The mechanical properties of modified sea water sea sand coral concrete(SWSSCC)under axial compression were experimentally studied.Two different parameters were considered in this test:types of cement and fiber.An exp...The mechanical properties of modified sea water sea sand coral concrete(SWSSCC)under axial compression were experimentally studied.Two different parameters were considered in this test:types of cement and fiber.An experimental campaign was developed involving uniaxial compression tests and the use of digital image correlation(DIC)method to analyze the strain distribution and crack propagation of specimen.Test results indicated that the compressive strength and elastic modulus of SWSSCC were improved by adding stainless steel fibers(SSF),while polypropylene fibers(PF)enhanced the SWSSCC peak deformation.It was found that the elastic modulus and strength of SWSSCC using ordinary Portland cement(OPC)were higher compared to specimen with low alkalinity sulphoaluminate cement(LAS).Typical strain distribution changed with the variation of fiber types.The propagation and characteristics of cracks in SWSSCC containing PF were similar to those of cracks in SWSSCC.However,the propagation of cracks and the development of plastic deformation in SWSSCC were effectively hindered by adopting SSF.Finally,an analytical stress-strain expression of specimen considering the influences of fibers was established.The obtained results would provide a basis for the application of SWSSCC.展开更多
Chloride attack on concrete structures is affected by the complex stress state inside concrete,and the effect of recycled aggregates renders this process more complex.Enhancing the chloride resistance of recycled conc...Chloride attack on concrete structures is affected by the complex stress state inside concrete,and the effect of recycled aggregates renders this process more complex.Enhancing the chloride resistance of recycled concrete in a complex environment via carbonization facilitates the popularization and application of recycled concrete and alleviates the greenhouse effect.In this study,the chloride ion diffusion and deformation properties of recycled concrete after carbonization are investigated using a chloride salt load-coupling device.The results obtained demonstrate that the chloride ion diffusivity of recycled concrete first decreases and then increases as the compressive load increases,which is consistent with the behavior of concrete,in that it first undergoes compressive deformation,followed by crack propagation.Carbonation enhances the performance of the recycled aggregates and reduces their porosity,thereby reducing the chloride diffusion coefficient of the recycled concrete under different compressive load combinations.The variation in the chloride ion diffusivity of the carbonized recycled aggregate concrete with the load is consistent with a theoretical formula.展开更多
The purpose of this study is to reveal the service performance of recycled aggregate concrete(RAC)components for different values of water-cement ratio and replacement rate of recycled coarse aggregate(RCA).Generally,...The purpose of this study is to reveal the service performance of recycled aggregate concrete(RAC)components for different values of water-cement ratio and replacement rate of recycled coarse aggregate(RCA).Generally,the concrete strength decreases with the increase of the replacement rate of RCA,in order to meet the strength requirements when changing the replacement rate of RCA,it is necessary to change the water-cement ratio at the same time.Therefore,the axial compressive strengths of prism with 25 mix proportions,the short-term mechanical properties and long-term deformation properties of reinforced concrete beams were tested respectively by changing water-cement ratio and RCA replacement rate.The bearing capacity and the strain nephogram of samples under different loads were obtained using the Digital Image Correlation(DIC)method,and a self-made gravity loading experimental device was used for long-term deformation investigation.Results showed that the damage pattern of RAC was the same as that of natural aggregate concrete(NAC),but the brittleness was more pronounced.The brittleness of concrete before failure can be reduced more effectively by adjusting the replacement rate of RCA than by adjusting the water-cement ratio.The water-cement ratio has an evident influence on the axial compressive strength and early creep of concrete,while the replacement rate of RCA has a remarkable effect on the long-term deformation of the concrete beams.展开更多
基金supported by the National Natural Science Foundation of China(Nos.51408346,51978389)the China Postdoctoral Science Foundation Funded Project(No.2015M572584,No.2016T0914)+3 种基金the Shandong Provincial Natural Science Foundation(No.ZR2019PEE044)the Opening Foundation of Shandong Key Laboratory of Civil Engineering Disaster Prevention and Mitigation(CDPM2019KF12)the Systematic Project of Guangxi Key Laboratory of Disaster Prevention and Structural Safety(2019ZDK035)the Shandong University of Science and Technology(SDKDYC190358).
