Coating the hydroxyapatite (HA) on the titanium alloy surface can obtain a bioactive implant with high mechanical properties However, the bonding force between the titanium alloy and the HA was low due to their diff...Coating the hydroxyapatite (HA) on the titanium alloy surface can obtain a bioactive implant with high mechanical properties However, the bonding force between the titanium alloy and the HA was low due to their different coefficient of thermal expansion (CET). Preparing the multi-layer coating with alleviated thermal stress on titanium alloy substrate is few reported. Fabrication of a TiO2-bioactive glass (BG)-HA bioactive coating was proposed to solve this problem. A particular TiO2 surface was prepared on the titanium alloy substrate by micro-arc oxidation treatment. The BG and HA coating were coated onto the TiO2 surface in turn by using a sol-gel method. The microstructure, surface morphology and phase composition of the coatings were analyzed. The bonding force of coatings was investigated by the nick apparatus. In vitro dissolution was performed by soaking the TiO2-BG-HA coated samples into the simulated body fluid for various periods. Micro-structural observations indicated that no delamination and crack occurred at the interface of HA/BG and BG/TiO2. The bonding between the substrate and coating consists of the mechanical interaction and the chemical bonding. The bonding force could reach about 45 N. The TiO2-BG-HA coating displayed the excellent forming ability of bone-like apatite when it was soaked into the simulated body fluid. This work suggests an innovative way to reduce the internal stress among coatings through varying BG composition to adjust its CTE, so as to enhance the bonding force.展开更多
China’s High-speed steel cutting tools hold a considerable share in the global market. However, the overproduction of low-end HSS tools causes serious resource waste and low efficiency, which has become one of the ma...China’s High-speed steel cutting tools hold a considerable share in the global market. However, the overproduction of low-end HSS tools causes serious resource waste and low efficiency, which has become one of the major problems in the tool industry in China. So a new Surface Modification technology is developed, which can make the low-end HSS tools into the high-end ones. On the analysis of the mechanism of cryogenic and quenching-polish-quenching(QPQ), the cryogenic and QPQ compound treatment are studied by using ?8 HSS(M2) drills. The nitriding layer and the base of the drill bit are Studied and analyzed, and the mechanism of compound treatment is discussed by the technological parameters adjustment and the combination test of cryogenic, nitrogen, tempering procedures, and several analysis methods such as the optics metallographic microscope, the scanning electronic microscope (SEM), X-ray diffraction and micro hardness. The cutting test is done on the drills by cryogenic treatment, QPQ treatment and cryogenic and QPQ compound treatment separately. The results indicates that the cutting life of HSS (M2) drill can be increased dramatically by cryogenic and QPQ compound treatment.展开更多
基金supported by National Natural Science Foundation of China (Grant No.50872110)
文摘Coating the hydroxyapatite (HA) on the titanium alloy surface can obtain a bioactive implant with high mechanical properties However, the bonding force between the titanium alloy and the HA was low due to their different coefficient of thermal expansion (CET). Preparing the multi-layer coating with alleviated thermal stress on titanium alloy substrate is few reported. Fabrication of a TiO2-bioactive glass (BG)-HA bioactive coating was proposed to solve this problem. A particular TiO2 surface was prepared on the titanium alloy substrate by micro-arc oxidation treatment. The BG and HA coating were coated onto the TiO2 surface in turn by using a sol-gel method. The microstructure, surface morphology and phase composition of the coatings were analyzed. The bonding force of coatings was investigated by the nick apparatus. In vitro dissolution was performed by soaking the TiO2-BG-HA coated samples into the simulated body fluid for various periods. Micro-structural observations indicated that no delamination and crack occurred at the interface of HA/BG and BG/TiO2. The bonding between the substrate and coating consists of the mechanical interaction and the chemical bonding. The bonding force could reach about 45 N. The TiO2-BG-HA coating displayed the excellent forming ability of bone-like apatite when it was soaked into the simulated body fluid. This work suggests an innovative way to reduce the internal stress among coatings through varying BG composition to adjust its CTE, so as to enhance the bonding force.
基金supported by the fund of Sichuan Provincial Key Laboratory of Special Material and Preparative Technique of China (Xihua University)
文摘China’s High-speed steel cutting tools hold a considerable share in the global market. However, the overproduction of low-end HSS tools causes serious resource waste and low efficiency, which has become one of the major problems in the tool industry in China. So a new Surface Modification technology is developed, which can make the low-end HSS tools into the high-end ones. On the analysis of the mechanism of cryogenic and quenching-polish-quenching(QPQ), the cryogenic and QPQ compound treatment are studied by using ?8 HSS(M2) drills. The nitriding layer and the base of the drill bit are Studied and analyzed, and the mechanism of compound treatment is discussed by the technological parameters adjustment and the combination test of cryogenic, nitrogen, tempering procedures, and several analysis methods such as the optics metallographic microscope, the scanning electronic microscope (SEM), X-ray diffraction and micro hardness. The cutting test is done on the drills by cryogenic treatment, QPQ treatment and cryogenic and QPQ compound treatment separately. The results indicates that the cutting life of HSS (M2) drill can be increased dramatically by cryogenic and QPQ compound treatment.