in the high frequency range,and 2)MMC impedance should not possess a negative real part in the high frequency range.So far,majority of the related studies on MMC controller design have been unable to address these requirements precisely.This paper first describes the simplified high frequency MMC impedance model developed indigenously by the authors.Subsequently,the driving mechanism of two kinds of HFRs is revealed using the said developed model,including:1)MMC controller instability,and 2)Interaction instability between MMC and AC cables.Furthermore,the mathematical expressions outlining the controller stability constraint and positive damping constraint are proposed.Additionally,NSGA-III based multi-objective optimization algorithm is adopted,to identify the region most suitable for satisfying the proposed stability constraints under the MMC controller parameters.The proposed controller design method is capable of effectively evading the HFRs triggered by the incompatible MMC.The detailed time-domain simulations generated using PSCAD/EMTDC software validate the proposed designed method and endorse the improved results.
基金supported by Science and Technology Project of SGCC(Research on key technology of high-voltage and high-power IGBT intelligent module,No.5500-202140112A-0-0-00).
文摘A design methodology and a feasible equivalent circuit are proposed to test the reliability of insulated gate bipolar transistors(IGBT)in actual modular multilevel converter(MMC)conditions,which is impossible for existing IGBT test platforms due to unexplicit equivalent indexes and low reliability of test platforms.Characteristics of IGBT devices are extracted during MMC operation,and turn-off transient and effective current are highlighted as key indexes for the equivalent test.A feasible equivalent timing diagram and a corresponding test circuit are proposed,as well as the circuit's operation concept.The proposed equivalent test method is verified by a back-to-back experiment with twenty-four submodules,and results indicate the proposed method has good equivalence.Between the proposed circuit waveform and the back-to-back experiment waveform,all indexes have errors of less than 5.9%.Furthermore,the proposed circuit components have losses less than 0.7 times those of the device under test,making them reliable and suitable for long-term operation tests for IGBT devices in MMC.Index Terms-Equivalent test,IGBT,MMC,reliability.
基金The present study was supported by the National Natural Science Foundation of China(32072761,32272829)the National Key Research and Development Program of China(2017YFD500500).
文摘Enterotypes,which are defined as bacterial clusters in the gut microbiome,have been found to have a close relationship to host metabolism and health.However,this concept has never been used in the rumen,and little is known about the complex biological relationships between ruminants and their rumen bacterial clusters.In this study,we used young goats(n=99)as a model,fed them the same diet,and analyzed their rumen microbiome and corresponding bacterial clusters.The relationships between the bacterial clusters and rumen fermentation and growth performance in the goats were further investigated.Two bacterial clusters were identified in all goats:the P-cluster(dominated by genus Prevotella,n=38)and R-cluster(dominated by Ruminococcus,n=61).Compared with P-cluster goats,Rcluster goats had greater growth rates,concentrations of propionate,butyrate,and 18 free amino acids)and proportion of unsaturated fatty acids,but lower acetate molar percentage,acetate to propionate ratio,and several odd and branched chain and saturated fatty acids in rumen fluid(P<0.05).Several members of Firmicutes,including Ruminococcus,Oscillospiraceae NK4A214 group,and Christensenellaceae R-7 group were significantly higher in the R-cluster,whereas Prevotellaceae members,such as Prevotella and Prevotellaceae UCG-003,were significantly higher in P-cluster(P<0.01).Co-occurrence networks showed that R-cluster enriched bacteria had significant negative correlations with P-cluster enriched bacteria(P<0.05).Moreover,we found the concentrations of propionate,butyrate and free amino acids,and the proportions of unsaturated fatty acids were positively correlated with R-cluster enriched bacteria(P<0.05).The concentrations of acetate,acetate to propionate ratio,and the proportion of odd and branched chain and saturated fatty acids were positively correlated with P-cluster enriched bacteria(P<0.05).Overall,our results indicated that rumen bacterial clusters can influence rumen fermentation and growth performance of young goats,which may shed light on modulating the rumen microbiome in early life to improve the growth performance of ruminant animals.
