A molecularly imprinted polymer (MIP), prepared around a cotinine template, has been synthesized. The feasibility of using the polymer for solid-phase extraction (SPE) of cotinine from biological samples has been ...A molecularly imprinted polymer (MIP), prepared around a cotinine template, has been synthesized. The feasibility of using the polymer for solid-phase extraction (SPE) of cotinine from biological samples has been investigated. The results show that cotinine can be quantitatively retained and eluted from the polymer. Experiments with human urine samples indicate that clean target analyte is obtained for HPLC with UV detection using the protocol.展开更多
A new indirect inhibitive immunoassay using surface plasmon resonance(SPR) coupled with molecularly imprinted polymer(MIP) was developed.A sulfamethoxazole(SMX) MIP coating capillary was produced and used as an ...A new indirect inhibitive immunoassay using surface plasmon resonance(SPR) coupled with molecularly imprinted polymer(MIP) was developed.A sulfamethoxazole(SMX) MIP coating capillary was produced and used as an in-tube solid phase extraction(SPE) device.The MIP coating formed a nanometer film on the inner wall of the capillary.The anti-SMX mono-antibody was inhibited by SMX extracted by the MIP coating in a dose-dependent manner.The calibration curve was generated by linear fit over the range of 0.04-10.00 ng/mL.The limit of detection was 0.01 ng/mL.This method has high sensitivity and can be performed automatically.展开更多
基金supported by the National Natural Science Foundation of China(No.20405013)the Scientific Foundation of State Tobacco Monopoly Administration of China(No.110200201017).
文摘A molecularly imprinted polymer (MIP), prepared around a cotinine template, has been synthesized. The feasibility of using the polymer for solid-phase extraction (SPE) of cotinine from biological samples has been investigated. The results show that cotinine can be quantitatively retained and eluted from the polymer. Experiments with human urine samples indicate that clean target analyte is obtained for HPLC with UV detection using the protocol.
基金supported by National Natural Science Foundation of China(No.20405013)
文摘A new indirect inhibitive immunoassay using surface plasmon resonance(SPR) coupled with molecularly imprinted polymer(MIP) was developed.A sulfamethoxazole(SMX) MIP coating capillary was produced and used as an in-tube solid phase extraction(SPE) device.The MIP coating formed a nanometer film on the inner wall of the capillary.The anti-SMX mono-antibody was inhibited by SMX extracted by the MIP coating in a dose-dependent manner.The calibration curve was generated by linear fit over the range of 0.04-10.00 ng/mL.The limit of detection was 0.01 ng/mL.This method has high sensitivity and can be performed automatically.