We developed a novel two-photon polymerization(2PP)configuration for fabrication of high-aspect three-dimensional(3D)structures,with an overall height larger than working distance of the microscope objective used for ...We developed a novel two-photon polymerization(2PP)configuration for fabrication of high-aspect three-dimensional(3D)structures,with an overall height larger than working distance of the microscope objective used for laser beam focusing into a photosensitive material.This method is based on a modified optical 2PP setup,where a microscope objective(1003 high N.A.),immersion oil and cover glass can be moved together into the photosensitive material,resulting in an effective higher and wider objective working range(WOW-2PP).The proposed technique enables the fabrication of high-aspect structures with sub-micrometer process resolution.3D structures with a height of 7 mm are demonstrated,which could hardly be built with the conventional 2PP set-up due to refractive index mismatch and laser beam disturbances.展开更多
The purpose of the study is to reconstruct the coronary arteries in 3 dimension (3D) from serial intravascular ultrasound (IVUS) images generated during a pullback of IVUS catheter. Slowly pullback. real-time, cross-s...The purpose of the study is to reconstruct the coronary arteries in 3 dimension (3D) from serial intravascular ultrasound (IVUS) images generated during a pullback of IVUS catheter. Slowly pullback. real-time, cross-sectional IVUS images of 18 patients (2 with normal coronary arteries. 1 with coronary aneurysm. and 15 post PTCA) were obtained by using a 20 MHz. 3.5F IVUS catheter and recorded on video tape. A series of 90-frame consecutive IVUS images were digitized into a SUN Spare 11 workstation. Digitized data were reconstructed to 3D images with use of voxel space modeling and were generated in both sagittal and cylindrical formats. The sagittal format results in a longitudinal展开更多
We have shown the value of intravascular ultrasound (IVUS) in the evaluation of myocardial bridging (MB). The purpose of the study was to elucidate the mechanism of inter-
基金This work was supported by the Deutsche Forschungsgemeinschaft(German Research Foundation)Cluster of Excellence REBIRTH and EU/FP7 project Phocam.We thank E Fadeeva and J Koch for helpful technical discussions.
文摘We developed a novel two-photon polymerization(2PP)configuration for fabrication of high-aspect three-dimensional(3D)structures,with an overall height larger than working distance of the microscope objective used for laser beam focusing into a photosensitive material.This method is based on a modified optical 2PP setup,where a microscope objective(1003 high N.A.),immersion oil and cover glass can be moved together into the photosensitive material,resulting in an effective higher and wider objective working range(WOW-2PP).The proposed technique enables the fabrication of high-aspect structures with sub-micrometer process resolution.3D structures with a height of 7 mm are demonstrated,which could hardly be built with the conventional 2PP set-up due to refractive index mismatch and laser beam disturbances.
文摘The purpose of the study is to reconstruct the coronary arteries in 3 dimension (3D) from serial intravascular ultrasound (IVUS) images generated during a pullback of IVUS catheter. Slowly pullback. real-time, cross-sectional IVUS images of 18 patients (2 with normal coronary arteries. 1 with coronary aneurysm. and 15 post PTCA) were obtained by using a 20 MHz. 3.5F IVUS catheter and recorded on video tape. A series of 90-frame consecutive IVUS images were digitized into a SUN Spare 11 workstation. Digitized data were reconstructed to 3D images with use of voxel space modeling and were generated in both sagittal and cylindrical formats. The sagittal format results in a longitudinal
文摘We have shown the value of intravascular ultrasound (IVUS) in the evaluation of myocardial bridging (MB). The purpose of the study was to elucidate the mechanism of inter-