期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Passive neutron multiplicity device for^(240)Pu measurement based on FPGA
1
作者 Yan Zhang Hao-Ran Zhang +6 位作者 Ren-Bo Wang Ming-Yu Li Rui Chen Hai-Tao Wang Xiang-Ting Meng shu-min zhou Bin Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期141-154,共14页
A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopt... A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopts an inte-grated approach,combining the shift register analysis mode with the pulse-position timestamp mode using an FPGA.The optimal effective length of the^(3)He neutron detector was determined to be 30 cm,and the thickness of the graphite reflector was ascertained to be 15 cm through MCNP simulations.After fabricating the device,calibration measurements were per-formed using a^(252)Cf neutron source;a detection efficiency of 43.07%and detector die-away time of 55.79μs were observed.Nine samples of plutonium oxide were measured under identical conditions using the FH-NCM/S1 in shift register analysis mode and a plutonium waste multiplicity counter.The obtained double rates underwent corrections for detection efficiency(ε)and double gate fraction(f_(d)),resulting in corrected double rates(D_(c)),which were used to validate the accuracy of the shift register analysis mode.Furthermore,the device exhibited fluctuations in the measurement results,and within a single 20 s measurement,these fluctuations remained below 10%.After 30 cycles,the relative error in the mass of^(240)Pu was less than 5%.Finally,correlation calculations confirmed the robust consistency of both measurement modes.This study holds specific significance for the subsequent design and development of neutron multiplicity devices. 展开更多
关键词 Spent fuel Non-destructive assay Neutron multiplicity ^(240)Pu FPGA
下载PDF
Evaluation of correlation between PM2.5 and radon-progeny equilibrium factor in radon chamber 被引量:4
2
作者 Li-Fan Li Rui Chen +1 位作者 shu-min zhou Bin Tang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第10期261-267,共7页
The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and... The dosage of environmental radon progeny is typically estimated according to the environmental radon exposure and the recommended radon-progeny equilibrium factor, F. To investigate the relationship between PM2.5 and the radon-progeny equilibrium factor, cigarettes are used to simulate the haze–fog in a multi-functional radon chamber to achieve a stable radon concentration environment. A radon detector and a portable laser aerosol spectrometer are used to obtain the values for C_(mean) PM2.5,C_(Rn), and C_p. The results show that the mean values of F conform with the typical value recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation and are within the reasonable range of0.1–0.9. In this study, a positive correlation is observed between the F values and PM2.5 concentrations. 展开更多
关键词 PM2.5 RADON CHAMBER EQUILIBRIUM FACTOR Linear regression
下载PDF
上一页 1 下一页 到第