The high-energy photon source(HEPS)is the first fourth-generation synchrotron light source facility in China.The HEPS injector consists of a linear accelerator(Linac)and a full energy booster.The booster captures the ...The high-energy photon source(HEPS)is the first fourth-generation synchrotron light source facility in China.The HEPS injector consists of a linear accelerator(Linac)and a full energy booster.The booster captures the electron beam from the Linac and increases its energy to the value required for the storage ring.The full-energy beam could be injected to the storage ring directly or after“high-energy accumulation.”On November 17,2023,the key booster parameters successfully reached their corresponding target values.These milestone results were achieved based on numerous contributions,including nearly a decade of physical design,years of equipment development and installation,and months of beam commissioning.As measured at the extraction energy of 6 GeV,the averaged beam current and emittance reached 8.57 mA with 5 bunches and 30.37 nm rad with a single-bunch charge of 5.58 nC,compared with the corresponding target values of 6.6 mA and 35 nm rad,respectively.This paper presents the physical design,equipment development,installation,and commissioning process of the HEPS booster.展开更多
High-energy photon source(HEPS) is a 6 GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 lm. It is a chal...High-energy photon source(HEPS) is a 6 GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 lm. It is a challenge to measure such a small beam size in both directions. To this end, measurement by a Kirkpatrick–Baez(KB) mirror imaging system was evaluated. A test KB system for the Shanghai Synchrotron Radiation Facility storage ring was designed and tested. Two crossed cylindrical mirrors were used to image the dipole source point. Both mirrors can be moved in and out so that the monitor is interchangeable with the original X-ray pinhole monitor. The aberration and point spread function, which would cause image blur, were evaluated. A beam-based calibration scheme was used by varying the beam size with different quadrupole settings and fitting them with the corresponding theoretical values.We updated the original X-ray camera with a new camera having a 5-lm-thick LuAG/Ce scintillator, and the imaging result shows greatly decreased image blur.展开更多
At the High Energy Photon Source (HEPS),a high orbital stability of typically 10% of the beam size and angular divergence must be achieved.The beam size at the insertion devices is 10μm horizontally and 1μm vertical...At the High Energy Photon Source (HEPS),a high orbital stability of typically 10% of the beam size and angular divergence must be achieved.The beam size at the insertion devices is 10μm horizontally and 1μm vertically,which implies that the beam orbit must be stabilized to the sub-micrometer level.This results in stringent tolerance and quality control requirements for the series production of beam position monitor (BPM) pickups.In this study,analytical formulas were used and CST simulations were performed to analyze the effects of the mechanical tolerances of BPM pickups on beam position measurement.The results of electromagnetic?eld simulations revealed how various mechanical errors,such as button size and location accuracy,as well as the related button capacitance,exert different in?uences on the beam position measurement.The performance of an actual BPM pickup was measured,along with an assessment of the error on the beam position measurement.Additionally,a wake?eld analysis,including an investigation of trapped resonant modes and related thermal deformation,was conducted.展开更多
To establish a nuclear resonant scattering beamline at the High Energy Photon Source(HEPS),it is essential to develop tools for detection and cleaning of parasitic bunches,for meeting the stringent demands on bunch pu...To establish a nuclear resonant scattering beamline at the High Energy Photon Source(HEPS),it is essential to develop tools for detection and cleaning of parasitic bunches,for meeting the stringent demands on bunch purity.To this end,a novel time-correlated single-photon counting system was implemented at the electron storage ring of the Beijing Electron–Positron Collider II(BEPCII).The purity deterioration process over a week-long operation was recorded by the system.In this study,the mechanism of impurity growth was analyzed by numerical methods and validated on measurements.The agreement between the experimental results and the cal-culation was fairly good.Two main sources of parasitic bunches,pre-accelerators and the Touschek scattering were confirmed.A bunch-cleaning technique,based on a sinu-soidal signal mixed with a pseudo-square wave,was also developed and implemented,and its capability to improve the bunch purity to the level of 10–7 was experimentally demonstrated.We present the experimental setup,princi-ple,and measurement results of a system for detection and cleaning of parasitic bunches.展开更多
