Inhibiting the death receptor 3(DR3)signaling pathway in group 3 innate lymphoid cells(ILC3s)presents a promising approach for promoting mucosal repair in individuals with ulcerative colitis(UC).Paeoniflorin,a promine...Inhibiting the death receptor 3(DR3)signaling pathway in group 3 innate lymphoid cells(ILC3s)presents a promising approach for promoting mucosal repair in individuals with ulcerative colitis(UC).Paeoniflorin,a prominent component of Paeonia lactiflora Pall.,has demonstrated the ability to restore barrier function in UC mice,but the precise mechanism remains unclear.In this study,we aimed to delve into whether paeoniflorin may promote intestinal mucosal repair in chronic colitis by inhibiting DR3 signaling in ILC3s.C57BL/6 mice were subjected to random allocation into 7 distinct groups,namely the control group,the 2%dextran sodium sulfate(DSS)group,the paeoniflorin groups(25,50,and 100 mg/kg),the anti-tumor necrosis factor-like ligand 1A(anti-TL1A)antibody group,and the IgG group.We detected the expression of DR3 signaling pathway proteins and the proportion of ILC3s in the mouse colon using Western blot and flow cytometry,respectively.Meanwhile,DR3-overexpressing MNK-3 cells and 2%DSS-induced Rag1^(-/-)mice were used for verification.The results showed that paeoniflorin alleviated DSS-induced chronic colitis and repaired the intestinal mucosal barrier.Simultaneously,paeoniflorin inhibited the DR3 signaling pathway in ILC3s and regulated the content of cytokines(interleukin-17A,granulocyte-macrophage colony stimulating factor,and interleukin-22).Alternatively,paeoniflorin directly inhibited the DR3 signaling pathway in ILC3s to repair mucosal damage independently of the adaptive immune system.We additionally confirmed that paeoniflorin-conditioned medium(CM)restored the expression of tight junctions in Caco-2 cells via coculture.In conclusion,paeoniflorin ameliorates chronic colitis by enhancing the intestinal barrier in an ILC3-dependent manner,and its mechanism is associated with the inhibition of the DR3 signaling pathway.展开更多
It has been well identified that the extreme events significantly impact the system operation. In this work, a comprehensive operating strategy, which coordinates the preventive strategies and system restoration, was ...It has been well identified that the extreme events significantly impact the system operation. In this work, a comprehensive operating strategy, which coordinates the preventive strategies and system restoration, was proposed. A re-dispatch model that limits the potential loss under extreme events, as well as provides adequate resources for system restoration after the extreme events, was proposed. An optimal power flow based method was established to solve the proposed model. The availabilities of components and the remaining system due to the extreme events were restored by extending the EPRI’s System Restoration Navigator (SRN) with a little modification. Case studies demonstrate the proposed model and methods.展开更多
In recent years, sub-synchronous oscillation accidents caused by wind power integration have received extensive attention. The recorded constant-amplitude waveforms can be induced by either linear or nonlinear oscilla...In recent years, sub-synchronous oscillation accidents caused by wind power integration have received extensive attention. The recorded constant-amplitude waveforms can be induced by either linear or nonlinear oscillation mechanisms. Hence, the nonlinear behavior needs to be distinguished prior to choosing the analysis method. Since the 1960s, the higher-order statistics(HOS) theory has become a powerful tool for the detection of nonlinear behavior(DNB) in production quality control wherein it has mainly been applied to mechanical condition monitoring and fault diagnosis. This study focuses on the hard limiters of the voltage source converter(VSC) control systems in the wind farms and attempts to detect the nonlinear behavior caused by bi-or uni-lateral saturation hard limiting using the HOS analysis. First, the conventional describing function is extended to obtain the detailed frequency domain information on the bi-and uni-lateral saturation hard limiting. Furthermore, the bi-and tri-spectra are introduced as the HOS, which are extended into bi-and tri-coherence spectra to eliminate the effects of the linear parts on the harmonic characteristics of hard limiting in the VSC control system, respectively. The effectiveness of the HOS in the DNB and the classification of the hard-limiting types is proven, and its detailed derivation and estimation procedure is presented. Finally, the quadratic and cubic phase coupling in the signals is illustrated, and the performance of the proposed method is evaluated and discussed.展开更多