基金supported by National Key R&D Program of China(No.2020YFB1506600)。
文摘Grid-forming(GFM)control based high-voltage DC(HVDC)systems and renewable energy sources(RESs)provide support for enhancing the stability of power systems.However,the interaction and coordination of frequency support between the GFM-based modular multilevel converter based HVDC(MMC-HVDC)and grid-following(GFL)based RESs or GFM-based RESs have not been fully investigated,which are examined in this study.First,the detailed AC-and DC-side impedances of GFM-based MMC-HVDC are analyzed.The impedance characteristics of GFL-and GFM-based wind turbines are next analyzed.Then,the influences of GFL-and GFM-based wind farms(WFs)on the DC-and AC-side stabilities of WF-integrated MMC-HVDC systems are compared and evaluated.The results show that the GFM-based wind turbine performs better than the GFL-based wind turbine.Accordingly,to support a receiving-end AC system,the corresponding frequency supporting strategies are proposed based on the GFM control for WF-integrated MMC-HVDC systems.The GFM-based WF outperforms the GFL-based WF in terms of stability and response time.Simulations in PSCAD/EMTDC demonstrate the DC-and AC-side stability issues and seamless grid support from the RESs,i.e.,WFs,to the receiving-end AC system.
基金supported in part by Science and Technology Project of State Grid Corporation of China.(5500202058059A0000).
文摘Because of its controlled power factor and no commutation failure,current source converter(CSC)made up of reverse-blocking IGCTs(RB-IGCTs)offers broad application prospects in the field of HVDC system.Valve voltage and power operating range as the most important operating characteristics should be paid attention to but they are always contradictory.First,the relationship between valve voltage and modulation index is obtained.In particular,valve voltage of converter under the three typical modulation methods is compared,analyzed,and verified.Second,with the help of the independent control strategy and coordinated control strategy of both ends,power operating ranges of the three modulation methods are comprehensively analyzed and compared.Third,in order to solve power coupling at a low active power,the improved coordination control strategy at both ends in this paper is proposed and the relationships among active power,reactive power,DC current and phase angle difference are given in detail.Finally,a 500 kV/3 kA simulation system was built in PSCAD/EMTDC to obtain comparison results of the key operating characteristics of CSC under different modulation methods and the converter can realize unity power operation under random active power after adopting the improved coordinated control strategy,and DC current does not decrease to zero,verifying effectiveness of the coordinated control strategy.
基金supported by the State Key Program of National Natural Science Foundation of China(Grant No.U1866210)National Natural Science Foundation of China(Grant No.62001169).
文摘With variation of parameters,DC-DC converters may change from a stable state to an unstable state,which severely degrades the performances of the converter system.In this article,by establishing the state-space average model,the stability and bifurcation of a boost and a buck-boost converter with energy balance control(EBC)is studied,respectively.Then the stability boundary and stable parameter domains are accurately predicted.The obtained stability region provides a parameter regulating range for converter design.Furthermore,compared with the one-cycle control(OCC)method,the EBC possesses an extended stable parameter domain,while avoiding unstable behaviors such as Hopf bifurcation,Quasi-periodic Oscillation even chaos,etc.The theoretic analysis is well validated through simulation and experiment.
基金supported by the Science and Technology Planning Project of Guizhou Province(No.2019-2776)the National Natural Science Foundation of China(No.81960692).
文摘Monascus is one of the most essential microbial resources in China,with thousands of years of history.Modern science has proved that Monascus can produce pigment,ergosterol,monacolin K,-aminobutyric acid,and other functionally active substances.Currently,Monascus is used to produce a variety of foods,health products,and pharmaceuticals,and its pigments are widely used as food additives.However,Monascus also makes a harmful polyketide component called citrinin in the fermentation process;citrinin has toxic effects on the kidneys such as teratogenicity,carcinogenicity,and mutagenicity(Gong et al.,2019).The presence of citrinin renders Monascus and its products potentially hazardous,which has led many countries to set limits and standards on citrinin content.
基金This work was supported by National Natural Science Foundation of China(No.51261130471).
文摘As a new generation of direct current(DC)transmission technology,voltage sourced converter(VSC)based high voltage direct current(HVDC)has been widely developed and applied all over the world.China has also carried out a deep technical research and engineering application in this area,and at present,it has been stepped into a fast growing period.This paper gives a general review over China’s VSC based HVDC in terms of engineering technology,application and future development.It comprehensively analyzes the technical difficulties and future development orientation on the aspects of the main configurations of VSC based HVDC system,topological structures of converters,control and protection technologies,flexible DC cables,converter valve tests,etc.It introduces the applicable fields and current status of China’s VSC based HVDC projects,and analyzes the application trends of VSC based HVDC projects both in China and all over the world according to the development characteristics and demands of future power grids.
