BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model ...BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.展开更多
BACKGROUND Magnetic compression anastomosis(MCA)is a simple procedure contributing to a reliable anastomosis.However,digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported.AIM To in...BACKGROUND Magnetic compression anastomosis(MCA)is a simple procedure contributing to a reliable anastomosis.However,digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported.AIM To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs.METHODS Sixteen beagles were randomly divided into an MCA group(study group,n=8)and a manual-suture anastomosis group(control group,n=8).Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses.Both devices included a pair of circular daughter and parent magnets each.The time of esophagojejunostomy and jejunojejunostomy,postoperative complications,and survival rate of the two groups were compared.The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained.Healing was observed by the naked eye and a light microscope.RESULTS Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups(survival rate=100%).In the study group,esophagojejunal and jejunojejunal anastomoses took 6.13±0.58 and 4.06±0.42 min,respectively,significantly lower than those in the control group(15.63±1.53 min,P<0.001 and 10.31±1.07 min,P<0.001,respectively).Complications such as bleeding,anastomotic leakage,and anastomotic stenosis were not observed.In the study group,the magnets did not interfere with each other.Discharge time of the jejunojejunal magnetic anastomosis device was 10.75±1.28 d,while that of the esophagojejunal magnetic anastomosis device was 12.25±1.49 d.Residual silk was found in the control group.The study group showed a greater smoothness of the anastomosis than that of the control group.All layers of anastomosis healed well in both groups.CONCLUSION MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.展开更多
BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a def...BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a deformable self-assembled magnetic anastomosis ring(DSAMAR)for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments.METHODS The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles.The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR.The anastomotic specimen,obtained 2 wk after the operation,was observed by both the naked eye and a light microscope.RESULTS The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus.The DSAMAR of seven dogs was successfully transformed into rings,while that of the remaining dog was removed after the first deformation failed.The rings were successfully retransformed after optimization.All animals underwent colonic anastomosis using the DSAMAR.No device-related or procedure-related adverse events were observed.The colostomy specimens of the experimental dogs were obtained 2 wk after the operation.Both gross and histological observations showed good anastomotic healing.CONCLUSION The DSAMAR is a safe and feasible option for the treatment of colon stenosis.Its specific deformation and selfassembly capability maximize the applicability of the minimally invasive treatment.展开更多
BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy.We designed a novel Y-Z magnetic hepatic portal blocking band(Y-Z MHPBB)based on the principle of...BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy.We designed a novel Y-Z magnetic hepatic portal blocking band(Y-Z MHPBB)based on the principle of magnetic compression technique.AIM To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs.METHODS Ten beagles were randomly divided into the experimental group and control group.The operation time,intraoperative blood loss,the number of portal blood flow occlusions,the total time spent on adjusting the blocking band,and the average time spent on adjusting the blocking band were recorded.The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices.RESULTS Laparoscopic hepatectomy was successfully performed in both the experimental group and control group.There was no statistical difference between the two groups in the operation time,intraoperative blood loss,and the number of hepatic portal blood flow occlusions.With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band,the experimental group showed significantly better outcomes than the control group,with a statistical difference(P<0.05).The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility.CONCLUSION The Y-Z MHPBB seems to be an ingenious design,accurate blood flow occlusion effect,and good flexibility;and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.展开更多
基金Supported by the Key Research&Development Program of Shaanxi Province of China,No.2024SF-YBXM-447Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07+1 种基金Fundamental Research Funds for the Central Universities,No.xzy022023068Natural Science Foundation of Shaanxi Province,No.2023-JC-QN-0814.
文摘BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.
基金the Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07(to Yan XP)Key Research and Development Plan of Shaanxi Province,No.2021GXLH-Z-009(to Li Y).
文摘BACKGROUND Magnetic compression anastomosis(MCA)is a simple procedure contributing to a reliable anastomosis.However,digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported.AIM To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs.METHODS Sixteen beagles were randomly divided into an MCA group(study group,n=8)and a manual-suture anastomosis group(control group,n=8).Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses.Both devices included a pair of circular daughter and parent magnets each.The time of esophagojejunostomy and jejunojejunostomy,postoperative complications,and survival rate of the two groups were compared.The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained.Healing was observed by the naked eye and a light microscope.RESULTS Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups(survival rate=100%).In the study group,esophagojejunal and jejunojejunal anastomoses took 6.13±0.58 and 4.06±0.42 min,respectively,significantly lower than those in the control group(15.63±1.53 min,P<0.001 and 10.31±1.07 min,P<0.001,respectively).Complications such as bleeding,anastomotic leakage,and anastomotic stenosis were not observed.In the study group,the magnets did not interfere with each other.Discharge time of the jejunojejunal magnetic anastomosis device was 10.75±1.28 d,while that of the esophagojejunal magnetic anastomosis device was 12.25±1.49 d.Residual silk was found in the control group.The study group showed a greater smoothness of the anastomosis than that of the control group.All layers of anastomosis healed well in both groups.CONCLUSION MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.
基金the Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07the Key Research&Development Program-Social Development of Shaanxi Province of China,No.2023-YBSF-247.
文摘BACKGROUND Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis,there is no report on a single-approach operation using the natural orifice.AIM To design a deformable self-assembled magnetic anastomosis ring(DSAMAR)for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments.METHODS The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles.The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR.The anastomotic specimen,obtained 2 wk after the operation,was observed by both the naked eye and a light microscope.RESULTS The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus.The DSAMAR of seven dogs was successfully transformed into rings,while that of the remaining dog was removed after the first deformation failed.The rings were successfully retransformed after optimization.All animals underwent colonic anastomosis using the DSAMAR.No device-related or procedure-related adverse events were observed.The colostomy specimens of the experimental dogs were obtained 2 wk after the operation.Both gross and histological observations showed good anastomotic healing.CONCLUSION The DSAMAR is a safe and feasible option for the treatment of colon stenosis.Its specific deformation and selfassembly capability maximize the applicability of the minimally invasive treatment.
基金Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University(to Yan XP),No.2022MS-07。
文摘BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy.We designed a novel Y-Z magnetic hepatic portal blocking band(Y-Z MHPBB)based on the principle of magnetic compression technique.AIM To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs.METHODS Ten beagles were randomly divided into the experimental group and control group.The operation time,intraoperative blood loss,the number of portal blood flow occlusions,the total time spent on adjusting the blocking band,and the average time spent on adjusting the blocking band were recorded.The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices.RESULTS Laparoscopic hepatectomy was successfully performed in both the experimental group and control group.There was no statistical difference between the two groups in the operation time,intraoperative blood loss,and the number of hepatic portal blood flow occlusions.With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band,the experimental group showed significantly better outcomes than the control group,with a statistical difference(P<0.05).The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility.CONCLUSION The Y-Z MHPBB seems to be an ingenious design,accurate blood flow occlusion effect,and good flexibility;and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.