A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopt...A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopts an inte-grated approach,combining the shift register analysis mode with the pulse-position timestamp mode using an FPGA.The optimal effective length of the^(3)He neutron detector was determined to be 30 cm,and the thickness of the graphite reflector was ascertained to be 15 cm through MCNP simulations.After fabricating the device,calibration measurements were per-formed using a^(252)Cf neutron source;a detection efficiency of 43.07%and detector die-away time of 55.79μs were observed.Nine samples of plutonium oxide were measured under identical conditions using the FH-NCM/S1 in shift register analysis mode and a plutonium waste multiplicity counter.The obtained double rates underwent corrections for detection efficiency(ε)and double gate fraction(f_(d)),resulting in corrected double rates(D_(c)),which were used to validate the accuracy of the shift register analysis mode.Furthermore,the device exhibited fluctuations in the measurement results,and within a single 20 s measurement,these fluctuations remained below 10%.After 30 cycles,the relative error in the mass of^(240)Pu was less than 5%.Finally,correlation calculations confirmed the robust consistency of both measurement modes.This study holds specific significance for the subsequent design and development of neutron multiplicity devices.展开更多
The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and...The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and the radon-progeny equilibrium factor, cigarettes are used to simulate the haze–fog in a multi-functional radon chamber to achieve a stable radon concentration environment. A radon detector and a portable laser aerosol spectrometer are used to obtain the values for C_(mean) PM2.5,C_(Rn), and C_p. The results show that the mean values of F conform with the typical value recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation and are within the reasonable range of0.1–0.9. In this study, a positive correlation is observed between the F values and PM2.5 concentrations.展开更多
基金supported by the National Natural Science Foundation of China(No.42374226)Natural Science Foundation of Jiangxi Province(Nos.20232BAB201043 and 20232BCJ23006)+1 种基金a sub-project of the nuclear energy development project of the China National Defense Science and Industry Bureau‘n-γfusion logging method theory research’(No.20201192-01)the Fundamental Science on Radioactive Geology and Exploration Technology Laboratory(No.2022RGET20)。
文摘A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopts an inte-grated approach,combining the shift register analysis mode with the pulse-position timestamp mode using an FPGA.The optimal effective length of the^(3)He neutron detector was determined to be 30 cm,and the thickness of the graphite reflector was ascertained to be 15 cm through MCNP simulations.After fabricating the device,calibration measurements were per-formed using a^(252)Cf neutron source;a detection efficiency of 43.07%and detector die-away time of 55.79μs were observed.Nine samples of plutonium oxide were measured under identical conditions using the FH-NCM/S1 in shift register analysis mode and a plutonium waste multiplicity counter.The obtained double rates underwent corrections for detection efficiency(ε)and double gate fraction(f_(d)),resulting in corrected double rates(D_(c)),which were used to validate the accuracy of the shift register analysis mode.Furthermore,the device exhibited fluctuations in the measurement results,and within a single 20 s measurement,these fluctuations remained below 10%.After 30 cycles,the relative error in the mass of^(240)Pu was less than 5%.Finally,correlation calculations confirmed the robust consistency of both measurement modes.This study holds specific significance for the subsequent design and development of neutron multiplicity devices.
基金supported by the National Natural Science Foundation of China(No.11565002)the Jiang Xi Young Science Foundation Project(No.GJJ150558)Open Funds of Engineering Research Center of Nuclear Technology Application of Ministry of Education(No.HJSJYB2017-2)
文摘The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and the radon-progeny equilibrium factor, cigarettes are used to simulate the haze–fog in a multi-functional radon chamber to achieve a stable radon concentration environment. A radon detector and a portable laser aerosol spectrometer are used to obtain the values for C_(mean) PM2.5,C_(Rn), and C_p. The results show that the mean values of F conform with the typical value recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation and are within the reasonable range of0.1–0.9. In this study, a positive correlation is observed between the F values and PM2.5 concentrations.