基金supported by UK-China Smart Grid Project ERIFT via UK EPSRC,University of Birmingham SiGuang Li Scholarship and China Scholarship Council。
文摘This paper proposes the design of a novel DC current flow controller(CFC)and evaluates the control performance of balancing and regulating the DC branch currents using the DC CFC in a meshed multi-terminal HVDC(MTDC)grid.The DC CFC consists of two identical full bridge DC-DC converters with the capacitors of the two converters being connected in parallel.The scalability of the DC CFC is easily achievable due to the identical bridge converter topology;the cost of this DC CFC is also relatively low due to its simple physical structure and low voltage ratings.The control performance of the DC CFC is tested on a meshed 3-terminal(3-T)HVDC grid,which is based on modular multilevel converters(MMC).The DC branch current control in the meshed MTDC grid is achieved using the proposed control strategy of the DC CFC,and is verified through case studies on the real-time digital simulator(RTDS).
基金supported in part by the National Natural Science Foundation of China(No.51261130471)by the Science and Technology Research Project of the State Grid Corporation of China(No.SGRIPGKJ(2013)166).
文摘Due to their high controllability and flexibility,DC power grids have broad application prospects in the fields of networking of renewable energy and the power supply for oceanic archipelagos and future cities.This paper describes the system topology,control strategy,DC breaker configuration,and research,development and testing of converter valves and DC breaker equipment of the Zhoushan multi-terminal DC transmission system.Zhejiang Zhoushan has unique geographical and developmental features to demonstrate the irreplaceable technical advantages of a DC power grid for providing reliable power supply.The experience gained from the Zhoushan DC power grid project can offer valuable insights into the development and utilization of this technology worldwide.
基金This work was supported in part by the EPSRC UK and the NSFC,through the ERIFT project(51261130471).
文摘Reducing carbon emissions in the power sector is critical for transitioning to a sustainable and low-carbon future.Estimating carbon efficiency of demand side response(DSR)in the power system is an important step towards realizing potential environmental benefits.Marginal emission factor(MEF)is an effective tool for estimating incremental changes in carbon emissions as a result of a change in demand.However,estimation methods currently used for evaluating MEF can be improved upon,specifically,by factoring in the ramp-rate constraint of generators in the fuel cost based merit order dispatch.In this paper is described a new method for MEF assessment under ramp-rate constraints;the method is then compared with two conventional estimations in a British power system.Three fuel price scenarios are used to conduct a sensitivity analysis of MEFs to fuel prices.Conclusions are drawn that can pave the way for future improvements in estimating MEF in power systems.
基金supported by National Key R&D Program of China (No. 2017YFB0902400)
文摘The use of overhead lines for power transmission in the future high-voltage and large-capacity voltagesource converter(VSC)-based direct current(DC) grid will significantly increase the probability of temporary faults.To eliminate potential adverse impacts such as erroneous protection, line-insulation failure, and even damage to power electronic devices resulting from a DC breaker reclosing operation with the traditional sequential autoreclosing strategy, a new sequential auto-reclosing strat-egy for hybrid HVDC breakers(HHBs) in VSC-based DC grids is proposed. This strategy is based on the step-by-step operation of the transfer branch in the HHB. As a result,du/dt resulting from the HHB reclosing operation is greatly reduced, and therefore those potential negative impacts can be eliminated. Several other advantages are also presented.The feasibility and validity of the proposed strategy are verified in a four-terminal annular VSC-based DC grid electromagnetic transient model.
基金supported by the State Grid Corporation of China,through the 1000-Plan project(No.[2014]264)
文摘High Voltage Direct Current(HVDC) grids are the most effective solutions for collection, integration and transmission of large scale remote renewable resources to load centers. A HVDC grid test model can provide a common reference and study platform for researchers to compare the performance and characteristics of a DC grid with different DC control functions and protection strategies. It can also provide reference cases for testing of simulators and digital programs. This paper proposes a comprehensive HVDC grid test model and the associated four sub test models for system studies to meet the research purposes and requirements for different DC grid application scenarios. The design concept, topologies, configurations and functions of the test models are described in detail and their basic system data for load flow studies are provided. Finally load flow simulation studies with PSS/E(Power System Simulator/Engineering) program for each of the models are undertaken and the corresponding results are presented and analyzed in the paper.