The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conduct...The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conducting(SC)linear accelerator(linac)for the ADS project in China.The injector adopted a four-vane copper structure radio frequency quadrupole(RFQ)with an output energy of 3.2 MeV and an SC section accommodating 14 β_(g)=0.12 single spoke cavities,14 SC solenoids,and 14 cold beam position monitors(BPMs).A 10-MeV pulsed beam with a beam current of 10 mA and a 2-mA continuous wave(CW)beam were successfully shooting through.The commissioning results confirmed the feasibility of using a 325-MHz spoke-type cavity for accelerating the proton beam in the low β and medium β sections.This paper describes the results achieved,the difficulties encountered,and the experiences obtained during commissioning.展开更多
Background The tune is one of the most important parameters of the storage ring which play a crucial role in the brightness optimization.The synchrotron radiation will suppress the oscillation and make the detection u...Background The tune is one of the most important parameters of the storage ring which play a crucial role in the brightness optimization.The synchrotron radiation will suppress the oscillation and make the detection unusual difficulty without any kicker excitation.Purpose A new high sensitivity tune measurement system is developed to show the real-time tune during the colliding.Method Peak diode detectors are used to convert short beam pulses from a button BPM into slowly varying signals.Their DC components,constituting a large background related to beam offsets,are suppressed by series capacitors,while the small signals related to beam oscillations are passed to the subsequent stages for amplification and filtering.Conclusion A direct diode detection technique based on the diode peak hold circuit could increase the sensitivity by hundreds time which gets a clearly tune peak even with synchrotron radiation and bunch-by-bunch feedback damping.展开更多
基金This work was supported by the National Natural Science Foundation of China(No.12005239).
文摘The high-energy photon source(HEPS)is the first fourth-generation synchrotron light source facility in China.The HEPS injector consists of a linear accelerator(Linac)and a full energy booster.The booster captures the electron beam from the Linac and increases its energy to the value required for the storage ring.The full-energy beam could be injected to the storage ring directly or after“high-energy accumulation.”On November 17,2023,the key booster parameters successfully reached their corresponding target values.These milestone results were achieved based on numerous contributions,including nearly a decade of physical design,years of equipment development and installation,and months of beam commissioning.As measured at the extraction energy of 6 GeV,the averaged beam current and emittance reached 8.57 mA with 5 bunches and 30.37 nm rad with a single-bunch charge of 5.58 nC,compared with the corresponding target values of 6.6 mA and 35 nm rad,respectively.This paper presents the physical design,equipment development,installation,and commissioning process of the HEPS booster.
文摘High-energy photon source(HEPS) is a 6 GeV ultralow emittance storage ring light source to be built in Beijing, China. Both the horizontal and vertical beam sizes of the HEPS storage ring are below 10 lm. It is a challenge to measure such a small beam size in both directions. To this end, measurement by a Kirkpatrick–Baez(KB) mirror imaging system was evaluated. A test KB system for the Shanghai Synchrotron Radiation Facility storage ring was designed and tested. Two crossed cylindrical mirrors were used to image the dipole source point. Both mirrors can be moved in and out so that the monitor is interchangeable with the original X-ray pinhole monitor. The aberration and point spread function, which would cause image blur, were evaluated. A beam-based calibration scheme was used by varying the beam size with different quadrupole settings and fitting them with the corresponding theoretical values.We updated the original X-ray camera with a new camera having a 5-lm-thick LuAG/Ce scintillator, and the imaging result shows greatly decreased image blur.
