Edge detection is an effective method for image segmentation and feature extraction.Therefore,extracting weak edges with the inhomogeneous gray of Corona Virus Disease 2019(COVID-19)CT images is extremely important.Mu...Edge detection is an effective method for image segmentation and feature extraction.Therefore,extracting weak edges with the inhomogeneous gray of Corona Virus Disease 2019(COVID-19)CT images is extremely important.Multiscale morphology has been widely used in the edge detection of medical images due to its excellent boundary detection accuracy.In this paper,we propose a weak edge detection method based on Gaussian filtering and singlescale Retinex(GF_SSR),and improved multiscale morphology and adaptive threshold binarization(IMSM_ATB).As all the CT images have noise,we propose to remove image noise by Gaussian filtering.The edge of CT images is enhanced using the SSR algorithm.In addition,based on the extracted edge of CT images using improved Multiscale morphology,a particle swarm optimization(PSO)algorithm is introduced to binarize the image by automatically getting the optimal threshold.To evaluate our method,we use images from three datasets,namely COVID-19,Kaggle-COVID-19,and COVID-Chestxray,respectively.The average values of results are worthy of reference,with the Shannon information entropy of 1.8539,the Precision of 0.9992,the Recall of 0.8224,the F-Score of 1.9158,running time of 11.3000.Finally,three types of lesion images in the COVID-19 dataset are selected to evaluate the visual effects of the proposed algorithm.Compared with the other four algorithms,the proposed algorithm effectively detects the weak edge of the lesion and provides help for image segmentation and feature extraction.展开更多
With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the sh...With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the short circuit current. For the power grid that short circuit current level closes to the interrupting capacity of circuit breaker, it’s necessary to fully consider all kinds of influence factors, careful checking, so as to obtain more accurate calculation results of short circuit current. In 2018, two ±800 kV high-power Ultra High Voltage Direct Current (UHVDC) transmission projects will be connected with Shaanxi power grid, accompanied by a lot of concomitant fossil-fuel generating plants as power resource, and also a large number of new energy source, includes wind power generation and photovoltaic power generation. Around one of the UHVDC converter stations, short circuit current may exceed the withstand limit of some certain circuit breakers. In order to get more accurate short circuit current calculation results, three measures are used: 1) contrastive calculation and analysis by algorithm based on schemes and algorithm based on power flow;2) analysis the influence of UHVDC by electromagnetic transient and electromechanical transient hybrid simulation;3) considered a detailed model of Doubly Fed Induction Generator (DFIG) with low voltage ride through characteristics. The calculation results shows that: in the typical operation mode of Shaanxi power grid of 2018, the original calculation results by conventional calculation method are coincident with the results by considering the influence of algorithms, UHVDC and DFIG in large, in which: the results of the algorithm based on power flow are smaller than that of the algorithm based on schemes about 2 - 8 kA;the steady values of the short circuit current provided by UHVDC converterstation (includes rectifiers and smoothing capacitors) are about 0 - 3 kA;the steady values of the short circuit current provided by DFIG are about 0 - 5 kA. The calculation results can provide reference for the selection of the circuit breaker, and it can be verified by fault recording data in the future.展开更多
基金Research on the Application of MR Technology in the Teaching of Emergency Nursing Training(HBKC217154).
文摘Edge detection is an effective method for image segmentation and feature extraction.Therefore,extracting weak edges with the inhomogeneous gray of Corona Virus Disease 2019(COVID-19)CT images is extremely important.Multiscale morphology has been widely used in the edge detection of medical images due to its excellent boundary detection accuracy.In this paper,we propose a weak edge detection method based on Gaussian filtering and singlescale Retinex(GF_SSR),and improved multiscale morphology and adaptive threshold binarization(IMSM_ATB).As all the CT images have noise,we propose to remove image noise by Gaussian filtering.The edge of CT images is enhanced using the SSR algorithm.In addition,based on the extracted edge of CT images using improved Multiscale morphology,a particle swarm optimization(PSO)algorithm is introduced to binarize the image by automatically getting the optimal threshold.To evaluate our method,we use images from three datasets,namely COVID-19,Kaggle-COVID-19,and COVID-Chestxray,respectively.The average values of results are worthy of reference,with the Shannon information entropy of 1.8539,the Precision of 0.9992,the Recall of 0.8224,the F-Score of 1.9158,running time of 11.3000.Finally,three types of lesion images in the COVID-19 dataset are selected to evaluate the visual effects of the proposed algorithm.Compared with the other four algorithms,the proposed algorithm effectively detects the weak edge of the lesion and provides help for image segmentation and feature extraction.
文摘With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the short circuit current. For the power grid that short circuit current level closes to the interrupting capacity of circuit breaker, it’s necessary to fully consider all kinds of influence factors, careful checking, so as to obtain more accurate calculation results of short circuit current. In 2018, two ±800 kV high-power Ultra High Voltage Direct Current (UHVDC) transmission projects will be connected with Shaanxi power grid, accompanied by a lot of concomitant fossil-fuel generating plants as power resource, and also a large number of new energy source, includes wind power generation and photovoltaic power generation. Around one of the UHVDC converter stations, short circuit current may exceed the withstand limit of some certain circuit breakers. In order to get more accurate short circuit current calculation results, three measures are used: 1) contrastive calculation and analysis by algorithm based on schemes and algorithm based on power flow;2) analysis the influence of UHVDC by electromagnetic transient and electromechanical transient hybrid simulation;3) considered a detailed model of Doubly Fed Induction Generator (DFIG) with low voltage ride through characteristics. The calculation results shows that: in the typical operation mode of Shaanxi power grid of 2018, the original calculation results by conventional calculation method are coincident with the results by considering the influence of algorithms, UHVDC and DFIG in large, in which: the results of the algorithm based on power flow are smaller than that of the algorithm based on schemes about 2 - 8 kA;the steady values of the short circuit current provided by UHVDC converterstation (includes rectifiers and smoothing capacitors) are about 0 - 3 kA;the steady values of the short circuit current provided by DFIG are about 0 - 5 kA. The calculation results can provide reference for the selection of the circuit breaker, and it can be verified by fault recording data in the future.