文摘Employing the AC/DC impedance analysis method,extensive research has been conducted on issues pertaining to harmonic resonance observed in wind farm-connected MMCHVDC systems over the past 5 years.In general,this method divides the studied system into two subsystems at AC and DC sections.Subsequently,the impedance produced by these subsystems can be used to determine the system stability by implementing Nyquist criterion or generalized Nyquist stability criterion.However,the existing impedance analysis methods usually assume the subsystems to be stable and disregard certain special cases with potentially unstable subsystems,where the unstable poles of these subsystems must be evaluated before applying Nyquist criterion.In view of this consideration,a simplified method for identifying unstable subsystem poles is presented in this paper.Hence,the shortcoming of existing impedance analyses is rectified by considering the unstable subsystem poles.The proposed method and the stability analyses are validated by the electromagnetic transient simulation performed in PSCAD/EMTDC.
基金supported by the National Natural Science Foundation of China(No.U1866210).
文摘Large time delay is one of the inherent features of a modular multilevel converter(MMC)-based high voltage direct current(HVDC)system and is the main factor leading to the unfavorable’negative resistance and inductance’characteristic of MMC impedance.Research indicates that this characteristic interacting with the capacitive characteristics of an AC system is the cause of high frequency resonance(HFR)in the Yu-E HVDC project.As the current controller is one of the main factors that affects the MMC impedance,a compensation control to imitate the paralleled impedance at the point of common coupling(PCC)is proposed.Therefore,the structure and parameter design of the compensation controller are core to realizing HFR suppression.There are two potentially risky frequency ranges of HFRs(around 700 Hz and 1.8 kHz)in the studied AC system within 2.0 kHz.The core concept of HFR suppression is to make the phase angle of MMC impedance smaller than 90◦in the two risky frequency ranges according to impedance stability theory.Hence,the design parameters aim to coordinate the phase angle of MMC impedance in the two risky frequency ranges.In this paper,three types of compensation controller are studied to suppress HFRs,namely,first-order low pass filter(LPF),second-order LPF,and third-order band pass filter.The results of parameter design show that the first-order LPF cannot suppress both HFRs simultaneously.The second-order LPF can suppress both HFRs,however,it introduces a DC component into the current control loop.Therefore,a high pass filter is added to form the recommended third-order controller.All parameter ranges of the compensation controller are derived using analytical expressions.Finally,the correctness of the parameter design is proofed using time-domain simulations.
基金This work was supported in part by the National Natural Science Foundation of China(No.U1866210).
文摘With the rapid development of hydropower in the southwest of China, the energy transmitted by ultra high volt- age direct current (UHVDC) is ever increasing. At the same time, the power grid continues to expand westward, creating a service area. The stability of the Southwest China Power Grid is becoming a major issue. It is necessary to coordinate the development of hydropower and the construction of cross-region interconnections to optimize the grid structure. The Yu-E denotes the connection between the two region Yu (Chongqing) and E (Hubei) in China. The Yu-E project is a back-to-back voltage source converter based high voltage direct current (VSC-HVDC) project designed to realize an asynchronous connection of the Southwest and Central China Power Grids. The project will improve the bi-directional power support capability and optimize the grid structure. In addition, the Yu-E project will improve hydropower cross-region transmission capacity and enable the Southwest China Power Grid to utilize the power from the Three Gorges in the Central China Power Grid. In this paper, the fault isolation, low-frequency oscillation, sub-synchronous oscillation and short-circuit level are investigated and analyzed. Meanwhile, the impact of the Yu-E project on AC systems is studied in detail. In the end, the overall system design of the Yu-E project is introduced. The research results show that the Yu-E project can increase the transmission capability of the Southwest and Central China Power Grids, and enhance the stability of asynchronously interconnected AC systems. At the same time, the Yu-E project also serves as a demonstration project for the future development and application of VSC technology for the world.