A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/me...A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/methylene chloride (1:1, v/v) by ultrasonic extraction and the samples were cleaned up by concentrated sulfuric acid and Alumina-N solid phase extraction cartridge. The analytes were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5 - 200 ng/mL and the correlation coefficients were 0.9994 - 0.9998. The limit of quantitation (LOQ) for target analytes ranged from 6.0 to 10.0 μg/kg. At the spiked levels of 10, 50, 100 μg/kg, the average recoveries ranged from 90.9% to 102% with the relative standard deviations 2.12% - 6.32%. The result showed that the proposed method was rapid, and could be used for the determination of the PCBs in porphyra.展开更多
Endogenous formaldehyde in aquatic products is a hot research topic, as it is an urgent problem to be solved. This paper summarized the advance in background concentration, generation mechanism and detection methods o...Endogenous formaldehyde in aquatic products is a hot research topic, as it is an urgent problem to be solved. This paper summarized the advance in background concentration, generation mechanism and detection methods of endogenous formaldehyde in aquatic products, and the work in the future was prospected.展开更多
文摘A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/methylene chloride (1:1, v/v) by ultrasonic extraction and the samples were cleaned up by concentrated sulfuric acid and Alumina-N solid phase extraction cartridge. The analytes were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5 - 200 ng/mL and the correlation coefficients were 0.9994 - 0.9998. The limit of quantitation (LOQ) for target analytes ranged from 6.0 to 10.0 μg/kg. At the spiked levels of 10, 50, 100 μg/kg, the average recoveries ranged from 90.9% to 102% with the relative standard deviations 2.12% - 6.32%. The result showed that the proposed method was rapid, and could be used for the determination of the PCBs in porphyra.
文摘Endogenous formaldehyde in aquatic products is a hot research topic, as it is an urgent problem to be solved. This paper summarized the advance in background concentration, generation mechanism and detection methods of endogenous formaldehyde in aquatic products, and the work in the future was prospected.