期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header 被引量:2
1
作者 Dongyi Li zhongguang fu +1 位作者 Qiang Zhang Ting He 《Engineering(科研)》 2013年第1期66-68,共3页
The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentr... The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51. 展开更多
关键词 SUPERHEATER OUTLET HEADER FINITE ELEMENT Method Stress CONCENTRATION