The oscillation phenomena associated with the control of voltage source converters(VSCs)are concerning,making it crucial to locate the sources of such oscillations and suppress the oscillations.Therefore,this paper pr...The oscillation phenomena associated with the control of voltage source converters(VSCs)are concerning,making it crucial to locate the sources of such oscillations and suppress the oscillations.Therefore,this paper presents a location scheme based on the energy structure and nonlinearity detection.The energy structure,which conforms to the principle of the energy-based method and dissipativity theory,is developed to describe the transient energy flow for VSCs,based on which a defined characteristic quantity is implemented to narrow the scope for locating the sources of oscillations.Moreover,based on the self-sustained oscillation characteristics of VsCs,an index for nonlinearity detection is applied to locate the VSCs that produce the oscillation energy.The combination of the energy structure and nonlinearity detection distinguishes the contribu-tions of different VSCs to the oscillation.The results of a case study implemented by the PSCAD/EMTDC simulation validate theproposed scheme.展开更多
With the rapid development of artificial intelligence(AI),it is foreseeable that the accuracy and efficiency of dynamic analysis for future power system will be greatly improved by the integration of dynamic simulator...With the rapid development of artificial intelligence(AI),it is foreseeable that the accuracy and efficiency of dynamic analysis for future power system will be greatly improved by the integration of dynamic simulators and AI.To explore the interaction mechanism of power system dynamic simulations and AI,a general design for AI-oriented power system dynamic simulators is proposed,which consists of a high-performance simulator with neural network supportability and flexible external and internal application programming interfaces(APIs).With the support of APIs,simulation-assisted AI and AIassisted simulation form a comprehensive interaction mechanism between power system dynamic simulations and AI.A prototype of this design is implemented and made public based on a highly efficient electromechanical simulator.Tests of this prototype are carried out in four scenarios including sample generation,AI-based stability prediction,data-driven dynamic component modeling,and AI-aided stability control,which prove the validity,flexibility,and efficiency of the design and implementation for AI-oriented power system dynamic simulators.展开更多
This paper employs an efficacious analytical tool,adaptive simplified human learning optimization(ASHLO)algorithm,to solve optimal power flow(OPF)problem in AC/DC hybrid power system,considering valve-point loading ef...This paper employs an efficacious analytical tool,adaptive simplified human learning optimization(ASHLO)algorithm,to solve optimal power flow(OPF)problem in AC/DC hybrid power system,considering valve-point loading effects of generators,carbon tax,and prohibited operating zones of generators,respectively.ASHLO algorithm,involves random learning operator,individual learning operator,social learning operator and adaptive strategies.To compare and analyze the computation performance of the ASHLO method,the proposed ASHLO method and other heuristic intelligent optimization methods are employed to solve OPF problem on the modified IEEE 30-bus and 118-bus AC/DC hybrid test system.Numerical results indicate that the ASHLO method has good convergent property and robustness.Meanwhile,the impacts of wind speeds and locations of HVDC transmission line integrated into the AC network on the OPF results are systematically analyzed.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.:82074092),Natural Science Foundation of Guangdong Province,China(Grant No.:2021A1515012219)Guangzhou University of Chinese Medicine“Double First-Class”and High-level University Discipline Collaborative Innovation Team Project,China(Grant No.:2021xk81) and Graduate Research Innovation Project of Guangzhou University of Chinese Medicine,China.
文摘Inhibiting the death receptor 3(DR3)signaling pathway in group 3 innate lymphoid cells(ILC3s)presents a promising approach for promoting mucosal repair in individuals with ulcerative colitis(UC).Paeoniflorin,a prominent component of Paeonia lactiflora Pall.,has demonstrated the ability to restore barrier function in UC mice,but the precise mechanism remains unclear.In this study,we aimed to delve into whether paeoniflorin may promote intestinal mucosal repair in chronic colitis by inhibiting DR3 signaling in ILC3s.C57BL/6 mice were subjected to random allocation into 7 distinct groups,namely the control group,the 2%dextran sodium sulfate(DSS)group,the paeoniflorin groups(25,50,and 100 mg/kg),the anti-tumor necrosis factor-like ligand 1A(anti-TL1A)antibody group,and the IgG group.We detected the expression of DR3 signaling pathway proteins and the proportion of ILC3s in the mouse colon using Western blot and flow cytometry,respectively.Meanwhile,DR3-overexpressing MNK-3 cells and 2%DSS-induced Rag1^(-/-)mice were used for verification.The results showed that paeoniflorin alleviated DSS-induced chronic colitis and repaired the intestinal mucosal barrier.Simultaneously,paeoniflorin inhibited the DR3 signaling pathway in ILC3s and regulated the content of cytokines(interleukin-17A,granulocyte-macrophage colony stimulating factor,and interleukin-22).Alternatively,paeoniflorin directly inhibited the DR3 signaling pathway in ILC3s to repair mucosal damage independently of the adaptive immune system.We additionally confirmed that paeoniflorin-conditioned medium(CM)restored the expression of tight junctions in Caco-2 cells via coculture.In conclusion,paeoniflorin ameliorates chronic colitis by enhancing the intestinal barrier in an ILC3-dependent manner,and its mechanism is associated with the inhibition of the DR3 signaling pathway.
