The three-pool and first-order model separates the mineralizable organic carbon into active,slow,and passive carbon pools.This paper used the model and decomposition curves of the soil organic carbon to fit the active...The three-pool and first-order model separates the mineralizable organic carbon into active,slow,and passive carbon pools.This paper used the model and decomposition curves of the soil organic carbon to fit the active pool and its decomposition rate,slow pool and its decomposition rate.The results showed that the size of the active pool from different profiles accounted for 2.09%-3.08% of the total soil organic carbon and the mean residue time was 3.57-17.21 days.And the size of the slow pool accounted for 3.19%-43.55% and the mean residue time was 1.12-4.94 years.Acid hydrolysis(6M HCl) was used to fractionate the passive organic carbon,which accounted for 50.83%-94.44% of the total soil organic carbon.展开更多
Herein,a three-dimensional(3D)inversion method in the frequency domain based on a time–frequency transformation was developed to improve the efficiency of the 3D inversion of transient electromagnetic(TEM)data.The Fo...Herein,a three-dimensional(3D)inversion method in the frequency domain based on a time–frequency transformation was developed to improve the efficiency of the 3D inversion of transient electromagnetic(TEM)data.The Fourier transform related to the electromagnetic response in the frequency and time domains becomes a sine or cosine transform under the excitation of downward-step current.We established a transformation matrix based on the digital fi ltering calculation for the sine transform,and then the frequency domain projection of the TEM data was determined from the linear transformation system using the smoothing constrained least squares inversion method,in which only the imaginary part was used to maintain the TEM data transformation equivalence in the bidirectional projection.Thus,the time-domain TEM inversion problem was indirectly and effectively solved in the frequency domain.In the 3D inversion of the transformed frequency-domain data,the limited-memory Broyden–Fletcher–Goldfarb–Shannoquasi–Newton(L-BFGS)method was used and modifi ed with a restart strategy to adjust the regularization parameter when the algorithm tended to a local minimum.Synthetic data tests showed that our domain transformation method can stably project the TEM data into the frequency domain with very high accuracy;furthe rmore,the 3D inversion of the transformed frequency-domain data is stable,can be used to recover the real resistivity model with an acceptable effi ciency.展开更多
基金Supported by the Work Project of China Geological Survey (1212010911062)Guangxi Zhuang Autonomous Region Innovation Project (0842008)National Natural Science Foundation (40872213)
文摘The three-pool and first-order model separates the mineralizable organic carbon into active,slow,and passive carbon pools.This paper used the model and decomposition curves of the soil organic carbon to fit the active pool and its decomposition rate,slow pool and its decomposition rate.The results showed that the size of the active pool from different profiles accounted for 2.09%-3.08% of the total soil organic carbon and the mean residue time was 3.57-17.21 days.And the size of the slow pool accounted for 3.19%-43.55% and the mean residue time was 1.12-4.94 years.Acid hydrolysis(6M HCl) was used to fractionate the passive organic carbon,which accounted for 50.83%-94.44% of the total soil organic carbon.
基金the National Key Research and Development Program of China(No.2016YFC060110403).
文摘Herein,a three-dimensional(3D)inversion method in the frequency domain based on a time–frequency transformation was developed to improve the efficiency of the 3D inversion of transient electromagnetic(TEM)data.The Fourier transform related to the electromagnetic response in the frequency and time domains becomes a sine or cosine transform under the excitation of downward-step current.We established a transformation matrix based on the digital fi ltering calculation for the sine transform,and then the frequency domain projection of the TEM data was determined from the linear transformation system using the smoothing constrained least squares inversion method,in which only the imaginary part was used to maintain the TEM data transformation equivalence in the bidirectional projection.Thus,the time-domain TEM inversion problem was indirectly and effectively solved in the frequency domain.In the 3D inversion of the transformed frequency-domain data,the limited-memory Broyden–Fletcher–Goldfarb–Shannoquasi–Newton(L-BFGS)method was used and modifi ed with a restart strategy to adjust the regularization parameter when the algorithm tended to a local minimum.Synthetic data tests showed that our domain transformation method can stably project the TEM data into the frequency domain with very high accuracy;furthe rmore,the 3D inversion of the transformed frequency-domain data is stable,can be used to recover the real resistivity model with an acceptable effi ciency.