The observed deflections and internal forces of pile-anchor retaining excavation were studied in spring area in Jinan city of China. Based on field measured data, the ground surface settlement, deflection of retaining...The observed deflections and internal forces of pile-anchor retaining excavation were studied in spring area in Jinan city of China. Based on field measured data, the ground surface settlement, deflection of retaining piles and wall, internal force analysis of concrete piles, axial anchoring forces, groundwater table, and the deformation of surround building and pipelines were investigated. The results indicates that the combining application of concrete piles, jet grouting columns and anchors support system can effectively control excavation-induced surface ground settlements. The field maximum lateral wall deflections are between 0.o2% and o.19% of the excavation depth due to the competitive site conditions. The bending moment-depth relationship curve is S-type. Groundwater leakage results in the sharp drop in groundwater level, which is part of the reasons for the adjacent building settlement. The axial anchoring forces of the upper layer of anchors increase gradually during the excavation, but those of the lower layer of anchors slightly reduced firstly and then tend to be stable during the excavation procedure. In comparison with the histories of excavation cases, the small lateral wall deflection in this study results from the favorable site condition and the relative rigidity of the retaining structure system.展开更多
基金Project(52078129)supported by the National Natural Science Foundation of ChinaProjects(KYCX22_0268,SJCX21_0031)supported by the Postgraduate Research&Practice Innovation Program of Jiangsu Province,China。
基金supported by the Chinese Fundamental Research Funds for the Central Universities(Grant No.2242014R30020)the Personnel Training Fund for Outstanding Young Teacher of Qinglan Project of Higher Education in Jiangsu Province,China
文摘The observed deflections and internal forces of pile-anchor retaining excavation were studied in spring area in Jinan city of China. Based on field measured data, the ground surface settlement, deflection of retaining piles and wall, internal force analysis of concrete piles, axial anchoring forces, groundwater table, and the deformation of surround building and pipelines were investigated. The results indicates that the combining application of concrete piles, jet grouting columns and anchors support system can effectively control excavation-induced surface ground settlements. The field maximum lateral wall deflections are between 0.o2% and o.19% of the excavation depth due to the competitive site conditions. The bending moment-depth relationship curve is S-type. Groundwater leakage results in the sharp drop in groundwater level, which is part of the reasons for the adjacent building settlement. The axial anchoring forces of the upper layer of anchors increase gradually during the excavation, but those of the lower layer of anchors slightly reduced firstly and then tend to be stable during the excavation procedure. In comparison with the histories of excavation cases, the small lateral wall deflection in this study results from the favorable site condition and the relative rigidity of the retaining structure system.