In this paper, the effect of injected energy on low energy single longitudinal mode (SLM) pre-lase Q-switched is analyzed and the optimization procedure is shown in detail. Here, taking the Pr:YLF laser as an example ...In this paper, the effect of injected energy on low energy single longitudinal mode (SLM) pre-lase Q-switched is analyzed and the optimization procedure is shown in detail. Here, taking the Pr:YLF laser as an example of low energy laser, and the parameters of Pr:YLF laser by using pre-lase have been shown. Compared with normal Q-switched laser, the single pulse energy reaches 60.16% and the pulse width exceeds 39.73% when the same maximum energy is injected and SLM is achieved in pre-lase. The analysis results show that pre-lase is suitable for low energy laser to obtain SLM and there be an optimal performance to achieve the optimal energy output.展开更多
The output characteristics of a narrow linewidth, no-gain competition, dual-wavelength solid-state laser using an intra-cavity pumped method are reported. This system consists of an intra-cavity pumped Nd:YVO4 laser e...The output characteristics of a narrow linewidth, no-gain competition, dual-wavelength solid-state laser using an intra-cavity pumped method are reported. This system consists of an intra-cavity pumped Nd:YVO4 laser emitting at 1064 nm, using a 912 nm Nd:GdVO4 laser. A Fabry-Perot etalon is used to compress the linewidth that located at the common cavity of 912 nm and 1064 nm laser. Theoretical analysis and experimental verification were carried out. When the pump power is 32.8 W, the output of 912 nm and 1064 nm theoretical value is 0.036 W and 0.046 W, and the experimental value is 0.017 W and 0.016 W, respectively. The change trend of the theoretical simulated output power value was the same as the actual measured value in the experiment. In addition to this, the experimental measurement shows when the etalon with an angle of 15?, corresponding minimum linewidths were 0.284 nm and 0.627 nm, respectively.展开更多
文摘In this paper, the effect of injected energy on low energy single longitudinal mode (SLM) pre-lase Q-switched is analyzed and the optimization procedure is shown in detail. Here, taking the Pr:YLF laser as an example of low energy laser, and the parameters of Pr:YLF laser by using pre-lase have been shown. Compared with normal Q-switched laser, the single pulse energy reaches 60.16% and the pulse width exceeds 39.73% when the same maximum energy is injected and SLM is achieved in pre-lase. The analysis results show that pre-lase is suitable for low energy laser to obtain SLM and there be an optimal performance to achieve the optimal energy output.
文摘The output characteristics of a narrow linewidth, no-gain competition, dual-wavelength solid-state laser using an intra-cavity pumped method are reported. This system consists of an intra-cavity pumped Nd:YVO4 laser emitting at 1064 nm, using a 912 nm Nd:GdVO4 laser. A Fabry-Perot etalon is used to compress the linewidth that located at the common cavity of 912 nm and 1064 nm laser. Theoretical analysis and experimental verification were carried out. When the pump power is 32.8 W, the output of 912 nm and 1064 nm theoretical value is 0.036 W and 0.046 W, and the experimental value is 0.017 W and 0.016 W, respectively. The change trend of the theoretical simulated output power value was the same as the actual measured value in the experiment. In addition to this, the experimental measurement shows when the etalon with an angle of 15?, corresponding minimum linewidths were 0.284 nm and 0.627 nm, respectively.