期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
PREPARATION AND PROPERTIES OF MMA/1-PROPYLMETHACRYLATE-POSS COPOLYMER WITH ATOM TRANSFER RADICAL POLYMERIZATION
1
作者 He-xin Zhang ho-young lee +2 位作者 Young-jun Shin Dong-ho lee Seok Kyun Noh 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2008年第5期533-537,共5页
The methyl methacrylate(MMA)/1-propylmethacrylate-polyhedral oligomeric silsesquioxane(PM-POSS) copolymers were synthesized via atom transfer radical polymerization with CuBr as catalyst.The unreacted PM-POSS monomer ... The methyl methacrylate(MMA)/1-propylmethacrylate-polyhedral oligomeric silsesquioxane(PM-POSS) copolymers were synthesized via atom transfer radical polymerization with CuBr as catalyst.The unreacted PM-POSS monomer could be removed completely by washing the copolymerization product with n-hexane.The copolymers were characterized with ~1H-NMR,X-ray diffraction,differential scanning calorimetry,thermogravimetric analysis and gel permeation chromatography.With increasing PM-POSS feed ratio,the total conversi... 展开更多
关键词 Methyl methacrylate(MMA) Polyhedral oligomeric silsesquioxane(POSS) COPOLYMER ATRP
下载PDF
基于PC机的高分辨率海上地震数据的采集和处理
2
作者 ho-young lee 纪怀清 《国外油气勘探》 1998年第1期76-84,95,共10页
我们使用一台简单的PC机的采集和处理系统改进了高分辨率的浅海地震数据的质量。该系统由一台PC机、一个A/D转换器和一台磁—光盘机组成。该系统被设计为以每秒多达60000个采样的单道数据进行采集,并用一个简单程序完成地震数据处理。... 我们使用一台简单的PC机的采集和处理系统改进了高分辨率的浅海地震数据的质量。该系统由一台PC机、一个A/D转换器和一台磁—光盘机组成。该系统被设计为以每秒多达60000个采样的单道数据进行采集,并用一个简单程序完成地震数据处理。试验在东朝鲜海南部浦项附近进行。试验用的地震系统为空气枪和一台3.5kHz海底地层剖面仪。分析了震源的频谱特性。进行了包括增益恢复、反褶积、带通滤波和海浪滤波的简单数字信号处理。该系统处理的地震剖面质量与模拟剖面相比大有提高。用基于PC机的系统采集、处理高分辨率浅海地震资料既经济又适用。 展开更多
关键词 海洋勘探 地震数据采集 数据处理 模数转换器 磁换能器 光盘
下载PDF
Enzyme-amplified SERS immunoassay with Ag-Au bimetallic SERS hot spots 被引量:5
3
作者 Xuan-Hung Pham Eunil Hahm +8 位作者 Tae Han Kim Hyung-Mo Kim Sang Hun lee Sang Chul lee Homan Kang ho-young lee Dae Hong Jeong Hak Soo Choi Bong-Hyun Jun 《Nano Research》 SCIE EI CAS CSCD 2020年第12期3338-3346,共9页
Surface-enhanced Raman scattering(SERS)enables rapid detection of single molecules with high specificity.However,quantitative and sensitive SERS analysis has been a challenge due to the lack of reliable SERS-active ma... Surface-enhanced Raman scattering(SERS)enables rapid detection of single molecules with high specificity.However,quantitative and sensitive SERS analysis has been a challenge due to the lack of reliable SERS-active materials.In this study,we developed a quantitative SERS-based immunoassay using enzyme-guided Ag growth on Raman labeling compound(RLC)-immobilized gold nanoparticle(Au NP)-assembled silica NPs(SiO2@Au-RLC@Ag).The enzyme amplified Ag+reduction as well as Ag growth on the RLC-immobilized Au NP-assembled silica NPs(SiO2@Au-RLC),which resulted in a significant increase in SERS signal.In the presence of target antigens such as immunoglobulinG(IgG)or prostate-specific antigen(PSA),Ab1-Antigen-Ab2 immune complex with alkaline phosphatase triggered an enzyme-catalyzed reaction to convert 2-phospho-L-ascorbic acid(2-phospho-L-AA)to ascorbic acid(AA).As produced AA reduced Ag+to Ag,forming an Ag hot spot on the surface of SiO2@Au-RLC,which enhanced the SERS signal of SiO2@Au-RLC@Ag in a solution with a target antigen concentration.The plasmonic immunoassay for IgG detection showed a high linearity of SERS intensity in the range of 0.6 to 9.0 ng/mL with a detection limit(LOD)of 0.09 ng/mL,while an LOD of 0.006 ng/mL was obtained for PSA.The results indicate that the sensitivity of our novel SERS-based immunoassay is higher than that of conventional enzyme-based colorimetric immunoassays. 展开更多
关键词 surface-enhanced Raman scattering(SERS)-based immunoassay Au-Ag alloy surface-enhanced Raman scattering silica template immunoglobulin G(IgG)detection
原文传递
Erratum to: Enzyme-amplified SERS immunoassay with Ag-Au bimetallic SERS hot spots
4
作者 Xuan-Hung Pham Eunil Hahm +8 位作者 Tae Han Kim Hyung-Mo Kim Sang Hun lee SangChul lee Homan Kang ho-young lee Dae Hong Jeong Hak Soo Choi Bong-Hyun Jun 《Nano Research》 SCIE EI CAS CSCD 2021年第3期895-895,共1页
Erratum to Nano Research 2020,13(12):3338-3346 htts://doi.org/00.1007/s12274-020-3014-3 One author name and corresponding affiliation of the original version of this article were unfortunately mislabeled.
关键词 SERS BIMETALLIC
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部