A prompt gamma neutron activation analysis system with a 252Cf neutron source for on-line cement analysis has been simulated with the MCNP code.The results indicate that the optimum arrangement is a Bi shield of 20-mm...A prompt gamma neutron activation analysis system with a 252Cf neutron source for on-line cement analysis has been simulated with the MCNP code.The results indicate that the optimum arrangement is a Bi shield of 20-mm thickness,a polyethylene moderator of 50-mm thickness,a source-to-sample distance of 70 mm,and cement samples of 1200 mm×600 mm×170 mm.To absorb thermal neutrons and suppress low-energy γ-rays,the optimum-sized sheets are 150 mm×7 mm Cd,and 150 mm×15 mm Pb.展开更多
The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the respon...The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation.展开更多
基金Supported by NSFC(40974065)National Innovation Method(2008IM021500)+1 种基金National Key Technology R & D Program(2008BAC44B04)Province Key Technology R & D Program(2008SZ0148,2008GZ0197,2008GZ0040)
文摘A prompt gamma neutron activation analysis system with a 252Cf neutron source for on-line cement analysis has been simulated with the MCNP code.The results indicate that the optimum arrangement is a Bi shield of 20-mm thickness,a polyethylene moderator of 50-mm thickness,a source-to-sample distance of 70 mm,and cement samples of 1200 mm×600 mm×170 mm.To absorb thermal neutrons and suppress low-energy γ-rays,the optimum-sized sheets are 150 mm×7 mm Cd,and 150 mm×15 mm Pb.
文摘The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation.