Analysis of the Cooling Water Temperature Rise of Accelerating Electrodes in EAST Neutral Beam Injector Beam Extraction 被引量:3
1
作者 XU Yong-Jian HU Chun-Dong +5 位作者 XIE Yuan-Lai LI Jun LIU Sheng XIE Ya-Hong YU Ling nbi group 《Chinese Physics Letters》 SCIE CAS CSCD 2013年第3期44-46,共3页
Neutral beam injection is recognized as one of the most effective means of plasma heating.The preliminary data of beam power deposition in different electrodes during beam extraction are obtained on the EAST neutral b... Neutral beam injection is recognized as one of the most effective means of plasma heating.The preliminary data of beam power deposition in different electrodes during beam extraction are obtained on the EAST neutral beam injector test stand.The measurement of the cooling water temperature rise of accelerating electrodes is reported.The data given can guide the optimization of beam extraction parameters and decrease the damage to the accelerating electrodes following long pulse beam extraction. 展开更多
关键词 INJECTION DAMAGE NEUTRAL
原文传递
Analysis of the Pipe Heat Loss of the Water Flow Calorimetry System in EAST Neutral Beam Injector
2
作者 HU Chundong CHEN Yu +4 位作者 XU Yongjian YU Ling LI Xiang ZHANG Weitang nbi group 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第11期1139-1142,共4页
Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the... Neutral beam injection heating is one of the main auxiliary heating methods in controllable nuclear fusion research. In the EAST neutral beam injector, a water flow calorimetry (WFC) system is applied to measure the heat load on the electrode system of the ion source and the heat loading components of the beamline. Due to the heat loss in the return water pipe, there are some measuring errors for the current WFC system. In this paper, the errors were measured experimentally and analyzed theoretically, which lay a basis for the exact calculation of beam power deposition distribution and neutralization efficiency. 展开更多
关键词 water flow calorimetry power deposition neutral beam injection heat loss