Objective The aim of the study was to study the correlation between the clinicopathological parameters of lung adenocarcinoma and lymph node metastasis and identify the risk factors of lymph node metastasis.Methods Th...Objective The aim of the study was to study the correlation between the clinicopathological parameters of lung adenocarcinoma and lymph node metastasis and identify the risk factors of lymph node metastasis.Methods The data of 258 patients with postoperative lung adenocarcinoma(mainly based on their pathological data)were collected and analyzed,and their basic information was counted.Results Maximum tumor diameter was found to be an independent risk factor for lymph node metastasis.The larger the maximum diameter of the tumor in patients with lung adenocarcinoma,the higher the likelihood of lymph node metastasis.Solid predominant adenocarcinoma with mucin production is as an independent risk factor for superior mediastinal and subcarinal lymph node metastasis.Primary adenocarcinomas in the lower lobe of the lung may have a higher rate of lymph node metastasis than those in the upper lobe.Conclusion The known pathological subtypes of lung adenocarcinoma can be used for the prediction of lymph node metastasis in various regions and guide the dissection of lymph nodes that would improve patients’prognosis.展开更多
Multivalent metal-ion batteries have attracted wide attention with the expectation of tackling the needs of large-scale electrochemical energy storage[1].Among them,rechargeable calcium(Ca)-ion batteries are known as ...Multivalent metal-ion batteries have attracted wide attention with the expectation of tackling the needs of large-scale electrochemical energy storage[1].Among them,rechargeable calcium(Ca)-ion batteries are known as a promising alternative to conventional lithium(Li)-ion batteries due to the high abundance of calcium(the fifth most abundant element in the earth’s crust)and its large theoretical capacity(2,073 m Ah cm^(-3))and potential(-2.87 V vs.standard hydrogen electrode,SHE)comparable to that of Li(-3.04 V vs.SHE).Furthermore,unlike monovalent cations,the divalent calcium cations favor a two-electron transfer to increase the specific energies[2].展开更多
Copper selenide (CurSe) has great potential as counter electrode for quantum dots sensitized solar cell (QDSSC) due to its excellent electrocatalytic activity and lower charge transfer resistance. A novel ion exch...Copper selenide (CurSe) has great potential as counter electrode for quantum dots sensitized solar cell (QDSSC) due to its excellent electrocatalytic activity and lower charge transfer resistance. A novel ion exchange method has been utilized to fabricate Cu3Se2 nanosheets array counter electrode. CdS layer was first deposited by sputtering and used as a template to grow compact and uni- form Cu3Se2 film in a typical chemical bath. The morphology and thickness of the Cu3Se2 nanosheets were controlled by the deposition time. The final products (2h-Cu3Se2) showed significantly improved electrochemical catalytic activity and carrier transport property, leading to a much increased power conversion efficiency (4.01%) when compared with the CuS counter electrode CdS/CdSe QDSSC (3.21%).展开更多
文摘Objective The aim of the study was to study the correlation between the clinicopathological parameters of lung adenocarcinoma and lymph node metastasis and identify the risk factors of lymph node metastasis.Methods The data of 258 patients with postoperative lung adenocarcinoma(mainly based on their pathological data)were collected and analyzed,and their basic information was counted.Results Maximum tumor diameter was found to be an independent risk factor for lymph node metastasis.The larger the maximum diameter of the tumor in patients with lung adenocarcinoma,the higher the likelihood of lymph node metastasis.Solid predominant adenocarcinoma with mucin production is as an independent risk factor for superior mediastinal and subcarinal lymph node metastasis.Primary adenocarcinomas in the lower lobe of the lung may have a higher rate of lymph node metastasis than those in the upper lobe.Conclusion The known pathological subtypes of lung adenocarcinoma can be used for the prediction of lymph node metastasis in various regions and guide the dissection of lymph nodes that would improve patients’prognosis.
文摘Multivalent metal-ion batteries have attracted wide attention with the expectation of tackling the needs of large-scale electrochemical energy storage[1].Among them,rechargeable calcium(Ca)-ion batteries are known as a promising alternative to conventional lithium(Li)-ion batteries due to the high abundance of calcium(the fifth most abundant element in the earth’s crust)and its large theoretical capacity(2,073 m Ah cm^(-3))and potential(-2.87 V vs.standard hydrogen electrode,SHE)comparable to that of Li(-3.04 V vs.SHE).Furthermore,unlike monovalent cations,the divalent calcium cations favor a two-electron transfer to increase the specific energies[2].
基金supported by the National Natural Science Foundation of China (51374029 and 51611130063)Fundamental Research Funds for the Central Universities (FRF-BD-16-012A)111 Project (B17003)
文摘Copper selenide (CurSe) has great potential as counter electrode for quantum dots sensitized solar cell (QDSSC) due to its excellent electrocatalytic activity and lower charge transfer resistance. A novel ion exchange method has been utilized to fabricate Cu3Se2 nanosheets array counter electrode. CdS layer was first deposited by sputtering and used as a template to grow compact and uni- form Cu3Se2 film in a typical chemical bath. The morphology and thickness of the Cu3Se2 nanosheets were controlled by the deposition time. The final products (2h-Cu3Se2) showed significantly improved electrochemical catalytic activity and carrier transport property, leading to a much increased power conversion efficiency (4.01%) when compared with the CuS counter electrode CdS/CdSe QDSSC (3.21%).