To correct spectral peak drift and obtain more reliable net counts,this study proposes a long short-term memory(LSTM)model fused with a convolutional neural network(CNN)to accurately estimate the relevant parameters o...To correct spectral peak drift and obtain more reliable net counts,this study proposes a long short-term memory(LSTM)model fused with a convolutional neural network(CNN)to accurately estimate the relevant parameters of a nuclear pulse signal by learning of samples.A predefined mathematical model was used to train the CNN-LSTM model and generate a dataset composed of distorted pulse sequences.The trained model was validated using simulated pulses.The relative errors in the amplitude estimation of pulse sequences with different degrees of distortion were obtained using triangular shaping,CNN-LSTM,and LSTM models.As a result,for severely distorted pulses,the relative error of the CNN-LSTM model in estimating the pulse parameters was reduced by 14.35%compared with that of the triangular shaping algorithm.For slightly distorted pulses,the relative error of the CNN-LSTM model was reduced by 0.33%compared with that of the triangular shaping algorithm.The model was then evaluated considering two performance indicators,the correction ratio and the efficiency ratio,which represent the proportion of the increase in peak area of the two characteristic peak regions of interest(ROIs)to the peak area of the corrected characteristic peak ROI and the proportion of the increase in peak area of the two characteristic peak ROIs to the peak areas of the two shadow peak ROI,respectively.Ten measurement results of the iron ore samples indicate that approximately 86.27%of the decreased peak area of the shadow peak ROI was corrected to the characteristic peak ROI,and the proportion of the corrected peak area to the peak area of the characteristic peak ROI was approximately 1.72%.The proposed CNN-LSTM model can be applied to X-ray energy spectrum correction,which is of great significance for X-ray spectroscopy and elemental content analyses.展开更多
X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and...X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and are now receiving increasing attention owing to their superior material flexibility compared with traditional flat-panel detectors.This work aims to study these innovative flexible X-ray detectors in terms of their effectiveness in DR imaging,such as detection efficiency and spatial resolution.To achieve this goal,first,a Monte Carlo model was developed and calibrated to an in-lab 150 kV DR imaging system containing a flat-panel X-ray detector.Second,the validated model was updated with various types of flexible X-ray detectors to assess their performance in nearly realistic conditions.Key parameters such as the detection efficiency pertaining to the crystal material and thickness were studied and analyzed across a broader energy range up to 662 keV.Finally,the imaging performance of the different detectors was evaluated and compared to that of the flat-panel detector in the 150 kV DR imaging system.The results show that the flexible detectors such as the CsPbBr3crystal detector deliver promising performance in X-ray imaging and can be applied to a wider range of application scenarios,especially those requiring accurate detection at challenging angles.展开更多
Metal halide perovskites have recently emerged as promising candidates for the next generation of X-ray detectors due to their excellent optoelectronic properties.Especially,two-dimensional(2D)perovskites afford many ...Metal halide perovskites have recently emerged as promising candidates for the next generation of X-ray detectors due to their excellent optoelectronic properties.Especially,two-dimensional(2D)perovskites afford many distinct properties,including remarkable structural diversity,high generation energy,and balanced large exciton binding energy.With the advantages of 2D materials and perovskites,it successfully reduces the decomposition and phase transition of perovskite and effectively suppresses ion migration.Meanwhile,the existence of a high hydrophobic spacer can block water molecules,thus making 2D perovskite obtain excellent stability.All of these advantages have attracted much attention in the field of X-ray detection.This review introduces the classification of 2D halide perovskites,summarizes the synthesis technology and performance characteristics of 2D perovskite X-ray direct detector,and briefly discusses the application of 2D perovskite in scintillators.Finally,this review also emphasizes the key challenges faced by 2D perovskite X-ray detectors in practical application and presents our views on its future development.展开更多
基金This work was supported by the Open Project of the Guangxi Key Laboratory of Nuclear Physics and Nuclear Technology(No.NLK2022-05)Central Government Guidance Funds for Local Scientific and Technological Development,China(No.Guike ZY22096024)+3 种基金Sichuan Natural Science Youth Fund Project(No.2023NSFSC1366)Open Research Fund of the National Engineering Research Center for Agro-Ecological Big Data Analysis&Application,Anhui University(No.AE202209)Research Fund of Guangxi Key Lab of Multi-source Information Mining&Security(MIMS22-04)National Natural Science Youth Foundation of China(No.12305214).