文摘It has been well identified that the extreme events significantly impact the system operation. In this work, a comprehensive operating strategy, which coordinates the preventive strategies and system restoration, was proposed. A re-dispatch model that limits the potential loss under extreme events, as well as provides adequate resources for system restoration after the extreme events, was proposed. An optimal power flow based method was established to solve the proposed model. The availabilities of components and the remaining system due to the extreme events were restored by extending the EPRI’s System Restoration Navigator (SRN) with a little modification. Case studies demonstrate the proposed model and methods.
基金supported by the State Grid Guide Project(No.5108-202218030A-1-1-ZN)。
文摘In recent years, sub-synchronous oscillation accidents caused by wind power integration have received extensive attention. The recorded constant-amplitude waveforms can be induced by either linear or nonlinear oscillation mechanisms. Hence, the nonlinear behavior needs to be distinguished prior to choosing the analysis method. Since the 1960s, the higher-order statistics(HOS) theory has become a powerful tool for the detection of nonlinear behavior(DNB) in production quality control wherein it has mainly been applied to mechanical condition monitoring and fault diagnosis. This study focuses on the hard limiters of the voltage source converter(VSC) control systems in the wind farms and attempts to detect the nonlinear behavior caused by bi-or uni-lateral saturation hard limiting using the HOS analysis. First, the conventional describing function is extended to obtain the detailed frequency domain information on the bi-and uni-lateral saturation hard limiting. Furthermore, the bi-and tri-spectra are introduced as the HOS, which are extended into bi-and tri-coherence spectra to eliminate the effects of the linear parts on the harmonic characteristics of hard limiting in the VSC control system, respectively. The effectiveness of the HOS in the DNB and the classification of the hard-limiting types is proven, and its detailed derivation and estimation procedure is presented. Finally, the quadratic and cubic phase coupling in the signals is illustrated, and the performance of the proposed method is evaluated and discussed.
基金supported by the State Grid Guide Project(No.5108-202218030A-1-1-ZN).
文摘The oscillation phenomena associated with the control of voltage source converters(VSCs)are concerning,making it crucial to locate the sources of such oscillations and suppress the oscillations.Therefore,this paper presents a location scheme based on the energy structure and nonlinearity detection.The energy structure,which conforms to the principle of the energy-based method and dissipativity theory,is developed to describe the transient energy flow for VSCs,based on which a defined characteristic quantity is implemented to narrow the scope for locating the sources of oscillations.Moreover,based on the self-sustained oscillation characteristics of VsCs,an index for nonlinearity detection is applied to locate the VSCs that produce the oscillation energy.The combination of the energy structure and nonlinearity detection distinguishes the contribu-tions of different VSCs to the oscillation.The results of a case study implemented by the PSCAD/EMTDC simulation validate theproposed scheme.
基金supported in part by the National Natural Science Foundation of China (No.51877115)in part by China Postdoctoral Science Foundation (No.2021M691724)。
文摘With the rapid development of artificial intelligence(AI),it is foreseeable that the accuracy and efficiency of dynamic analysis for future power system will be greatly improved by the integration of dynamic simulators and AI.To explore the interaction mechanism of power system dynamic simulations and AI,a general design for AI-oriented power system dynamic simulators is proposed,which consists of a high-performance simulator with neural network supportability and flexible external and internal application programming interfaces(APIs).With the support of APIs,simulation-assisted AI and AIassisted simulation form a comprehensive interaction mechanism between power system dynamic simulations and AI.A prototype of this design is implemented and made public based on a highly efficient electromechanical simulator.Tests of this prototype are carried out in four scenarios including sample generation,AI-based stability prediction,data-driven dynamic component modeling,and AI-aided stability control,which prove the validity,flexibility,and efficiency of the design and implementation for AI-oriented power system dynamic simulators.
基金supported by National Natural Science Foundation of China(No.51377103)the technology project of State Grid Corporation of China:Research on Multi-Level Decomposition Coordination of the Pareto Set of Multi-Objective Optimization Problem in Bulk Power System(No.SGSXDKYDWKJ2015-001)the support from State Energy Smart Grid R&D Center(SHANGHAI)
文摘This paper employs an efficacious analytical tool,adaptive simplified human learning optimization(ASHLO)algorithm,to solve optimal power flow(OPF)problem in AC/DC hybrid power system,considering valve-point loading effects of generators,carbon tax,and prohibited operating zones of generators,respectively.ASHLO algorithm,involves random learning operator,individual learning operator,social learning operator and adaptive strategies.To compare and analyze the computation performance of the ASHLO method,the proposed ASHLO method and other heuristic intelligent optimization methods are employed to solve OPF problem on the modified IEEE 30-bus and 118-bus AC/DC hybrid test system.Numerical results indicate that the ASHLO method has good convergent property and robustness.Meanwhile,the impacts of wind speeds and locations of HVDC transmission line integrated into the AC network on the OPF results are systematically analyzed.