Needs in scintimammography applications,especially for small animal cardiac imaging,lead to develop a small field of view,high spatial resolution gamma camera with a pinhole collimator.However the ideal pinhole collim...Needs in scintimammography applications,especially for small animal cardiac imaging,lead to develop a small field of view,high spatial resolution gamma camera with a pinhole collimator.However the ideal pinhole collimator must keep a compromise between spatial resolution and sensitivity.In order to design a pinhole collimator with an optimized sensitivity and spatial resolution,the spatial resolution and the geometric sensitivity response as a function of the source to collimator distance has been obtained by means of Monte-Carlo simulation for a small field of view gamma camera with a pinhole collimator of various-hole diameters.The results show that the camera with pinhole of 1 mm,1.5 mm and 2 mm diameter has respectively spatial resolution of 1.5 mm,2.25 mm and 3 mm and geometric sensitivity of 0.016%,0.022%and 0.036%,while the source to collimator distance is 3 cm.We chose the pinhole collimator with hole diameter size of 1.2 mm for our the gamma camera designed based on the trade-off between sensitivity and resolution.展开更多
The gas magnification of multi-gap resistive plate chamber (MRPC) is very difficult to be measured using the present instruments thoroughly in the world. The gas magnifications about ~107 were obtained in the various ...The gas magnification of multi-gap resistive plate chamber (MRPC) is very difficult to be measured using the present instruments thoroughly in the world. The gas magnifications about ~107 were obtained in the various operation-high-voltages of multi-gap resistive plate chamber (MRPC) by means of Monte-Carlo simulation and the presented experiment method.展开更多
Currently,the neutron yield of Z-Pinch is lower than that of laser driven fusion.In the neutron imaging for this facility,the signal to noise ratio(SNR)has a significant influence on the expected spatial resolution of...Currently,the neutron yield of Z-Pinch is lower than that of laser driven fusion.In the neutron imaging for this facility,the signal to noise ratio(SNR)has a significant influence on the expected spatial resolution of the reconstructed fusion core,especially in the condition of low neutron yield.In this paper,mathematical model is purposed to describe the dependence of aperture parameters on the imaging SNR.The investigation shows that the imaging SNR is closely related to the size of contrast boundary on the point spread function.According to this,a novel non-uniform redundancy penumbra apertures array is designed.In addition,the imaging performances of this novel coded aperture,penumbra aperture and ring aperture are evaluated and compared by Monte Carlo method.The comparison shows that this novel aperture has significant advantage compared to the penumbra aperture which is commonly used for neutron imaging with low yield.The encouraging results can provide reference for the optimal design of the coded aperture used in the neutron imaging for Z-pinch driven fusion with low neutron yield.展开更多
基金Supported by National Foundation of Nature Science of China(No.10275063)
文摘Needs in scintimammography applications,especially for small animal cardiac imaging,lead to develop a small field of view,high spatial resolution gamma camera with a pinhole collimator.However the ideal pinhole collimator must keep a compromise between spatial resolution and sensitivity.In order to design a pinhole collimator with an optimized sensitivity and spatial resolution,the spatial resolution and the geometric sensitivity response as a function of the source to collimator distance has been obtained by means of Monte-Carlo simulation for a small field of view gamma camera with a pinhole collimator of various-hole diameters.The results show that the camera with pinhole of 1 mm,1.5 mm and 2 mm diameter has respectively spatial resolution of 1.5 mm,2.25 mm and 3 mm and geometric sensitivity of 0.016%,0.022%and 0.036%,while the source to collimator distance is 3 cm.We chose the pinhole collimator with hole diameter size of 1.2 mm for our the gamma camera designed based on the trade-off between sensitivity and resolution.
基金National Natural Science Foundation of China (10576022)
文摘The gas magnification of multi-gap resistive plate chamber (MRPC) is very difficult to be measured using the present instruments thoroughly in the world. The gas magnifications about ~107 were obtained in the various operation-high-voltages of multi-gap resistive plate chamber (MRPC) by means of Monte-Carlo simulation and the presented experiment method.
基金supported by the National Natural Science Foundation of China(Grant No.10975113)Innovative Research Team in University of Ministry of Education of China(Nuclear Energy Science and Engineering)(Grant No.IRT1280)
文摘Currently,the neutron yield of Z-Pinch is lower than that of laser driven fusion.In the neutron imaging for this facility,the signal to noise ratio(SNR)has a significant influence on the expected spatial resolution of the reconstructed fusion core,especially in the condition of low neutron yield.In this paper,mathematical model is purposed to describe the dependence of aperture parameters on the imaging SNR.The investigation shows that the imaging SNR is closely related to the size of contrast boundary on the point spread function.According to this,a novel non-uniform redundancy penumbra apertures array is designed.In addition,the imaging performances of this novel coded aperture,penumbra aperture and ring aperture are evaluated and compared by Monte Carlo method.The comparison shows that this novel aperture has significant advantage compared to the penumbra aperture which is commonly used for neutron imaging with low yield.The encouraging results can provide reference for the optimal design of the coded aperture used in the neutron imaging for Z-pinch driven fusion with low neutron yield.