文摘To correct spectral peak drift and obtain more reliable net counts,this study proposes a long short-term memory(LSTM)model fused with a convolutional neural network(CNN)to accurately estimate the relevant parameters of a nuclear pulse signal by learning of samples.A predefined mathematical model was used to train the CNN-LSTM model and generate a dataset composed of distorted pulse sequences.The trained model was validated using simulated pulses.The relative errors in the amplitude estimation of pulse sequences with different degrees of distortion were obtained using triangular shaping,CNN-LSTM,and LSTM models.As a result,for severely distorted pulses,the relative error of the CNN-LSTM model in estimating the pulse parameters was reduced by 14.35%compared with that of the triangular shaping algorithm.For slightly distorted pulses,the relative error of the CNN-LSTM model was reduced by 0.33%compared with that of the triangular shaping algorithm.The model was then evaluated considering two performance indicators,the correction ratio and the efficiency ratio,which represent the proportion of the increase in peak area of the two characteristic peak regions of interest(ROIs)to the peak area of the corrected characteristic peak ROI and the proportion of the increase in peak area of the two characteristic peak ROIs to the peak areas of the two shadow peak ROI,respectively.Ten measurement results of the iron ore samples indicate that approximately 86.27%of the decreased peak area of the shadow peak ROI was corrected to the characteristic peak ROI,and the proportion of the corrected peak area to the peak area of the characteristic peak ROI was approximately 1.72%.The proposed CNN-LSTM model can be applied to X-ray energy spectrum correction,which is of great significance for X-ray spectroscopy and elemental content analyses.
基金supported by the China Natural Science Fund (No.52171253)Natural Science Foundation of Sichuan (No.2022NSFSC0949)。
文摘X-ray imaging technologies such as digital radiography(DR),is an important aspect of modern non-destructive testing and medical diagnosis.Innovative flexible X-ray detector technologies have recently been proposed and are now receiving increasing attention owing to their superior material flexibility compared with traditional flat-panel detectors.This work aims to study these innovative flexible X-ray detectors in terms of their effectiveness in DR imaging,such as detection efficiency and spatial resolution.To achieve this goal,first,a Monte Carlo model was developed and calibrated to an in-lab 150 kV DR imaging system containing a flat-panel X-ray detector.Second,the validated model was updated with various types of flexible X-ray detectors to assess their performance in nearly realistic conditions.Key parameters such as the detection efficiency pertaining to the crystal material and thickness were studied and analyzed across a broader energy range up to 662 keV.Finally,the imaging performance of the different detectors was evaluated and compared to that of the flat-panel detector in the 150 kV DR imaging system.The results show that the flexible detectors such as the CsPbBr3crystal detector deliver promising performance in X-ray imaging and can be applied to a wider range of application scenarios,especially those requiring accurate detection at challenging angles.
基金This work was funded by the National Natural Science Foundation of China(22279049 and 12247101)the Fundamental Research Funds for the Central Universities(lzujbky-2021-it31,lzujbky-2021-ct15 and lzujbky-2021-sp69)+1 种基金the calculation work was supported by Supercomputing Center of Lanzhou Universitythe Gansu Province Outstanding Doctoral Student Program(22JR5RA435).
文摘Metal halide perovskites have recently emerged as promising candidates for the next generation of X-ray detectors due to their excellent optoelectronic properties.Especially,two-dimensional(2D)perovskites afford many distinct properties,including remarkable structural diversity,high generation energy,and balanced large exciton binding energy.With the advantages of 2D materials and perovskites,it successfully reduces the decomposition and phase transition of perovskite and effectively suppresses ion migration.Meanwhile,the existence of a high hydrophobic spacer can block water molecules,thus making 2D perovskite obtain excellent stability.All of these advantages have attracted much attention in the field of X-ray detection.This review introduces the classification of 2D halide perovskites,summarizes the synthesis technology and performance characteristics of 2D perovskite X-ray direct detector,and briefly discusses the application of 2D perovskite in scintillators.Finally,this review also emphasizes the key challenges faced by 2D perovskite X-ray detectors in practical application and presents our views on its future development.