文摘The mechanical properties of modified sea water sea sand coral concrete(SWSSCC)under axial compression were experimentally studied.Two different parameters were considered in this test:types of cement and fiber.An experimental campaign was developed involving uniaxial compression tests and the use of digital image correlation(DIC)method to analyze the strain distribution and crack propagation of specimen.Test results indicated that the compressive strength and elastic modulus of SWSSCC were improved by adding stainless steel fibers(SSF),while polypropylene fibers(PF)enhanced the SWSSCC peak deformation.It was found that the elastic modulus and strength of SWSSCC using ordinary Portland cement(OPC)were higher compared to specimen with low alkalinity sulphoaluminate cement(LAS).Typical strain distribution changed with the variation of fiber types.The propagation and characteristics of cracks in SWSSCC containing PF were similar to those of cracks in SWSSCC.However,the propagation of cracks and the development of plastic deformation in SWSSCC were effectively hindered by adopting SSF.Finally,an analytical stress-strain expression of specimen considering the influences of fibers was established.The obtained results would provide a basis for the application of SWSSCC.
基金sponsored by the National Natural Science Foundation of China(Grant Nos.52168015 and 51768005)the Natural Science Foundation of Guangxi(No.2018GXNSFAA281333)the Interdisciplinary Scientific Research Foundation of Guangxi University(No.202200227).
文摘Chloride attack on concrete structures is affected by the complex stress state inside concrete,and the effect of recycled aggregates renders this process more complex.Enhancing the chloride resistance of recycled concrete in a complex environment via carbonization facilitates the popularization and application of recycled concrete and alleviates the greenhouse effect.In this study,the chloride ion diffusion and deformation properties of recycled concrete after carbonization are investigated using a chloride salt load-coupling device.The results obtained demonstrate that the chloride ion diffusivity of recycled concrete first decreases and then increases as the compressive load increases,which is consistent with the behavior of concrete,in that it first undergoes compressive deformation,followed by crack propagation.Carbonation enhances the performance of the recycled aggregates and reduces their porosity,thereby reducing the chloride diffusion coefficient of the recycled concrete under different compressive load combinations.The variation in the chloride ion diffusivity of the carbonized recycled aggregate concrete with the load is consistent with a theoretical formula.
基金the National Natural Science Foundation of China(Grant Nos.52168015,51768005)Natural Science Foundation of Guangxi Province(No.2018GXNSFAA281333).
文摘The purpose of this study is to reveal the service performance of recycled aggregate concrete(RAC)components for different values of water-cement ratio and replacement rate of recycled coarse aggregate(RCA).Generally,the concrete strength decreases with the increase of the replacement rate of RCA,in order to meet the strength requirements when changing the replacement rate of RCA,it is necessary to change the water-cement ratio at the same time.Therefore,the axial compressive strengths of prism with 25 mix proportions,the short-term mechanical properties and long-term deformation properties of reinforced concrete beams were tested respectively by changing water-cement ratio and RCA replacement rate.The bearing capacity and the strain nephogram of samples under different loads were obtained using the Digital Image Correlation(DIC)method,and a self-made gravity loading experimental device was used for long-term deformation investigation.Results showed that the damage pattern of RAC was the same as that of natural aggregate concrete(NAC),but the brittleness was more pronounced.The brittleness of concrete before failure can be reduced more effectively by adjusting the replacement rate of RCA than by adjusting the water-cement ratio.The water-cement ratio has an evident influence on the axial compressive strength and early creep of concrete,while the replacement rate of RCA has a remarkable effect on the long-term deformation of the concrete beams.