We report on using synthetic silicon for a high-precision X-ray polarimeter comprising a polarizer and an analyzer,each based on a monolithic channel-cut crystal used at multiple Brewster reflections with a Bragg angl...We report on using synthetic silicon for a high-precision X-ray polarimeter comprising a polarizer and an analyzer,each based on a monolithic channel-cut crystal used at multiple Brewster reflections with a Bragg angle very close to 45°.Experiments were performed at the BL09B bending magnet beamline of the Shanghai Synchrotron Radiation Facility using a Si(800)crystal at an X-ray energy of 12.914 keV.A polarization purity of 8.4×10^(-9)was measured.This result is encouraging,as the measured polarization purity is the best-reported value for the bending magnet source.Notably,this is the firstly systematic study on the hard X-ray polarimeter in China,which is crucial for exploring new physics,such as verifying vacuum birefringence.展开更多
Investigating deuteron–deuteron(DD)fusion reactions in a plasma environment similar to the early stages of the Big Bang is an important topic in nuclear astrophysics.In this study,we experimentally investigated such ...Investigating deuteron–deuteron(DD)fusion reactions in a plasma environment similar to the early stages of the Big Bang is an important topic in nuclear astrophysics.In this study,we experimentally investigated such reactions,using eight laser beams with the third harmonic impacting on a deuterated polyethylene target at the ShenGuang-II Upgrade laser facility.This work focused on the application of range-filter(RF)spectrometers,assembled from a 70 lm aluminum filter and two CR-39 nuclear track detectors,to measure the yields of primary DD-protons.Based on the track diameter calibration results of 3 MeV protons used to diagnose the tracks on the RF spectrometers,an approximate primary DD-proton yield of(8.5±1.7)×10^6 was obtained,consistent with the yields from similar laser facilities worldwide.This indicates that the RF spectrometer is an effective way to measure primary DD-protons.However,due to the low yields of D^3He-protons and its small track diameter,CR-39 detectors were unable to distinguish it from the background spots.Using other accurate detectors may help to measure these rare events.展开更多
基金supported by the Shanghai Municipal Science and Technology Major Project(No.2017SHZDZX02)the National Natural Science Foundation of China(No.12205360)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(No.2018297)。
文摘We report on using synthetic silicon for a high-precision X-ray polarimeter comprising a polarizer and an analyzer,each based on a monolithic channel-cut crystal used at multiple Brewster reflections with a Bragg angle very close to 45°.Experiments were performed at the BL09B bending magnet beamline of the Shanghai Synchrotron Radiation Facility using a Si(800)crystal at an X-ray energy of 12.914 keV.A polarization purity of 8.4×10^(-9)was measured.This result is encouraging,as the measured polarization purity is the best-reported value for the bending magnet source.Notably,this is the firstly systematic study on the hard X-ray polarimeter in China,which is crucial for exploring new physics,such as verifying vacuum birefringence.
基金supported in part by the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB160203)the National Natural Science Foundation of China(Nos.11875311 and 11421505).
文摘Investigating deuteron–deuteron(DD)fusion reactions in a plasma environment similar to the early stages of the Big Bang is an important topic in nuclear astrophysics.In this study,we experimentally investigated such reactions,using eight laser beams with the third harmonic impacting on a deuterated polyethylene target at the ShenGuang-II Upgrade laser facility.This work focused on the application of range-filter(RF)spectrometers,assembled from a 70 lm aluminum filter and two CR-39 nuclear track detectors,to measure the yields of primary DD-protons.Based on the track diameter calibration results of 3 MeV protons used to diagnose the tracks on the RF spectrometers,an approximate primary DD-proton yield of(8.5±1.7)×10^6 was obtained,consistent with the yields from similar laser facilities worldwide.This indicates that the RF spectrometer is an effective way to measure primary DD-protons.However,due to the low yields of D^3He-protons and its small track diameter,CR-39 detectors were unable to distinguish it from the background spots.Using other accurate detectors may help to measure these rare events.