We report a simple-to-perform technique to investigate the distribution of the azimuthal magnetic field induction,Bθ,and the induced magnetic force acting on the plasma current sheath(PCS)in a plasma focus(PF)dischar...We report a simple-to-perform technique to investigate the distribution of the azimuthal magnetic field induction,Bθ,and the induced magnetic force acting on the plasma current sheath(PCS)in a plasma focus(PF)discharge.This in situ measurement technique can undoubtedly be beneficial when other fast-imaging techniques are not available.techniques are not available.Experimental work was conducted in the low-energy Mather-type EAEA-PF1 device operated in argon.The axial distribution(Bθ)z along the coaxial electrodes system was measured with a four magnetic-probe set technique at different radial distances(r=2.625×10^(−2) to 4.125×10^(−2) m)within the annular space between the coaxial electrodes during the 1st and 2nd half cycles of the discharge current waveform,where inner electrode of coaxial electrode system has a+ve polarity and−ve polarity,respectively.Axial,radial and total magnetic force distribution profiles were estimated from Bθdata.Investigation of PCS shape in terms of its inclination(curvature)angle,θ,along the axial rundown phase and the correlation between the magnetic forces per unit volume acting on the PCS,the inclination angleθof the PCS,and the formation of a powerful PF action during the 1st and 2nd half cycles is carried out.Dependence of inclination angle,θ,on total magnetic force per unit volume acting on PCS axial motion was studied,separately,during the 1st and 2nd half cycles.展开更多
文摘We report a simple-to-perform technique to investigate the distribution of the azimuthal magnetic field induction,Bθ,and the induced magnetic force acting on the plasma current sheath(PCS)in a plasma focus(PF)discharge.This in situ measurement technique can undoubtedly be beneficial when other fast-imaging techniques are not available.techniques are not available.Experimental work was conducted in the low-energy Mather-type EAEA-PF1 device operated in argon.The axial distribution(Bθ)z along the coaxial electrodes system was measured with a four magnetic-probe set technique at different radial distances(r=2.625×10^(−2) to 4.125×10^(−2) m)within the annular space between the coaxial electrodes during the 1st and 2nd half cycles of the discharge current waveform,where inner electrode of coaxial electrode system has a+ve polarity and−ve polarity,respectively.Axial,radial and total magnetic force distribution profiles were estimated from Bθdata.Investigation of PCS shape in terms of its inclination(curvature)angle,θ,along the axial rundown phase and the correlation between the magnetic forces per unit volume acting on the PCS,the inclination angleθof the PCS,and the formation of a powerful PF action during the 1st and 2nd half cycles is carried out.Dependence of inclination angle,θ,on total magnetic force per unit volume acting on PCS axial motion was studied,separately,during the 1st and 2nd half cycles.