期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Evaluation of the Functional Impression Technique with Various Impression Materials on the Surface Topography of Dental Stone Casts and Their Effect on Retention
1
作者 manal r. alammari 《Open Journal of Stomatology》 2018年第7期258-270,共13页
Background: The accuracy of the final prosthesis is affected by the final impression technique and master cast production. The aim of the present study was to evaluate the effect of the functional impression technique... Background: The accuracy of the final prosthesis is affected by the final impression technique and master cast production. The aim of the present study was to evaluate the effect of the functional impression technique with various impression materials on the surface characteristic of dental stone casts and their clinical effect on the retention of complete dentures. Method: Specimens of three impression materials/stone casts were fabricated. The specimens of the impression materials/stone casts were divided into three equal groups (I, II, and III). The impression materials used were as follows: tissue conditioner group (I), zinc oxide (ZEO) (group II) and poly (vinyl siloxane) (PVS) (group III). Cylindrical split aluminium moulds were designed to receive the impression materials and the stone mixture. The surface roughness of the stone cast specimens of the three groups (I, II, and III) was measured with a surface profilometer and analyzed by a scanning electron microscope. A clinical study included five severely resorbed mandibular edentulous alveolar ridges and edentulous maxillary arches. Each subject received three heat-cured acrylic resin dentures, fabricated using the functional impression technique. The three dentures were identical except for the different impression materials used from Groups I, II and III. The retentive force of each denture for each subject was measured. Result: The results of this study revealed that the mean value of surface roughness of the stone cast surface of group I was higher than group II and group III. A statistically significant difference was observed in surface roughness and the retentive dislodging force between the three studied groups. Although using a tissue conditioner as a functional impression material led to a high level of surface roughness and good retention, it could not produce the same smooth surface quality of PVS or ZEO. These data were supported by SEM analysis. The complete dentures for these patients require important oral and denture hygiene care. Conclusion: Complete dentures made using functional impression technique with PVC as a final impression material are more comfortable, retentive and stable. 展开更多
关键词 IMPRESSION Techniques IMPRESSION Materials Surface ROUGHNESS Scanning Electron MICROSCOPE and Retention of Complete DENTURE
下载PDF
A novel bio-sensor for registration of biting force in occlusally reactive single mandibular implant overdenture
2
作者 Fahad H. Banasr manal r. alammari 《Open Journal of Stomatology》 2013年第7期370-378,共9页
Mandibular single denture opposed by maxillary natural dentition showed a great problem. However, mandibular implant overdenture treatment has gained considerable recognition. Ten male patients with complete mandibula... Mandibular single denture opposed by maxillary natural dentition showed a great problem. However, mandibular implant overdenture treatment has gained considerable recognition. Ten male patients with complete mandibular edentulous arch and opposing arch have full natural dentition. Patients were divided into two groups. All patients received two endosseous titanium implants. In Group I, patients were rehabilitated with conventional implant retained overdentures. While in Group II, Patients were rehabilitated with occlusal reactive implant overdentures. A Novel proposed biosensor was used to measure the amount of biting force on the implant retained overdenture. Quantitative electromyographic (EMG) signals of the masseter and anterior fibers of temporalis muscles were recorded, filtered and directly interfaced with a computer to represent the data graphically. The mean amplitude (μV), turn, and activity were recorded at the baseline and after three months. The results revealed an increase in the muscle activity in group II after three months as compared to group I. Significant difference in bilateral biting force at the premolar-molar area was found between group I and group II after three months. This study concluded that a resilient implant overdenture denture could be a desirable treatment in mandibular overdenture supported by two implants with resilient attachment and opposing natural dentition due to its easy fabrication and durability in use and increased muscle activity. 展开更多
关键词 Bio-Sensor BITING Force MANDIBULAR IMPLANT Resilient OVERDENTURE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部