基金supported by the Youth Innovation Promotion Association CAS (Nos. 2019013 and Y202005)the National Natural Science Foundation of China (No. 11975254)
文摘At the High Energy Photon Source (HEPS),a high orbital stability of typically 10% of the beam size and angular divergence must be achieved.The beam size at the insertion devices is 10μm horizontally and 1μm vertically,which implies that the beam orbit must be stabilized to the sub-micrometer level.This results in stringent tolerance and quality control requirements for the series production of beam position monitor (BPM) pickups.In this study,analytical formulas were used and CST simulations were performed to analyze the effects of the mechanical tolerances of BPM pickups on beam position measurement.The results of electromagnetic?eld simulations revealed how various mechanical errors,such as button size and location accuracy,as well as the related button capacitance,exert different in?uences on the beam position measurement.The performance of an actual BPM pickup was measured,along with an assessment of the error on the beam position measurement.Additionally,a wake?eld analysis,including an investigation of trapped resonant modes and related thermal deformation,was conducted.
基金This work was supported by the Foundation of Youth Innovation Promotion Association under contracts 2019013 and Y202005,CAS.
文摘To establish a nuclear resonant scattering beamline at the High Energy Photon Source(HEPS),it is essential to develop tools for detection and cleaning of parasitic bunches,for meeting the stringent demands on bunch purity.To this end,a novel time-correlated single-photon counting system was implemented at the electron storage ring of the Beijing Electron–Positron Collider II(BEPCII).The purity deterioration process over a week-long operation was recorded by the system.In this study,the mechanism of impurity growth was analyzed by numerical methods and validated on measurements.The agreement between the experimental results and the cal-culation was fairly good.Two main sources of parasitic bunches,pre-accelerators and the Touschek scattering were confirmed.A bunch-cleaning technique,based on a sinu-soidal signal mixed with a pseudo-square wave,was also developed and implemented,and its capability to improve the bunch purity to the level of 10–7 was experimentally demonstrated.We present the experimental setup,princi-ple,and measurement results of a system for detection and cleaning of parasitic bunches.
基金This work was supported by Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA03030201)the Key Laboratory of Particle Acceleration Physics and Technology Autonomous Foundation of CAS China(No.JSQ2017ZZ01).
文摘The 10-MeV Accelerator-Driven Subcritical(ADS)system Injector-I test stand at the Institute of High Energy Physics(IHEP)is a testing facility dedicated to demonstrating the feasibility of the spoke-based super-conducting(SC)linear accelerator(linac)for the ADS project in China.The injector adopted a four-vane copper structure radio frequency quadrupole(RFQ)with an output energy of 3.2 MeV and an SC section accommodating 14 β_(g)=0.12 single spoke cavities,14 SC solenoids,and 14 cold beam position monitors(BPMs).A 10-MeV pulsed beam with a beam current of 10 mA and a 2-mA continuous wave(CW)beam were successfully shooting through.The commissioning results confirmed the feasibility of using a 325-MHz spoke-type cavity for accelerating the proton beam in the low β and medium β sections.This paper describes the results achieved,the difficulties encountered,and the experiences obtained during commissioning.
基金Funding This work was funded by the Youth Innovation Promotion Association CAS(No.2019013 and Y202005)the National Natural Science Foundation of China(No.11975254).
文摘Background The tune is one of the most important parameters of the storage ring which play a crucial role in the brightness optimization.The synchrotron radiation will suppress the oscillation and make the detection unusual difficulty without any kicker excitation.Purpose A new high sensitivity tune measurement system is developed to show the real-time tune during the colliding.Method Peak diode detectors are used to convert short beam pulses from a button BPM into slowly varying signals.Their DC components,constituting a large background related to beam offsets,are suppressed by series capacitors,while the small signals related to beam oscillations are passed to the subsequent stages for amplification and filtering.Conclusion A direct diode detection technique based on the diode peak hold circuit could increase the sensitivity by hundreds time which gets a clearly tune peak even with synchrotron radiation and bunch-by-bunch feedback damping.