The potential utilization and development of the Ba isotope tool depend on an accurateδ^(137/134)Ba determination of the samples.During the chemical purification,whether the adsorption process on the surface of the i...The potential utilization and development of the Ba isotope tool depend on an accurateδ^(137/134)Ba determination of the samples.During the chemical purification,whether the adsorption process on the surface of the ionexchange resin could lead to the Ba isotopic fractionation and the degree of fractionation directly influence the accurateδ^(137/134)Ba determination.In the present work,first-principles calculations based on the density functional theory were used to quantify the Ba isotopic equilibrium fractionation factor between the aqueous solution and the resin in the acid leaching process.By constructing and optimizing the geometric configurations of Ba-containing species,Ba(H_(2)O)_(n)^(2+),Ba(H_(2)O)_(n)Cl_(2),Ba(H_(2)O)_(n)(NO_(3))2,and the adsorbed Ba^(2+)on the surface of the resin,extracting the harmonic vibrational frequencies,we finally at 298 K obtained the fractionations,Δ^(137/134)Ba_(soln-ads)=0.07‰,Δ^(137/134)Ba_(Ba(H_(2)O)_(n)Cl_(2)-ads)=0.05‰,andΔ^(137/134)-Ba^(Ba(H_(2)O)_(n)(NO_(3))2-ads)=0.02‰.Overall,there were almost no Ba isotope fractionations during leaching.Although the Ba isotope fractionation can be magnified by the Rayleigh fractionation process in purification,the difference inδ137/134Ba between the initial and final stages did not exceed0.060‰(or 0.045‰)when leaching the standard sample with HCl or HNO_(3),which is equal to or less than the accuracy of Ba isotopic analysis.At a common yield of89.75%,Ba isotopic fractionation induced by incomplete recovery was 0.015‰for HCl(or 0.011‰for HNO_(3)).Finally,if the influence of an incomplete recovery on theδ137/134Ba determination needs to be ignored,the recovery is suggested to be not less than 67%for HCl(or 46%for HNO_(3)).展开更多
基金financially supported by the Hebei Natural Sciences Foundation(Grant Nos.D2020402004 and D2021402020)Hebei Education Department Key Program(Grant No.ZD2018086)+1 种基金the State Natural Sciences Foundation(Grant No.41603011)Hebei University of Engineering Doctoral Special Program(Grant Nos.17129033019 and 17129033020)。
文摘The potential utilization and development of the Ba isotope tool depend on an accurateδ^(137/134)Ba determination of the samples.During the chemical purification,whether the adsorption process on the surface of the ionexchange resin could lead to the Ba isotopic fractionation and the degree of fractionation directly influence the accurateδ^(137/134)Ba determination.In the present work,first-principles calculations based on the density functional theory were used to quantify the Ba isotopic equilibrium fractionation factor between the aqueous solution and the resin in the acid leaching process.By constructing and optimizing the geometric configurations of Ba-containing species,Ba(H_(2)O)_(n)^(2+),Ba(H_(2)O)_(n)Cl_(2),Ba(H_(2)O)_(n)(NO_(3))2,and the adsorbed Ba^(2+)on the surface of the resin,extracting the harmonic vibrational frequencies,we finally at 298 K obtained the fractionations,Δ^(137/134)Ba_(soln-ads)=0.07‰,Δ^(137/134)Ba_(Ba(H_(2)O)_(n)Cl_(2)-ads)=0.05‰,andΔ^(137/134)-Ba^(Ba(H_(2)O)_(n)(NO_(3))2-ads)=0.02‰.Overall,there were almost no Ba isotope fractionations during leaching.Although the Ba isotope fractionation can be magnified by the Rayleigh fractionation process in purification,the difference inδ137/134Ba between the initial and final stages did not exceed0.060‰(or 0.045‰)when leaching the standard sample with HCl or HNO_(3),which is equal to or less than the accuracy of Ba isotopic analysis.At a common yield of89.75%,Ba isotopic fractionation induced by incomplete recovery was 0.015‰for HCl(or 0.011‰for HNO_(3)).Finally,if the influence of an incomplete recovery on theδ137/134Ba determination needs to be ignored,the recovery is suggested to be not less than 67%for HCl(or 46%for HNO_(3)).