Objective To investigate whether plasma big endothelin-1(ET-1) predicts ventricular arrythmias(VAs) and end-stage events in primary prevention implantable cardioverter-defibrillator(ICD) indication patigents. Methods ...Objective To investigate whether plasma big endothelin-1(ET-1) predicts ventricular arrythmias(VAs) and end-stage events in primary prevention implantable cardioverter-defibrillator(ICD) indication patigents. Methods In total, 207 patients fulfilling the inclusion criteria from Fuwai Hospital between January 2013 and December 2015 were retrospectively analyzed. The cohort was divided into three groups according to baseline plasma big ET-1 tertiles: tertile 1(< 0.38 pmol/L, n = 68), tertile 2(0.38–0.7 pmol/L, n = 69), and tertile 3(> 0.7 pmol/L, n = 70). The primary endpoints were VAs. The secondary endpoints were end-stage events comprising all-cause mortality and heart transplantation. Results During a mean follow-up period of 25.6 ± 13.9 months, 38(18.4%) VAs and 78(37.7%) end-stage events occurred. Big ET-1 was positively correlated with NYHA class(r = 0.165, P = 0.018), serum creatinine concentration(Scr;r = 0.147, P = 0.034), high-sensitivity C-reactive protein(hs-CRP;r = 0.217, P = 0.002), Lg NT-pro BNP(r = 0.463, P < 0.001), left ventricular end diastolic diameter(LVEDD;r = 0.234, P = 0.039) and negatively correlated with left ventricular ejection fraction(LVEF;r =-0.181, P = 0.032). Kaplan-Meier analysis showed that elevated big ET-1 was associated with increased risk of VAs and end-stage events(P < 0.05). In multivariate Cox regression models, big ET-1 was an independent risk factor for VAs(hazard ratio(HR) = 3.477, 95% confidence interval(CI): 1.352–8.940, P = 0.010, tertile 2 vs. tertile 1;HR = 4.112, 95% CI: 1.604–10.540, P = 0.003, tertile 3 vs. tertile 1) and end-stage events(HR = 2.804, 95% CI: 1.354–5.806, P = 0.005, tertile 2 vs. tertile 1;HR = 4.652, 95% CI: 2.288–9.459, P < 0.001, tertile 3 vs. tertile 1). Conclusions In primary prevention ICD indication patients, plasma big ET-1 levels can predict VAs and end-stage events and may facilitate ICD-implantation risk stratification.展开更多
The spin-polarized photocurrent is used to study the in-plane electric field dependent spin transport in undoped InGaAs/AlGaAs multiple quantum wells. In the temperature range of 77–297 K, the spin-polarized photocur...The spin-polarized photocurrent is used to study the in-plane electric field dependent spin transport in undoped InGaAs/AlGaAs multiple quantum wells. In the temperature range of 77–297 K, the spin-polarized photocurrent shows an anisotropic spin transport under different oriented in-plane electric fields. We ascribe this characteristic to two dominant mechanisms: the hot phonon effect and the Rashba spin-orbit effect which is influenced by the in-plane electric fields with different orientations. The formulas are proposed to fit our experiments, suggesting a guide of potential applications and devices.展开更多
基金supported by Natural Science Foundation of China(81470466)。
文摘Objective To investigate whether plasma big endothelin-1(ET-1) predicts ventricular arrythmias(VAs) and end-stage events in primary prevention implantable cardioverter-defibrillator(ICD) indication patigents. Methods In total, 207 patients fulfilling the inclusion criteria from Fuwai Hospital between January 2013 and December 2015 were retrospectively analyzed. The cohort was divided into three groups according to baseline plasma big ET-1 tertiles: tertile 1(< 0.38 pmol/L, n = 68), tertile 2(0.38–0.7 pmol/L, n = 69), and tertile 3(> 0.7 pmol/L, n = 70). The primary endpoints were VAs. The secondary endpoints were end-stage events comprising all-cause mortality and heart transplantation. Results During a mean follow-up period of 25.6 ± 13.9 months, 38(18.4%) VAs and 78(37.7%) end-stage events occurred. Big ET-1 was positively correlated with NYHA class(r = 0.165, P = 0.018), serum creatinine concentration(Scr;r = 0.147, P = 0.034), high-sensitivity C-reactive protein(hs-CRP;r = 0.217, P = 0.002), Lg NT-pro BNP(r = 0.463, P < 0.001), left ventricular end diastolic diameter(LVEDD;r = 0.234, P = 0.039) and negatively correlated with left ventricular ejection fraction(LVEF;r =-0.181, P = 0.032). Kaplan-Meier analysis showed that elevated big ET-1 was associated with increased risk of VAs and end-stage events(P < 0.05). In multivariate Cox regression models, big ET-1 was an independent risk factor for VAs(hazard ratio(HR) = 3.477, 95% confidence interval(CI): 1.352–8.940, P = 0.010, tertile 2 vs. tertile 1;HR = 4.112, 95% CI: 1.604–10.540, P = 0.003, tertile 3 vs. tertile 1) and end-stage events(HR = 2.804, 95% CI: 1.354–5.806, P = 0.005, tertile 2 vs. tertile 1;HR = 4.652, 95% CI: 2.288–9.459, P < 0.001, tertile 3 vs. tertile 1). Conclusions In primary prevention ICD indication patients, plasma big ET-1 levels can predict VAs and end-stage events and may facilitate ICD-implantation risk stratification.
基金Supported by the National Basic Research Program of China under Grant No 2015CB921503the National Natural Science Foundation of China under Grant Nos 61474114,11574302,61627822 and 11704032the National Key Research and Development Program of China under Grant Nos 2018YFA0209103,2016YFB0402303 and 2016YFB0400101
文摘The spin-polarized photocurrent is used to study the in-plane electric field dependent spin transport in undoped InGaAs/AlGaAs multiple quantum wells. In the temperature range of 77–297 K, the spin-polarized photocurrent shows an anisotropic spin transport under different oriented in-plane electric fields. We ascribe this characteristic to two dominant mechanisms: the hot phonon effect and the Rashba spin-orbit effect which is influenced by the in-plane electric fields with different orientations. The formulas are proposed to fit our experiments, suggesting a guide of potential applications and devices.